1 Answer

My Whirlpool refrigerator trips the main breaker of 40 Amps

My whirlpool refrigerator model number GNF 220 trips the main breaker of 40 Amps when the defrost timer turns on.if i manually turn the timer the refrigerator starts working.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Whirlpool Master
  • 1,606 Answers

A refrig cannot pull 40 amps in defrost , unless there is a direct short in the defrost system ( timer , heater , bimetal ) . I would use an extention cord ( for test purposes only ) , and try a different plug . Sounds like the circuit breaker is weak . In defrost , the MOST you should get , is 6 amps . This will not throw a 40 amp breaker . If you have an amp meter , remove the back refrig panel behind the refrig , and connect to one of the power cord lines (just not the green ground ) , turn into defrost and check the amps . This will tell you if short is in refrig , or weak breaker .

Posted on Sep 06, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Trips power when the defrost mode turns on


There is a heating coil in the freezer that comes on to assist in defrosting. It is most likely shorted. When it comes on to defrost it trips the breaker.

Aug 19, 2015 | Jenn-Air Refrigerators

1 Answer

Whirlpool washer machine WTW5790SQO washer trips circuit breaker half way through cycle


you are pulling to many amps see if breaker is faulty first.....see if washer is in the spin and jumping around when this happens run washer with out wash in it and see if it does it something is pulling to many amps to blow breaker or could be just a bad breaker,,,, pulg something else in the wall plug that the machine is plugged in to (like a toster) and see if it trips then if so probably the breaker

Nov 11, 2011 | Whirlpool Washing Machines

2 Answers

Main breakers keeps blowing what is the reason i had the electrical company check there stuff up to the house said everything was ok no smaller breakers are blowing just the 200 main is it possible i did...


Add up all the amps from active breakers. Do they add up over 200? If not, then I suspect a bad main breaker. If they do, then you need a larger service box and or main breaker.

Sep 24, 2017 | Siemens 200 Amp Main Breaker 30 Spaces 40...

1 Answer

. I have a Kennmore Coldspot Fridge that runs for


A 15A circuit is mainly reserved for lighting.

Even some vacuum cleaners would trip a 15A circuit breaker.

The problem isn't with your refrigerator...its with the breaker installed in the breaker box.

Check your wire size and follow these rules :
12 gauge wire can have 30A c/b max
14 gauge wire can have 20A c/b max
16 gauge wire can have 15A c/b max

So, if the wires coming out of the wall socket is 12 gauge or even 14 gauge...you should be able to swap that 15A circuit breaker with a 20A circuit breaker.
This should be plenty for your refrigerator...if it "pops a 20A"...then you've got appliance problems.

If you don't feel comfortable doing that...then get a new 15A breaker...because it sounds like the other one has gotten weak.

Hope this helps

Jul 23, 2011 | Kenmore 55612 / 55614 / 5561 / 655619 Side...

1 Answer

I inherited an older model whirlpool electric dryer when I moved in...there seems to be no heat...went to get clothes out this morning and they were still damp...I wasn't given a manual - and have...


Check the breakers, by FULLY turning it off and then back on. What happens, commonly, is the heat side of the 220 breaker trips. If it keeps happening, sometimes you need a new breaker, but DO NOT increase the amp rating of the breaker. Breakers that trip from time to time, eventually start tripping EARLIER.

Jun 10, 2011 | Whirlpool Dryers

1 Answer

Need urgently Door handle for whirlpool refrigator model GNF 220X


Check with Repair.Clinic.com. They have replacement parts for a large number of appliances. Step by step replacement instructions are also available. You'll need the approximate year of manufacture, model #, and serial # of the refrigerator.

Mar 06, 2011 | Whirlpool GS6SHAXMB Side by Side...

2 Answers

New defrost timer on fridge keeps tripping circuit breaker


Hello,

The problem is the defrost timer you just replace on your refrigerator, you will need to check the ratings on the broken defrost timer to ensure it matches the ratings on the present defrost heater on your refrigerator, beside, you will need to test the continuity on your present defrost heater to see if the voltage rating is ok, because, if it can be tripping the breaker off while it kicks into defrost mode signify that the present defrost heater is not compatible with your refrigerator, it is either it is not well wired or fixed, and if it is, then, it means the defrost timer voltage rating is low compare to the former, you will need to get exact specification as the the broken one.

Take care.

Jul 10, 2010 | GE Refrigerators

1 Answer

Kenmore fridg pops circut breaker,


Sounds like a shorted heater. You advanced manully, unit runs till timer goes to defrost. Timer contacts switch, defrost heater shorted trips breaker.

Apr 04, 2010 | Frigidaire FRT21P5A Top Freezer...

2 Answers

I have a whirlpool WED5300SQ0 dryer that is on a 30 amp circuit , it trips the breaker after about 15 min ,,,it has 10 gage wiring but it is an older house , the breakers look ancient..should i replace the...


If you don't have an AMP clamp to measure the amount of AC current draw. Then I would replace the breaker with a new 30amp. If the electrical panel is a sylvania or Zinco then that is most likely the problem! Those panels use the same breaker type and are terrible at having breakers going bad and tripping premature. If it is one of those type of breakers better dig deep in your wallet as those breakers run $1.25 to $1.50 per amp !

Nov 30, 2009 | Whirlpool WED5300S Electric Dryer

1 Answer

Whirlpool model ET18MKXL trips GFCI breaker in defrost mode, heater element ohms out ok!


Make sure that your defrost timer hasn't gone bad..Check contiuity between your terminals. Hope this helps

Sep 22, 2009 | Whirlpool 18.2 cu. ft. Top Freezer...

Not finding what you are looking for?
Whirlpool ES5FHAXS Side by Side Refrigerator Logo

557 people viewed this question

Ask a Question

Usually answered in minutes!

Top Whirlpool Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4655 Answers

Charles T Nevin
Charles T Nevin

Level 3 Expert

4070 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Are you a Whirlpool Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...