Question about WYSE Winterm S30 Network Terminal

1 Answer

Reflashing wyse s30 unit

Good morning,

I have reflashed a series of Wyse S 30 units to the latest version of CE client. In doing so, I have a handful on which the upgrade will not "take." When I go to complete the upgrade, I get an error message which says the image I am trying to flash won't work with this hardware. The specific error messageis Hardware code 15070101.

These are the exact same units as those which are upgrading just fine. Any thoughts on what Hardware code 15070101 is? One thought I had was that the upgraded version of CE is already running in these units. I can't confirm, though, as I see nothing different in the system specs.

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points


    An expert that got 5 achievements.


    An expert who has written 20 answers of more than 400 characters.


    An expert who has answered 20 questions.

  • Expert
  • 112 Answers
Re: reflashing wyse s30 unit

It probably has to do with the version of CE client that is installed on the Thin Client. I have run into this problem before. The same Wyse clients can have different versions of CE installed. If the versions are the same then contact WYSE tech support to find what the error code relate to. BPCS

Posted on Dec 12, 2007

Add Your Answer

0 characters

Uploading: 0%


Complete. Click "Add" to insert your video. Add


3 Points

Related Questions:

1 Answer

Does the wyse sxo have a speaker

No, I do not believe the "S" series (S10, S30, S50 & S90) have any speakers.

Mar 01, 2013 | WYSE Winterm S30 Network Terminal

1 Answer

Wyse S30 power settings

You can check the settings in the bios (password will be "Fireport") I dont think there is anything in there that would trigger this.

Is there a screen-saver option in the control panel for the device? If so, see if it is set. If not, then try using the Wyse website to update the terminals OS to the latest. This will hopefully solve the problem. It might just be an incompatability with the older OS version.

Jun 22, 2009 | WYSE Winterm S30 Network Terminal

1 Answer

How can i reset S30 wyse box

Try a G-key reset.

Failing that use WSI and an S30 image from the wyse Website.

WDM also has the option to to re-image the client.

You may also be able to get into the control panel of the terminal, and download an FTP image and set the terminal to upgrade from the image when uploaded to your ftp site. From the control panel, you can initate the upgrade manually

Mar 24, 2009 | WYSE Winterm S30 Thin Client - Thin Client...

1 Answer

Issues with Keys on Wyse and Citrix

Do you know what image version you are using on this terminal? It might be best to download the latest firmware for the device, and upgrade.

You can download WYSE imaging tools, and images from their website for free.

You can also download ICA client upgrades for your unit from there too. This will hopefully solve your problem.

Nov 26, 2008 | WYSE S90 THIN CLIENT KB/MSE XPE...

1 Answer

Howto add a network printer on Wyse winterm S30 terminal?

The S30 terminal has the CE 5.0 operating system loaded as default. So you are limited by the operating system and not the hardware when it comes to network printing.

Here is a extract of the release notes for Windows CE 5.0:

"In Windows CE, TCP/IP supports network printing through the Server Message Block (SMB) protocol. It does not provide the Windows Line Printer Remote (LPR) Spooler. However, independent software vendors (ISVs) and original equipment manufacturers (OEMs) can add this support."

In short, you need a 3rd party software program or a (SMB) printer server setup to setup network printing on the S30 terminal..

Wyse also have add-on software to help, if you have CE 5.0 loaded then try the "Thinprint" add-on supplied as a free download by them.
Download Link:

I haven't tried this, so let me know if it works.

May 02, 2008 | WYSE Winterm S30 Network Terminal

1 Answer

Wyse 1200LE - error - out of frequency

The display settings are not valid with the monitor. Either you are using a new monitor or you have changed the settings. If you are using a new monitor, swap with the old monitor and configure the appropriate refresh rate for the new monitor.

If you have changed the settings you may need to either reset all default settings, or setup a parallel unit and use the same key strokes to change the display settings on the problem unit.


Apr 02, 2008 | WYSE Winterm S30 Network Terminal

2 Answers

Uncontrolled scrolling in excel

You System has been attacked by a virus or bug try scanning your PC in safe mode with the latest dat file of MC afee or trend micro. I have faced a similar problem recently and and have got rid of it this way only. Good Luck

Oct 08, 2007 | WYSE Winterm S30 Network Terminal

3 Answers

Hardware reset

Double-clicking the System icon in the Control Panel opens the System Info dialog box.You can use this dialog box to allocate thin client memory and reset the thin client to factory defaults.

The General tab contains a check box that allows you to reset the thin client to factory defaults (the check box is active for administrators only).

You can reset the thin client to factory default settings by selecting the *Reset the terminal to factory-default property settings* check box (the System Settings Change message displays and you can confirm and follow the instructions provided to reset the thin client).

Mar 01, 2007 | WYSE Winterm S30 Network Terminal

Not finding what you are looking for?
WYSE Winterm S30 Network Terminal Logo

810 people viewed this question

Ask a Question

Usually answered in minutes!

Top WYSE Network Terminals Experts

Rick Johnson
Rick Johnson

Level 2 Expert

84 Answers

Brad Brown

Level 3 Expert

13369 Answers

Mike Neath
Mike Neath

Level 3 Expert

315 Answers

Are you a WYSE Network Terminal Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides