Question about Electrolux UltraLux 2000 Bagged Canister Vacuum

2 Answers

Stops vacuming quickly after new bag inserted

The vacuum works fine with a new bag in it, but quickly, if the bag is only a 1/4 full, it stops the suction action.

Any solutions?

Thank you,

Joni Sliwoski - Keoniski@aol.com

Posted by on

Ad

2 Answers

There is not a dial on top of the vacuum.

Posted on Dec 29, 2007

Ad
  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Contributor
  • 75 Answers

Is there a dial on the top of the vacuum?

Posted on Dec 29, 2007

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Very low suction when I use the hose, but the carpet brush roller attachment works fine. Any ideas?


This style of vacuum has great airflow but does not have great suction, especially at the end of the hose but it still should have enough to pick up most soils. It may have a restriction in the suction tube or emptor. The disposable bag may be full or clogged, the outer bag could also be clogged.

May 04, 2016 | Kirby G4 Bagged Upright Vacuum

1 Answer

While vacuuming the red light for the bag of the vacuum came on and the vacuum stopped. The bag was no where near full so I replaced it with a new bag - same problem. It vaccumes for a minute or then stops...


I'm assuming this is the Epic 6500 or similar model.
Detach the hose, turn vacuum on. If it runs, place palm of hand against inport hole. If it shuts off the problem is with either the control valve setting or the control valve assembly itself.
For cvs, turn dial on top of vacuum all the way to the largest dot, and try above test again. If that doesn't work, then it's the CVA. It needs to be cleaned or replaced, which is an in shop job. Fro repair, take it to the nearest Aerus Electrolux store. I recommend a full clean and service to remove any dust/dirt from the motor, fan assembly, and other internal parts.

Another problem, which relates to the dial setting, is that fine dust will quickly clog the pores of the bag, resulting in the machine "thinking" the bag is full. Turning the dial to the proper setting helps get the bag fuller. The middle setting is the normal setting, and is for areas without fine dust and sand.

Dec 05, 2010 | Electrolux Vacuums

2 Answers

Model UH60010, Series X12.0, Mfg code K09A. While attempting to use the hose and the extensions to clean shelves, my wife reported no suction. I removed the brush roller and the plastic piece just below...


There are six different reasons a vacuum can lose suction, a plugged vacuum hose, bad motor, full vacuum bag, or cracked or damage hoses. Purchasing a vacuum cleaner can be a costly expense while repairing the suction on the unit can be virtually free. Most suction loss problems on a vacuum can be easily fixed or remedied with common house hold tools and very little technical expertise.
If your vacuum cleaner losses suction, the first and easiest solution is to check the bag. If the vacuum cleaner bag is full suction will be greatly reduced and the unit will become ineffective. A vacuum cleaner works by passing air through the bag fibers leaving dirt and debris behind inside the bag. If the refuse bag becomes full, airflow is restricted, limiting the amount of air passing through the vacuum bag resulting in loss of suction. When replacing the vacuum bag always consult your owners manual to insure that the vacuum bag seals with the vacuum inlet hose. If your vacuum cleaner bag is not tightly sealed to the vacuum inlet hose you will decrease the air flow through the bag resulting in loss of suction.
The second and sometimes most common reason for loss of suction on a vacuum cleaner is a plugged vacuum hose. If the hose becomes plugged, air flow will become restricted. To unplug a vacuum hose detach it from the machine and inspect the inside. If there is a restriction in the hose, remove it with your fingers and replace the hose onto the unit. If the hose is long and the debris is hard to get too, a broom handle or other long object can be passed through the hose to dislodge the debris. Most vacuum cleaners contain more that one suction hose, so make sure to check each one by process of elimination. Another area that can become easily plugged on a vacuum cleaner is under the lower base of the unit by the roller brush. Large debris can get caught in this area and restrict air flow to the hose.
If your vacuum refuse bag is not full and the suction hoses are not plugged the next thing to check is the condition of the hoses. Many hoses are made from plastic which can easily tear or crack. If your vacuum cleaner shows signs of wear or are cracked they need to be replaced. Even the smallest hole in a vacuum hose can leak enough air to greatly diminish the suction potential of your unit. Replace your vacuum cleaner parts with OEM parts from the original manufacturer to ensure the tightest fit.
Most vacuum cleaners contain filters. Filters are used as a last line of defense to remove dust and smaller debris particles before the air is recycled back into the environment. If vacuum cleaner filters become dirty or plugged they also can decrease the amount of air traveling through the unit. Some filters can be easily rinsed with water whereas others need to be replaced. It is important to check your owners manual before rinsing a vacuum filter.
The last and probably least common problem for a vacuum cleaner to loose suction is a bad or failing vacuum motor. Over time vacuum motors lose power due to worn carbon brushes or long term damage. A vacuum cleaners worst enemy is moisture. If water or moisture is sucked into the vacuum motor it will greatly diminish the amount of suction the unit has. Replacing a vac motor can be a costly and time consuming ordeal. In some cases, replacing a vacuum motor can outweigh the cost of buying a new vacuum. Vacuum suction is measured in water lift which can easily be measured by using a water lift gauge. If the water lift measured in inches, falls below half the original water lift specifications for the unit, it is time to replace your motor. Most vacuum cleaner repair shops carry this type of equipment and can easily tell you if it is time for a new vac motor.

Jul 25, 2010 | Vacuums

1 Answer

After we change the bag, it still gives us a red light


Greetings,

The bag full indicator on most vacuum cleaners is not completley fool proof. Most vacuums will just register a loss of suction, and they will then illuminate the bag full indicator, whether or not the bag is full.

If you've changed the bag, and the machine is still indicating a full bag, then this could mean one of two things.

1. Dirty Filter. According to the part diagram for your vacuum, there is a filter underneath of the vacuum cleaner bag (Bissell Part Number
203-1013) that is there to protect anything from getting into the motor. Since the filter is located before the motor, most refer to this as a pre-motor filter. Sometimes if this filter is really dirty, it can cause the vacuum to loose suction, which will also cause the bag full indicator to incorrectly display. Simply clean this filter by running it under warm water, then allow it to completely dry before replacing it in the vacuum. While the filter is out of the vacuum you can turn it back on and test to see if the light is off now that the filter is out. If the light goes off, then you have found the problem! If the bag full indicator is still on, please see the next possible problem.

2. Clog In the Vacuum. If the vacuum was run with a full bag, and when you removed the bag, the bag was completely jammed full, then your vacuum cleaner may be clogged somewhere. When the bag is packed full of dirt, the vacuum continues to try and put more and more dirt in the bag, even if it's full. Sometimes the dirt will even start accumulating inside the hose as it has no other place to go. The first place you should check is the hole that you connect the bag to. Remove the new bag that you installed and examine the hole that the bag connects to inside the vacuum. Can you see anything stuck here? If yes, do your best to try and dislodge it. If you're not able to visibly see anything here, your clog may be inside the hose, or even in the base of the vacuum.

If you have another vacuum cleaner this will really help you in clearing the clog. With the other vacuum, take the suction hose of the good vacuum, and connect it to the hose on your Bissell (still while the bag is removed, and the bag housing door is open). When you connect the hose of the other vacuum, can you hear a difference in the motor? Does the motor start running at a higher pitch when it's connected to your Bissell? If yes, then you've narrowed it down to a clog in your hose. If you can feel suction from the other vacuum through the hole that the bag connects onto, and the good vacuum's motor doesn't change noise when connected to the Bissell, then your clog is in the bottom section of the vacuum. You can sometimes stretch out the hose of the Bissell while the other vacuum is attached, and this will dislodge the clog.

If you don't have another vacuum, simply remove the hose from the Bissell completely. I believe that there maybe 2 screws that hold this hose onto the back of your Bissell, simply remove these two screws, and remove the hose. An easy way you can clear clogs is to take the hose outside, and use a water hose that has a pressurized nozzle on it, and spray down the hose while holding the hose of your Bissell vertically to allow gravity to work its magic. You can also stretch out the hose of the Bissell to get maximum benefit of gravity and the water.

If the clog is in the lower part of the vacuum, it is usually right at the suction port behind the roller brush. This is the most narrow part of the vacuums suction intake in the lower part of the vacuum, and is prone to clogs. Simply remove the four screws on the bottom of your Bissell to remove the bottom plate. Look behind the roller brush to where the suction port is to see if you can see any clogged debris.

If this doesn't help clear your clog, or fix the bag full indicator, I'd really like to try and diagnosis this further with you. Please just use the Clarification Request or add a comment and explain what happend after trying these things I mentioned above. I'll be more then happy to try and assist your further. I really hope that this was helpful to you. If you found this helpful, please be kind and rate my repair by clicking the thumbs up icon in the review.

Thank you very much,

Chris J.

Mar 21, 2010 | Bissell 3522 PowerForce Bagged Upright...

1 Answer

When you put your hand over suction it shuts off and the bag light goes on it acts like the bag is full but its aq brand new bag


So what's the problem? Stop blocking the suction with your hand! The machine can't tell the difference between a blockage caused by your hand and a blockage caused by a full bag. Just be grateful that you've got a machine with such good protection.

Jan 12, 2010 | Vacuums

1 Answer

It wont pick up with a new bag in and it seems to **** back in


Check if there is something stuck in the the suction tube, telescopic wand or in any of the parts involved. I had the same problem due to a number of chocolate wrappers stuck in the wand. I almost went and bought another one, luckily i had the sense to ask the salesman at sears the same question and he put me on the right path. The suction tube and wand are detachable from the unit, so you should be able to unplug the parts and check. This is the same solution if you motor is running fine but you have lost suction and\or bag shows full when it is not. Hope i am saving someone some money by stating the obvious here, just the way the sears salesman helped me.

Nov 07, 2009 | Kenmore Magic Blue 24195 Bagged Canister...

4 Answers

Full bag system works properly, but doesn't reset easily


Either there is something wrong with your switch. Which it doesnt sound like it. Take it to your dealer or call another one it sounds like the control valve needs to be replaced. I am a dealer 1-866-966-9350.

Jun 19, 2008 | Electrolux Lux 7000 Bagged Canister Vacuum

1 Answer

No hose suction with replacement bag


The Bag must be blocking the port it connects to. Remove the bag and close it up. Test it again with no bag in it. If you have suction now, the bag is blocking the port. Maybe it is the wrong type, or installed wrong.

Feb 24, 2008 | Kenmore 28075 Bagged Canister Vacuum

Not finding what you are looking for?
Electrolux UltraLux 2000 Bagged Canister Vacuum Logo

Related Topics:

83 people viewed this question

Ask a Question

Usually answered in minutes!

Top Electrolux Vacuums Experts

Les Dickinson
Les Dickinson

Level 3 Expert

18429 Answers

Marvin
Marvin

Level 3 Expert

83096 Answers

Chris Nomland
Chris Nomland

Level 2 Expert

115 Answers

Are you an Electrolux Vacuum Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides