it has been working fine, i put a load in to dry last night and this morning it was still we. no error message . the inside light is on, but the panel lights are faint but .wont start or reset or anything.....
This is a very common problem with this dryer. It could be one of three things. List below is in order of probable cause: 1.) Bad connection between the interface & Control boards. 2.) Interface board. (Front Bezel with all the buttons) 3.) Control board. (under metal cover top left side of unit) If it was me unplug unit. Remove 3 each screws on back of unit that hold the top on and remove top. Remove screws and open silver box on top left side. With a small screw driver carefully push in on lock tab and pull 2 each flat cable assembly from control bd. Remove silver crossbar at the top near the from 2 screws. Open door pull out and up on front input display bezel carefully. Same process as before remove all cables and reinstall them back in there original location. Then reassemble in reverse order. Turn power on this should fix the problem. If it does not then replace the interface board if that does not work then the control board. me.
Was this helpful?
Yes
No
Popular Solutions for Whirlpool Duet 7.0 Cu. Ft.
Whirlpool Duet 7.0 Cu. Ft. 10-Cycle Super Capacity Plus...
Add the things you own to your My Products collection and get product information, solutions to problems, manuals & guides, tips and how-to's, reviews & ratings and local repair service - all in one easy place.