I have both a tornado and a C3. I am getting a F2 low temp reading on one and a low mag reading on the other. I bought the tornado used and have pretty much had the entire insideds rebuilt within the last 10 months and the C3 is only 4 months old! I clean out the vents and the crumb catchers weekly and I can't afford to poor any more money into them! HELP! I will fix it myself if I knwo how!
for the f2 low temp verify the high-limit thermostat is not tripped. inspect the mags, make sure they are not loose. Also try inspecting the ir element washer look for corrosion or signs of arching. Is your wave cover damaged or missing. Sorry to say this generally is a factory trained fix because its usually because of an rf leak