Question about Dryers

1 Answer

MY husband replaced coils on top of gas valve. He

MY husband replaced coils on top of gas valve. He turned on dryer & it worked! So he started to put the bottom cover on and hit it(dryer was still on) to close it. The whole dryer stopped working & when we push a button it goes off. tried uplugging for awhile. Got it to start again and after about 1 min. it completely shut off. It's digital and the model # 97195500. Please help. We are a large family and really need it working A.S.A.P.. Thank you D. Flanigan

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 1,922 Answers

Is it completely dead now or does some things still operate??? and what make is the dryer?

Posted on Oct 09, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The Kenmore 110 87880800 gas dryers starts up, ignites the gas initially, then 15 min later the dryer stops heating but continues to turn the drum. If we let the dryer sit for 20 min and turn it back on,...


Hello,
Your dryer is heated by gas and what is happening is,when the coils that open the gas valve work when they are cool but once the dryer is running and the gas valve coils get warm they wont work,this is pretty typical of a bad gas valve coil.Replacing the coils will fix that.To replace the gas valve coils,UNPLUG THE DRYER, use a putty knife and place in the seam between the main front panel and the small lower front panel AT the corners and depress the clip that holds small panel to main panel.On the right side of the base frame behind the small panel is the burner asm. the coils are held to the gas valve by a bracket remove that bracket and replace the coils, they are black round shaped and one has 2 wires and one has 3 wires the plugs pull off and can be push onto the new coils with just a small amount of pressure.
The part # for the coils is 279834 They can be purchased at your local appliance parts store or online at;
apdepot.com
searspartsdirect.com
repairclinic.com
appliancepartspros.com
assuredparts.com

I hope i have helped you to be able to repair your dryer,
Gene

Aug 07, 2011 | Dryers

1 Answer

My gas dryer is 3 years old and it starts to heat up when it is turned on and then stops heating while running.


This is usually due to the two gas valve solenoid coils sitting on top of the gas valves, one with 3 prongs and the other has 2. The coils work fine when cool but one or both are weak and fail when get heated. Both coils must work to open the two gas valves in order for the dryer to fire up. The coils are not repairable and the only viable solution is replacing both of them. Replace the solenoid coils and it should solve the problem.

Feb 28, 2011 | Amana DLG330RAW Gas Dryer

1 Answer

Dryer spins,screen clean,exhaust open blows good no heat


Check the coils on valve or the igniter. Access both thru Access panel on lower right of front panel. Set heated dry cycle & start, igniter should glow bright followed by a "Click" sound, which is valve opening. If it glows and no click, replace the valve coils (2 donut looking objects on top of valve). If no glow, replace igniter, usually just unplug to remove, carefully, they are ceramic and break easy.

Feb 13, 2011 | Maytag MDG2600BWW Gas Dryer

1 Answer

Dryer starts the fire but after a moment it stops


This is a clear indication of a gas valve solenoid coil failure. One or both of the gas valve solenoid coils work when cool but fail when they get hot. These coils are located sitting on top of the gas valve assembly, one with three prongs while the other has two.

Replace both coils and it should address the problem. Remove the front panel then the bracket securing the solenoid coils and then pull the coils out. Slide the new coils in then secure them with the bracket. Indicate the complete and exact model number of the dryer for detailed and complete replacement procedure.

Click on the link below then check if it applies to your dryer.

http://www.fixya.com/support/t5689834-need_replace_valve

Aug 22, 2010 | Dryers

2 Answers

Gas burner won't stay lit


The heat sensor will need to be replaced

Apr 03, 2010 | Dryers

1 Answer

Mdg 4000aww turns on and heats when started. runs for 5 five minutes then flame goes out. ignitor glows but no flame. one minute later dryer still running ignitor glows, no flame. this repaets until turned...


Either the venting needs cleaned or the coils on the gas valve are bad. Unhook the venting from the back of the unit and run. If works ok then clean venting. If you still have the problem, replace the two coils on top of the gas valve.

Sep 29, 2009 | Maytag Neptune MDG5500AW Gas Dryer

1 Answer

Our amana gas dryer. runs for about 20 mins and shuts off. try to resart and there is busing noisefrom the controls on top. if sets for 45mins. it will start again. until it gets hot. and then wont work.


The problem is in the gas valve coils. They sit on the top of the gas valves. When these coils are energized open the gas valves and allowing the gas to burn. If one or more coil malfunctions, the dryer shuts off. It is usually difficult to properly test the coils and replacement is the best solution.

Sep 25, 2009 | Amana Dryers

1 Answer

How to replace gas coil valves on Whirlpool LGR5636EQ3 Gas Dryer


DOES YOUR DRYER HAVE THE LINT SCREEN ON THE TOP? IF SO, REMOVE THAT AND TAKE TWO SCREWS OF(CARE NOT TO DROP IT INTO THE VENT). PULL THE TOP PANEL TOWARD YOU LITTLE BIT AND LIFT UP, THERE WILL BE TWO 5/16 SCREWS INSIDE FRONT PANEL, REMOVE AND UNPLUG THE LID SWITCH CONNECTOR, FRONT PANEL WILL COME OUT. THE GAS VALVES AND COILS ASSEMBLY WILL BE ON THE BOTTOM RIGHT. UNPLUG AND TAKE THE SCREWS OFF THE BRACKET AND REPLACE COILS. CHECK FOR CONTINUITY ON COILS, IT SHOULD READ 1.3 TO 1.9 OHMS. THE ONE WITH THREE TERMINAL, CHECK OHM FROM MIDDLE TERMINAL TO OUTSIDE TERMINALS.

BOYNISMO@YAHOO.COM 714-334-1998.

Aug 21, 2009 | Whirlpool LGR5636L Gas Dryer

1 Answer

Dryer burner just stopped working. the motor turns but no heat. It also will not start on timed heat.


HI, i recommend inspecting all areas stated below to address this issue. the most common problem will be a set of defective gas valve coils but, i suggest checking all points before replacing the coils.


1. Gas valve coils
igniter glows, then shuts off without igniting gas - the problem is probably with defective coils (black, located on top of the gas valve). It is recommended to replace all coils (usually two or three) if found defective.

Note: Sometimes the whole gas valve may be defective, thus not letting the gas out. However, this problem is not common.

2. Thermal fuse
Most dryers have a thermal fuse, which burns out when the dryer overheats, in which case the dryer will either not run at all or stop heating. The fuse is usually located on the vent duct, inside the dryer. A blown fuse will show no continuity when measured with a meter. Before replacing the fuse, make sure the blower wheel is not broken or clogged, and there is nothing blocking the venting.

Note: It is recommended by most dryer manufacturers to replace a hi-limit thermostat when replacing a thermal fuse.

3. igniter
igniter may burn out or break. Replace the igniter if found defective.

Note: Igniters are very fragile and break easily. It is recommended to handle the igniter only touching the ceramic part of it (usually white in color).

4. Flame sensor (or radiant heat sensor)
Replace the sensor (located near the igniter) if found defective.

Jun 18, 2009 | Maytag Neptune MDG5500AW Gas Dryer

1 Answer

Kenmore dryer ( gas )


camaro Most likely the problem is bad gas valve coils located on the top of the gas valve . Unscrew the two screws holding the coil bracket and replace the coils. The part number for the Whirlpool gas valve coils is 279834. Good luck Gendos, post back

Jun 26, 2007 | Kenmore 62882 Electric Dryer

Not finding what you are looking for?
Dryers Logo

Related Topics:

64 people viewed this question

Ask a Question

Usually answered in minutes!

Top Dryers Experts

yadayada
yadayada

Level 3 Expert

76846 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Brad Brown

Level 3 Expert

16194 Answers

Are you a Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides