APC RS 900. Intermittently the yellow battery light will come on for only a second or so, long enough to get one beep, maybe. Been on the phone with APC tech and they had me lower the sensitivity to medium. Still having problems. Worse, they techs must be outside US as they are very difficult to understand. Still under warranty.

Posted by on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
jvpacoin
  • 91 Answers

SOURCE: Overload light in APC RS 800 UPS

it seems that the inverter circuit of your UPS is dying. the solution here is you have to open up the UPS and check the inverter circuit. to make easier, check the power mosfet if its leaking.

Posted on Aug 14, 2009

Ad
  • 773 Answers

SOURCE: APC Back UPS RS-1000 Overload LED with beeping sound after on.

this indicates you have too many things plugged into it.

Posted on Nov 20, 2009

pravinbhavsa
  • 348 Answers

SOURCE: how to use apc rs 900 without battery

No no way to use the ups without battery it will not show mains supply without battery and you cannot use it as a stabilizer you must connect battery

Posted on Mar 10, 2010

  • 84 Answers

SOURCE: My APC RS 900 UPS is making a beeping noise and

Without knowing which light is flashing I can only guess. From my experience and assuming it is the battery light that is lit and NOT the overload light, it can be one of two things, one is your battery is near the end of its life and needs to be replaced, and the other is that your battery is improperly connected.

To confirm if your battery needs to be replaced or not, you can run a self test. Ensure that the battery has had time to fully charge (and that it is definitely correctly connected), and then turn off the UPS, and turn it back on. It will automatically run a self test.

if the light stays lit, you need to order new batteries. One source is here: http://www.refurbups.com/APC-Back-UPS-RS-900-BR900-Replacement-Batteries

If it IS the overload light that is lit, you simply have too much equipment attached to the UPS, more than the inverter can handle. Try removing some equipment until it turns off.

Posted on Mar 31, 2010

BarrettDenCo
  • 1772 Answers

SOURCE: I just replace the battery

Sorry to read about your problem, I hope this helps you out.

let it charge 24 hours, and see if it works

I tried to help you. Please help me and Rate/Vote on my response, thanks and good luck

Posted on Dec 22, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Apc beeping twice every 2 seconds


The battery inside the APC is "weak", and the "beep" is telling you to replace the battery inside the APC, or, maybe cheaper, to buy a new APC.

Feb 03, 2014 | APC BACKUPS ES BE550G 8Outlet 550VA 330W...

2 Answers

I just replace the battery in my APC RS 900 unit because the red indicating light was telling me to do so. I installed the new battery and the red indicating light is still telling me to replace the...


Sorry to read about your problem, I hope this helps you out.

let it charge 24 hours, and see if it works

I tried to help you. Please help me and Rate/Vote on my response, thanks and good luck

Dec 22, 2010 | APC Back-UPS RS 800VA UPS System

1 Answer

Rs 900 back up is beeping with the on battery, overload, and replace battery lights blinking


just check that you are not overloading the ups or make sure that the ups output is not connected to the input of the ups in most of such cases almost all light indicators start blinking

Dec 04, 2010 | APC Back-UPS XS900 (BX900) UPS System

3 Answers

My APC RS 900 UPS is making a beeping noise and the red light on the front is blinking. It seems to be working, but what is it trying to tell me?


Without knowing which light is flashing I can only guess. From my experience and assuming it is the battery light that is lit and NOT the overload light, it can be one of two things, one is your battery is near the end of its life and needs to be replaced, and the other is that your battery is improperly connected.

To confirm if your battery needs to be replaced or not, you can run a self test. Ensure that the battery has had time to fully charge (and that it is definitely correctly connected), and then turn off the UPS, and turn it back on. It will automatically run a self test.

if the light stays lit, you need to order new batteries. One source is here: http://www.refurbups.com/APC-Back-UPS-RS-900-BR900-Replacement-Batteries

If it IS the overload light that is lit, you simply have too much equipment attached to the UPS, more than the inverter can handle. Try removing some equipment until it turns off.

Mar 18, 2010 | APC Computers & Internet

1 Answer

How to use apc rs 900 without battery


No no way to use the ups without battery it will not show mains supply without battery and you cannot use it as a stabilizer you must connect battery

Mar 09, 2010 | APC Back-UPSĀ® XS 900 (BX900R) UPS System

1 Answer

After a power outage my apc has this clicking sound. every 4 seconds or so it sounds like it clicks and then a slightly different click 4 seconds later. However, when everything is powered up it doesn't...


I found this on the APC website;
Question: What would cause a Back-UPS Pro, a Back-UPS Pro USB, a Back-UPS RS, a Back-UPS CS, a Back-UPS LS, or A Back-UPS XS to beep once every 5 seconds with no output power?
Answer: One beep every 5 seconds is an indication that the UPS has entered what is called "Low Voltage Sleepmode".
The Back-UPS product has transferred to battery power due to a low voltage condition at the wall. The Back-UPS has remained Onbattery until its runtime was totally exhausted, however, there was still enough voltage present at the wall to trickle charge the battery.

This is considered to be a normal operating state. When the voltage returns to normal the Back-UPS will wake up and restore power to the battery outlets.

Nov 02, 2009 | APC Back-UPS ES 350 - UPS ( external ) -...

1 Answer

Overload light in APC RS 800 UPS


it seems that the inverter circuit of your UPS is dying. the solution here is you have to open up the UPS and check the inverter circuit. to make easier, check the power mosfet if its leaking.

Jun 11, 2009 | APC (br800) UPS System

2 Answers

Beeping error


on the heatsink thats in front the fans theres six fet irfb23n20d mine had the outer two towards the fan short circuited.replaced them and all is well now.

Oct 24, 2008 | APC Back-UPS RS Battery Backup (apw...

Not finding what you are looking for?
Computers & Internet Logo

Related Topics:

134 people viewed this question

Ask a Question

Usually answered in minutes!

Top APC Computers & Internet Experts

Cindy Wells

Level 3 Expert

5187 Answers

Jax Planet
Jax Planet

Level 2 Expert

922 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Are you an APC Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...