Hi,
I read that "Frost free refigerator models with a top mount freezer utilize a drain to take the water melted off the coils to the evaporator pan. This pan collects the water in the bottom of the unit sometimes using the heat of the compressor to increase the evaporation rate. If this drain becomes clogged with ice or debris it will back-up and eventually over flow. This overflow usually collects in the bottom of the fresh food compartment below but can also leak onto the floor."
...and that the solution to this problem is to: "locate the drain and inspect it for blockage. Often the drain tube is simply frozen over and requires the application of warm water to free the clog. However, it could be solid debris that must be removed from the drain."
The online user manual and guide at FixYa states that: "The water generated during the defrosting flows down to the drip tray located at the back part of the refrigerator and its evaporated automatically."
Any idea of how I can access the drain to thaw it out?



Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 2,976 Answers

Some units don't have a drain tube. The water flows down the back of the fridge into the bottom and it just makes a mess. It has been a problem ever since they started going "Energy efficient". The drain was a hole and they had to close the holes. If you're lucky enough to have the drain, it will be located inside the back wall of your freezer. The inside walls must be removed. The drain will be in the drip pan, below the freezing coils (fins) in the back of the freezer.

Posted on Sep 05, 2009

Testimonial: "Thanks!"

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Water under vegtable bin every day runs out on to kitchen floor


Hi


Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.
Your drain tube may be clogged up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help.
Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the lower back of the freezer.


Please get back to us if you have further query else please accept the suggestion.
Thank you for contacting fixya.com








Aug 05, 2011 | Frigidaire 16.5 Cu. Ft. Top-Mount...

1 Answer

The refigerator links water in the inside


The evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.


Your drain tube may be stopped up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help.
Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the inside of the freezer at the bottom of the rear cover.

Oct 28, 2010 | Frigidaire FRT15B3A Top Freezer...

1 Answer

Water is dripping from the top into the fridge in the back is frozen up and condensation is forming at the top of the fridge ceiling...dripping down.


The evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.


Your drain tube may be stopped up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help.
Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the back of the freezer.

Aug 10, 2010 | GE 18.2 Cu. Ft. Frost-Free Top-Mount...

1 Answer

HOT POINT FRIDGE - FREEZER DRIPS WATER


The evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.

Your drain tube may be stopped up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help. Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the back of the freezer.

Jul 12, 2010 | Hotpoint HTS16HBR Top Freezer Refrigerator

1 Answer

Water in refrigerator and excessive condensation on bottles


Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.


Your drain tube may be stopped up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help.
Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the lower back of the freezer.

May 21, 2010 | Maytag 21.7 Cu. Ft. Top-Mount Refrigerator...

1 Answer

Leaking water in refigerator. Inside Ceiling of frig.


Normal 0 MicrosoftInternetExplorer4 st1\:*{behavior:url(#ieooui) } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.


Your drain tube may be stopped up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help.
Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the lower back of the freezer. If this repeatedly happens with yours, you may can prevent it by taking a bare copper wire and wrap it around a fin near the heater and put the other end a few inches down the drain. The heat convection may prevent it from freezing.

Jan 27, 2010 | GE J Series 18.2 cu. ft. Top Freezer...

1 Answer

WATER LEAKING FROM FREEZER VENTING INTO FRIDGE


Normal 0 MicrosoftInternetExplorer4 st1\:*{behavior:url(#ieooui) } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.


Your drain tube may be stopped up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help.
Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the lower back of the freezer.

Jan 12, 2010 | Refrigerators

1 Answer

Frigidaire upright freezer Model # FFU14FC4AW0 frost free has water that accumulates under it. It's like it is leaking water on the floor. Not alot, but it has to wiped up and is leaving water stains on...


Normal 0 MicrosoftInternetExplorer4 st1\:*{behavior:url(#ieooui) } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.


Your drain tube may be stopped up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help.
Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the lower back of the freezer.

Nov 30, 2009 | Washing Machines

1 Answer

Model TBX21KLK water pooling UNDER vegetable bins


Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.


Your drain tube may be stopped up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help.
Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the lower back of the freezer.

Sep 21, 2009 | Refrigerators

1 Answer

Water in my Fridge


Your evaporator coils frost up in normal use and every eight hours or so the entire unit shuts down and the defrost heater comes on to melt the frost. This cycle last about 20 minutes. The melted frost drips into a drain pan and through a drain tube to the drain tray under the freezer/refrigerator where it's evaporated by the condenser fan.


Your drain tube may be stopped up with ice at the upper end because it drains too slow because it's stopped up at the lower end in the evaporator pan under the unit at the floor. It can get dust and mold in it. Once you get the ice out at the top a little pressure with a turkey baster will usually clear it out. Flushing it out with hot water and clorox may help.
Make sure it drains quick enough to prevent refreezing. . The drain should be located below the evaporator coils on the lower back of the freezer.

Sep 15, 2009 | Frost Inglis 17.6 Cu. Ft. -Free Top-Mount...

Not finding what you are looking for?
LG LRTP1231W Top Freezer Refrigerator Logo

846 people viewed this question

Ask a Question

Usually answered in minutes!

Top LG Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4654 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

christian nielsen

Level 3 Expert

358 Answers

Are you a LG Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...