Question about Amcor AF9000E Portable Air Conditioner

Open Question

I need a fan motor for my Amcor D450 dehumidifier. Any supplier in uk?

Posted by on

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 117 Answers

SOURCE: AMCOR SD10 Dehumidifier, Need to replace the electric fan motor.

Take it out, and search the part number on line, they are bout $40 with s/h. however my current discovery:
It made no sense to me that despite no visual issues, the fan motor is bad. So, with further research it turns out that the true culprit is the small thermistor/thermal fuse between the orange wire (ground) and motor winding wire. The thermistor is taped underneath the silver aluminium and yellow tape on the fan motor. I heard about this bad (open/no continuity) thermistor makes almost >99% of the fan motor problem regardless of any brand name because this cheap c-fram fan motor is NOT made in USA. I opened the motor, there is a silver (aluminum wrap) around the windings for the motor that needs to be cut. Careful not to cut the motor windings. Inside there is a thermistor or type of temperature sensor connected between the orange wire and a motor winding wire. On my motor this was no longer working.
The part marked "JET 123 NM1 2A 130C" is a thermal fuse. The 130C is the temperature rating. When the motor get hot (130C / 265F) the fuse opens. The circuit is broken and the motor stops.

The motor is still good. The fuse is blown. It must be replaced to get the motor running again. You could bypass the fuse but then you invite a fire hazard.

A replacement fuse is available from Digi-Key. It is a Cantherm SDJ1 DF128S (128C):
http://search.digikey.com/scripts/DkSearch/dksus.dll?Detail&name=317-1133-ND

Part cost 98 cents

You might want to go with the next higher temp (141C):
http://search.digikey.com/scripts/DkSearch/dksus.dll?Detail&name=317-1134-ND

Posted on Jan 05, 2010

  • 4736 Answers

SOURCE: fan not operating, believe the

Unfortunately, you will be hard pressed to find parts for your Amcor Dehumidifier. This British Manufacturing Company of electrical household goods went out of business 03/11/2009. Although, there are some of their appliances are still on the market, you can rest assured their warranty is useless.

I wish I had better news for you, but it is what it is. Thanks for choosing FixYa.

Posted on Sep 19, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Filter frozen


This can typically be caused by two items, low refrigeration gas or insufficient air flow. I would shut the unit down, unplug it and let it set for a day to thaw out. Clean all the air passages and replace the filter. Plug it in and turn it back on. If it continues to freeze you probably have either low refrigeration gas or a fan that is not operating properly.

Feb 17, 2014 | Amcor Dehumidifiers

1 Answer

Fan not operating, believe the mother board needs replacement, where could I purchase one for Amcor Dehumidifier Model # AHD-65E


Unfortunately, you will be hard pressed to find parts for your Amcor Dehumidifier. This British Manufacturing Company of electrical household goods went out of business 03/11/2009. Although, there are some of their appliances are still on the market, you can rest assured their warranty is useless.

I wish I had better news for you, but it is what it is. Thanks for choosing FixYa.

Sep 19, 2011 | Amcor Dehumidifiers

1 Answer

Where can i get a motor for an amcor s-320 dehumidifier


Billyboy, if you live in the UK, contact Armcor at +44 20 8560 4141.

If you live in the USA call 1-201-460-8100

They should be able to help you.

Hope this helps you.

May 18, 2011 | Amcor Dehumidifiers

1 Answer

I have a Amcor DC830H and have lost the operating instructions . Could you please inform me as to what lights should be showing when using the dehumidifier part. Thank you


I have a Amcor DC830H and have lost the operating instructions . Could you please inform me as to what lights should be showing when using the dehumidifier part. Thank you

Nov 16, 2010 | Amcor DC930 Dehumidifier

1 Answer

My Amcor AHD 45E dehumidifier sounds like it's running, but it doesn't extract any water






Hi,


There are many reasons why a dehumidifier will not work or collect water.


Here is a tip that I wrote to help people to figure out what is going wrong with their dehumidifier

Dehumidifier is running but no water is in bucket

heatman101


/////////////////////

Oct 13, 2010 | Amcor AHD45 Dehumidifier

1 Answer

Amcor DC800 -dehumidifier- no water collects


Hi,
There are many reasons for a dehumidifier2_bing.gif to not work or collect water.
Here is a tip that I wrote to help people to figure out what is going wrong with their dehumidifier2_bing.gif.

Dehumidifier is running but no water is in bucket
http://www.fixya.com/support/r4662409-dehumidifier_running_but_no_water_in

heatman101

Feb 25, 2010 | Dehumidifiers

1 Answer

AMCOR SD10 Dehumidifier, Need to replace the electric fan motor.


Take it out, and search the part number on line, they are bout $40 with s/h. however my current discovery:
It made no sense to me that despite no visual issues, the fan motor is bad. So, with further research it turns out that the true culprit is the small thermistor/thermal fuse between the orange wire (ground) and motor winding wire. The thermistor is taped underneath the silver aluminium and yellow tape on the fan motor. I heard about this bad (open/no continuity) thermistor makes almost >99% of the fan motor problem regardless of any brand name because this cheap c-fram fan motor is NOT made in USA. I opened the motor, there is a silver (aluminum wrap) around the windings for the motor that needs to be cut. Careful not to cut the motor windings. Inside there is a thermistor or type of temperature sensor connected between the orange wire and a motor winding wire. On my motor this was no longer working.
The part marked "JET 123 NM1 2A 130C" is a thermal fuse. The 130C is the temperature rating. When the motor get hot (130C / 265F) the fuse opens. The circuit is broken and the motor stops.

The motor is still good. The fuse is blown. It must be replaced to get the motor running again. You could bypass the fuse but then you invite a fire hazard.

A replacement fuse is available from Digi-Key. It is a Cantherm SDJ1 DF128S (128C):
http://search.digikey.com/scripts/DkSearch/dksus.dll?Detail&name=317-1133-ND

Part cost 98 cents

You might want to go with the next higher temp (141C):
http://search.digikey.com/scripts/DkSearch/dksus.dll?Detail&name=317-1134-ND

Dec 30, 2009 | Amcor Dehumidifiers

1 Answer

Where, in the UK, can I obtain Amcor replacement parts?


the thermal break is there for a reason, the motor has overheated, if this was due to a towel or other item covering the unit great remove the the obstruction and replace the thermal break. however the major cause is that the bearings have dried up on the motor and it has started to seize, which means replacement.

Mar 31, 2009 | Amcor MD250 Dehumidifier

Not finding what you are looking for?
Amcor AF9000E Portable Air Conditioner Logo

Related Topics:

155 people viewed this question

Ask a Question

Usually answered in minutes!

Top Amcor Heating & Cooling Experts

AJMAL KHAN

Level 2 Expert

382 Answers

Donni Steen

Level 3 Expert

659 Answers

Michael Youngman
Michael Youngman

Level 2 Expert

156 Answers

Are you an Amcor Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides