Question about Intermatic & Indoor/Outdoor Rain Tight Timer

1 Answer

I have an intermatic T101 and the trip pin broke off. Can I replace the tripper or do I have to buy an new unit?

Posted by on

  • Anonymous Mar 15, 2014

    the replacement pin on the off side jams

×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 986 Answers

You may be able to rig it up. They dont sell parts for these. If you can jury rig it just get a new one

Posted on Sep 12, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have the Paragon 4001-00 timer. The timer seems to be working okay as far as time and trippers are tripping however it doesnt seem to be engaging our secutiy door lock for the night. Could the conrt


Does the manual override lever move back and forth as trippers pass? If NO, then trippers are bad
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000
http://www.amazon.com/dp/B00441YVCO/?tag=waterheaterti-20

120 Volt timer.
When timer is ON, test across terminals 2 and 3 for 120 Volt
If 2 and 3 show 120 volt, then timer is delivering power on schedule. Look for loose connections. Loose wire nuts.
If 2 and 3 do not show 120 Volt, then timer has failed.
Suggest buy T101 as replacement for durability and generic replacement parts.
http://waterheatertimer.org/Buy-T100-series-timers.html

Crossover wiring from Paragon 4001-00 to Intermatic T101
Paragon 1 to Intermatic 1, Paragon 2 to Intermatic 2, paragon 3 to Intermatic A

Nov 05, 2014 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

My timer works fine but I need to buy extra trip pins so that I can turn my waterfall off for three hours at a time. Where can I buy extra trip pins?


Timer is not identified.
Copy following links for intermatic timers, and trippers:
http://waterheatertimer.org/Intermatic-timers-and-manuals.html
http://waterheatertimer.org/Intermatic-trippers-and-parts.html#trippers

Jul 16, 2012 | Hardware & Accessories

1 Answer

I need trippers for timer paragon 4001-00m


1) Paragon is no longer making X2772 trippers for the 4000 series timer.
Some places may still sell the X2772 tripper.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

2) I saw X2772 trippers for $60 spring 2011. And the ad did not say the trippers were new.

3) Buy replacement T101 Intermatic timer for less than that.
Example at Amazon showing T101 indoor timer: For outdoor timer, buy T101R.
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

4) Crossover wiring from Paragon 4001-00 to Intermatic T101:
Paragon terminal 1 goes to Intermatic 1
Paragon terminal 2 goes to Intermatic 2
Paragon terminal 3 goes to Intermatic A
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

5) Add a comment for more help

6) Take a moment and rate answer for accuracy:
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Sep 14, 2011 | Hardware & Accessories

1 Answer

Apparently, the spring under the timer dial on my 4001 timer has been broken and the timer will no longer trip the trippers. Can this be fixed? It is a nearly-new unit and I like it.


Open following link for Paragon resources:
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

Individual parts are not sold except for X2772 tripper.
Move the manual override lever back and forth and see if load turns on-off.
Watch if on-and-off trippers are moving override lever back and forth, to see if problem is a worn tripper instead of broken spring.

Replacement 4001-00 timers are sold, even though Paragon is no longer making timers except defrost timers.
http://www.mdappliance.com/RBS-4001-00.html?mv_pc=00015
Replacement timer is Intermatic T101
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Jun 29, 2011 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

I need a set of trippers for a Paragon 4001 switch timer. Need both "On " and "off" trippers. Can you find some?


Paragon 4000 series timers uses X2772 tripper
http://waterheatertimer.org/Paragon-timers-and-manuals.html

Google search x2772 tripper
Frontier Lighting shows they are out.
A couple other places show 56-60 dollars for the tripper

In November 2010, I got e-mail from Paragon saying that Paragon stopped making timers and parts for timers, except for defrost timers. 4001 is not defrost timer.

Intermatic has cross-reference link if you want to buy new timer:
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx
Cross reference shows T-101 timer matches your timer.

Aplus supply sells T101 for $60
http://www.aplussupply.com/intermatic/timer.htm
Amazon sells T101 for 43$ with free shipping over 25$
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

T101 wiring:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Jan 07, 2011 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

I get lights when I turn the switch to on but as the timer advances, it doesn't trip and turn the timer on


You posted under Intermatic T101 timer.
Add a comment if timer is different.

http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101
1) If this is new timer installation, it sounds like black wires on terminals 1 and 2 are reversed.
Other cause could be the ON-OFF trippers not positioned on timer dial

2) If this is old timer that worked before, then tripper pins could be worn down.
Buy new trippers for T101 at Grainger
http://www.grainger.com/Grainger/INTERMATIC-Timer-Tripper-2E054?Pid=search
geno_3245_74.jpg

Nov 17, 2010 | RTO Intermatic T101M Timer Mechanism Only...

1 Answer

My paragon timer4001-ov runs but will not trip on/ off trippers if this cannot be repaired what would be a good replacement for 120 volt supply


I don't see the 4001-ov in the Paragon spec sheet
http://waterheatertimer.org/pdf/Paragon-4000-24hr-7000-7day.pdf

To test the general condition of your Paragon timer, use the manual override.
If the manual override works perfectly, then you may need new tripper pins.
The Paragon 4000 series uses X2772 tripper pin.
Google search Paragon X2772 tripper turns up prices of $9 for a pair of trippers

A simple 120V replacement timer is the Intermatic T-101
For outdoor, use the T-101R 'R' for raintight

Lowes usually has the T-101 on the store shelf and they sell the T-101R online
http://www.lowes.com/pd_29405
http://www.aplussupply.com/intermatic/timer.htm
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Oct 28, 2010 | Paragon 4001-00 24-hr Timer Control 120v...

1 Answer

Intermatic T101R turns off automatically, but does not turn on automatically again when "On" pin rotates through to the set time. "On" pin is screwed on tight and I verified it is the...


If timer has been working fine up until now, you probably need a new tripper pin
http://www.grainger.com/Grainger/INTERMATIC-Timer-Tripper-2E054?Pid=search

If lever is worn out, then you need new timer.
You can but a T-101 and swap insides without changing box
The T-103 will also work because it has a 120V clock motor
The T-104 is a 240V timer and will not work
You can buy the replacement timer mechanism and swap out
http://www.grainger.com/Grainger/INTERMATIC-5225438-2E021?Pid=search
http://www.grainger.com/Grainger/INTERMATIC-24-Hour-Dial-Timer-Mechanism-2E354?Pid=search
http://www.lowes.com/T-103

When wiring new timer, put wires back the same as old timer
For T101 and T-103 wiring schematic, see following link
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Oct 28, 2010 | Intermatic & Indoor/Outdoor Rain Tight...

1 Answer

I have a 15 yr old tork 1101 pool timer. I misplaced the tripper pins the replacements P-47 dont fit. What do I do


1) Tork P47 tripper is correct tripper for 1101 timer.
Trippers are brass-colored and black-colored.
If they do not fit timer dial you might need new timer.
http://www.frontierlighting.com/find.jsp?a=1&ID=,Photo.Cells...Time.Controls,Replacement.Trippers

2) Buy new 120Volt indoor/non-weathertight Tork T1011
To identify timer for sure:
http://waterheatertimer.org/Tork-timers-and-manuals.html

3) Google search Tork 1101 shows timer cost $83

4) Intermatic cross reference shows replacement is T-101 indoor/non-weathertight
Amaxon sells T101 for 43$:
http://www.amazon.com/Intermatic-T101-Hour-Dial-Timer/dp/B00002N5FN

5) Raintight/outdoor: Aplus and Lowes sell raintight outdoor T-101R for $71
http://www.lowes.com/pd_29405-251-T101RD89_0_

http://www.aplussupply.com/intermatic/timer.htm

6) Cross over wiring.
Tork terminal X is T101 terminal A
Tork terminal 1&L are T101 terminal 1
Tork terminal 2 is T101 terminal 2

Add a comment for more free help.
Also take advantage of fixya phone service.
For a price, expert speaks with you over phone while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.

Jul 11, 2010 | TORK Digital Interval Timer Ssa100r-24

Not finding what you are looking for?
Intermatic & Indoor/Outdoor Rain Tight Timer  Logo

Related Topics:

153 people viewed this question

Ask a Question

Usually answered in minutes!

Top Intermatic Hardware & Accessories Experts

Gene Haynes

Level 3 Expert

5089 Answers

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

Steve

Level 3 Expert

3287 Answers

Are you an Intermatic Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...