We have a goodman clj42-1 air compressor and the fan on top of the outside unit is not running. It is making a humming noise when it is turned on. Any solutions?
Comments:
Oct 10, 2009
- Thanks for helping with the advise to lubricating the fan. We have the fan running but the air is still not cool coming out of the vents. Any additional suggestions?
Fan motor is dry or going bad try to lubricate it and see if that frees it up. If not you will need to get a new fan motor.
Comments:
Oct 11, 2009
- I think you may have lost your refrigerant, you should be able to see this gauge it will be a small circle with a green dot in the middle, if you see bubbles on the gauge or nothing at all, you are low. you can check to see if you have or try to find the leak yourself with some dish soap in a squirt bottle and spray on all the copper pipes inside the unit this has to be done when it is running, As for the refrigerant you will need to have someone who is certified to recover& administer it for EPA issues.
I have power to the main, air handler breaker, and tothe compressor disconnect, but nothing is...
(More)
I have power to the main, air handler breaker, and tothe compressor disconnect, but nothing is coming on.
Add the things you own to your My Products collection and get product information, solutions to problems, manuals & guides, tips and how-to's, reviews & ratings and local repair service - all in one easy place.