I have a ingersoll rand air compressor rand 4000 60 gl vertical 230v model #ra5e6va serial #dc90177-0025 i am wanting to know what cylinder head torqe is for the compressor.the head gasket leaks oil and can see air bubbling in oil

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 1,167 Answers

You dont torque it you can torque it ya self if you wont but wont make a change do it to 40-50nm ahd try this if no good replace the gasket they do wear out at times also when you take the head off thereshouldnt be oil in there only on the cyclinder not the head ??

Posted on Oct 08, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have old Ingersoll Rand compressor type 30 model 15T serial # 243496 Blow fuss when restart ?


Probably a faulty non return check valve, when the unit reaches pressure air in the delivery pipe is vented down at the pressure switch. If the check valve is passing back this will cause the unit to try to start against a pressure causing it to pull high amps and trip. If there is a constant hiss coming from the pressure switch when the unit stops it will be the non return valve. There should be a short hiss of air when units stops If there is no hiss at all when the unit stops it could be a faulty pressure switch. If it is a quick fix would be to create a small leak on the delivery pipe to vent the line down.

May 28, 2014 | Ingersoll Rand - Rand Type - 30...

1 Answer

Whare can i get picture of ingersoll rand type 30 model 234 with serial no 645261


Hi Omran,
The capacity of your compressor is 7.46 if the motor drive is 2 hp. 9.79 if the motor drive is 3 hp.


Hope i can help you.

Sep 13, 2012 | Ingersoll Rand - Rand Type - 30...

1 Answer

I have a 80 gallon 5 hp ingersoll model #2475N5 serial #30T900896. Im using 10-3 wire on 40amp doible pole breaker. as its building air when it hits @50 psi it slows down. if I pull the pop off valve on...


T wo suggestions. 1- check the check valve located in top of the receiver tank by letting the unit pump up to 50 psi. shut it off and loosen the copper tube at the HP cylinder. if no air blows out the check valve is good. If it's bad it will blow until it empties the tank. If the check valve is bad replace it. 2- Tighten the drive belt. If neither corrects the problem remove the guard and rotate the pump by hand. If it's hard to rotate you have a pump problem.

May 08, 2011 | Ingersoll Rand Ingersoll-Rand 80 gal. Air...

1 Answer

Wiring diagram for 230v


Single phase motor for 230V, connect T4 and T5, to one line. T2, T3, T8 common connected. T1 to other line. Check Rotation, This should be for CCW rotation facing output shaft. Swap T5 and T8 for CW rotation.

Jan 17, 2011 | Ingersoll Rand TS4N5 Ir Electric...

1 Answer

I have an Ingersoll Rand compressor (RA5E6VA) 5 HP 60 gal vertical tank (only found 3 HP listing below, but it says 5 HP on it) There is a plastic tube between where the pump attaches to the tank (air in)...


that is just a compression fitting. Sometimes just replacing the tubing is enough to get a bit on it. If not you should be able to get another fitting from an indstrial supplier.

Mar 06, 2010 | Ingersoll Rand Single Stage Cast Iron 3 Hp...

1 Answer

Wiring installation for ss5l5 IR 5hp 60 gallon compressor


A #10AWG wire can be use and 40Amp breaker can be use also. Your 5hp/230V/1/60hz motor amp is 30A.

May 30, 2009 | Ingersoll Rand SS5L5 Ir Electric...

Not finding what you are looking for?
Ingersoll Rand Type 30 Electric Driven Two Stage Horizontal Air Compressor 120 Gallon Fully Packaged Ir 2545E10VFP Logo

1,151 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ingersoll Air Tools & Compressors Experts