Pressure switch problems

Pressure switch problem,blinks 3 times so i replaced pressure switch,board and ignator but borad still blinking 3 times and furnace wont turn on.

Posted by on

Ad

2 Answers

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Habit-Forming:

    Visited the website for 3 consecutive days.

    Filmmaker:

    Uploaded 5 video answers.

  • Expert
  • 117 Answers

Yes, check for obstructions. However, also check to ensure that you used an OEM pressure switch! See this video for an explanation: Amazon Furnace Parts: http://www.amazon.com/s/?_encoding=UTF8&camp=1789&creative=390957&field-keywords=gas%20furnace%20parts&linkCode=ur2&tag=amznelite-20

Posted on Mar 04, 2015

Ad
  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Governor:

    An expert whose answer got voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 80 Answers

This is a air proving problem. You need to check your flue for obstructions like birds nests, rodents, snow, ice, etc. The inducer motor creates a draft that is proved by the pressure switch. This will not make if there is a restriction somewhere.

Posted on Oct 07, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Indicator blicks 3 times replaced combustion air switch but did not resolve problem. what do i do now?


There should be a diagnostic chart on the furnace door by the wiring schematic. If so see what the code reads for three blinks.
By the term "air combustion switch" I guess you are referring to the pressure switch. Most diagnostics blinking three times is just a dirty flame sensor. If this is the case the burners will light and go out within 4 seconds. If this is the problem carefully remove the flame sensor and clean gently with emery cloth, fine sandpaper or fine steel wool. Reinsert the sensor and enjoy your heat.

Feb 14, 2014 | Coleman 7990-319p Evcon Gas Furnace...

1 Answer

Furnace problems


On - OK
1 Blink - Ignition failure. Check Gas flow, gas pressure, gas valve, flame sensor.
2 Blinks - Closed pressure switch. Check pressure switch (stuck in closed position).
3 Blinks - Pressure switch - failre to close. Check venter, pressure switch, vent blockage.
4 Blinks - Open limit switch. Main limit or aux limit are open. (My comment - Means overheating in chamber. Often result of blocked intake air. Bad filter. In my case, plastic wrap had been sucked into the intake. )
6 Blinks - False flame sensed. Check sticking gas valve.
Rapid continuous blinking - Incorrect twinning, incorrect primary polarity. Reverse transformer secondary leads, reverse primary wires.

Closed pressure switch can be from dirty combustion vents, bad chamber pressure - like missing screws, maladjusted gas pressure, failing pressure switch, loose hoses, moisture in the hoses or fan blades The switch need to be closed to ge the unit to work

Jan 23, 2008 | Goodman GMS90703BXA Heater

1 Answer

Protech 62-24084-02 troubleshooting


62-24084-02 LED CODES
POWER LED - GREEN
ON - Normal
OFF - No power to board
OK LED - GREEN
One Blink - One hour retry delay
Two Blinks - Pressure switch failure (remains open)
Three Blinks - Limit switch fault
Four Blinks - Pressure switch failure (remains closed)
Five Blinks - Twinning fault
FLAME LED - YELLOW
ON - Good flame
Rapid Blink - Flame present with gas valve de-energizing
Slow Blink - Marginal flame

Jan 01, 2014 | Protech Rheem/62-24084-82-1PK - Integrated...

1 Answer

Stanby/timer button is blinking red and doesn't turn on? (9 blinks then pause then 9 blinks continuously)


Hello
Your TV has fault in the oiwer regualtor board. As it is intermittent 9 blinks means some times your TV is gettin on, an other times flashinig. There is some fault to the switching regulator on the "G" borad or its connections.
If you intent to do it by yourself, take all necessary precations when we work with an electrical equipement. Keep children away from you, and never let them even stand beside you. Let an adult beside you before you open its back cover. Pull out the power chord of your TV frm wall socket to isolate it from mains supply. Stand on any non conductive meterial spread on the floor, or wear shoes made of rubber or plastic. Don't use any metal chair.
Normally switching regulatror can be located on the "G" board of Sony sets. Sometimes in your set, the location may be different. Anyway locate the power regulator board. Pull it out, and examine whether there is any loose solderings in it or not, especially to the solder legs of the STR. Resolder its joints and suspected dry soldered joints.
Power on the set. If this does not help, you should replace the STR [Switching Regulator Transistor], fitted on that boar. It will be screwed to a metal heat sink. Unscrew and desolder it out from the board, and go for the same type and number, replace it. Ok
As much as 28KVDC [28,000C volt DC], points are there in your TV while it works. It is dangerous to touch. You must be very caucious.
Wish you sucess.

Oct 23, 2010 | Sony FD Trinitron WEGA KV-32HS420 32" TV

1 Answer

Blinks on and off 3 times but will not come on


Look on the Deflection Board for Bad Capaciotrs they will be Vented ,swollen or Puffed up on Top. CP150 2200uf 16v use 25v and CP114 CP120 220uf 35v or 330uf 35v,Resolder all the Pinns on the FBT flyback Transfomer.

Deflection borad is bottom board on left hand side,Right hand side is the SSB signal board.

Oct 04, 2010 | RCA D52W20 52" Rear Projection HDTV-Ready...

1 Answer

I have a Goodman GMPN080-4 furnace. The light on the board blinks 3 times. The furnace won't light at all. What could be the problem?


Hi 3 blinks should mean it is the pressure switch there should be a code in the manual or inside of the door

Jan 30, 2010 | Goodman Heating & Cooling

1 Answer

The led light blinks 3 times then pauses then


Pressure switch error code, Check the air filter for blockage, check the vent pipes for blockage or water, make sure the condensate drains are working and that there is no water in the hose(s) that go to the pressure switch(s).

Jan 06, 2010 | Goodman GMS90703BXA Heater

1 Answer

Goodman GDS80904BNA LED Blinks 3 Times


had similar problems with same furnace. I think the 3 blinks is high limit event. either way with the power off to the furnace remove the board from the 4 clips holding it on one at a time then turn it over and look at it you will be able to tell if the board is bad because it will appear scortched and the resin will be bubbled up where it went bad. replace board and you will be fine. went through 2 in 2 years all of a sudden they are being made by a different company from the original and the 1st replacement. now all is fine. Take a good picture of the board close up so you can reconnect all the wires properly. Friend of mine got it from a wholesaler for $55.00

Dec 12, 2009 | Goodman GMS90703BXA Heater

1 Answer

TV cant be switch on, RED LED diagnostic Blinks .. 3 times... then 4 times. Please advise probable cause and send sTV hcematic diagram.


Hi, this is main board failure and you will need to replace this vital board. you power board is fine but, it is unable to send a proper current through the main mother board due to the damage at hand.

May 21, 2009 | Sony KV-29FX30 29" TV

3 Answers

Circuit board light blinks 3 times heater will not turn on


The error code refers to a defective combustion air switch. Coleman Evcons made around 2007 had defective pressure switches or as they call them "combustion air switch". Replace it and the problem is gone.

Dec 13, 2008 | Goodman GMS90703BXA Heater

Not finding what you are looking for?
Goodman GMS90703BXA Heater Logo

275 people viewed this question

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Paul Carew

Level 3 Expert

2550 Answers

Brandon Berry
Brandon Berry

Level 2 Expert

407 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...