Question about Hobart 24 in. LXIH-3 Built-in Dishwasher

3 Answers

LX30H Hobart torsion bar adjustment

I have a hobart LX30H when you open the door if you dont hang on it just slams right down. Is there a way to adjust the torsion bar on this machine, I called Hobart and was told no that i needed to buy a torsion bar ,torsion bar assymbly,and 2 o ring any help would be nice thanks

Posted by on

3 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points


    An expert that got 10 achievements.


    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 640 Answers
Re: LX30H Hobart torsion bar adjustment

Im a service tech for hobart,there are no adjustments,the torsion bar is broken.the parts arent expensive but installing them are tricky.

Posted on Dec 16, 2007

Re: LX30H Hobart torsion bar adjustment - Hobart 24 in. LXIH-3 Built-in Dishwasher Dishwashers


Posted on Aug 09, 2008

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer
Re: LX30H Hobart torsion bar adjustment

Wind them up

Posted on Jan 03, 2008

Add Your Answer

0 characters

Uploading: 0%


Complete. Click "Add" to insert your video. Add


3 Points

Related Questions:

1 Answer

Hobart lx30h leaking from bottom

This is a testing for the post on this web site, not a solution.

Mar 27, 2014 | Hobart Lx30h Commercial Dishwasher

1 Answer

LX30H THROWS A CODE EO after running awhile. I hit the high reset button under the flaps on the front for both the boost and reg elements . It will work for a couple cycles and then does the same thing....

Machine won't fill or won't fill high enough. site water pressure meets minimum flow pressures. (LX18, LX30 display shows working.
"E0," "E2," "E3," or "E4". LX40 display shows "DR1 PRBLM," "FILL1 PRBLM," FILL2 PRBLM," or "FILL3 PRBLM". Machine will not run.)

1. Low water pressure - check for clogged hose strainer; check that

2. Make sure probes are clean

3. No water pressure - main water supply valves may not be

4. Drain valve open - turn machine OFF to drain machine, then
ON. Repeat twice (this assists in clearing any drain valve
obstructions). Wait for machine to reach READY mode and
press WASH. Slowly open door several seconds later and note
water level. Close door; 30 seconds later, open door slowly and
check that water level is the same as it was. If not, repeat the
OFF-ON procedure. If problem persists, call your local Hobart
Service Office.

5. Delime machine.

Dec 10, 2013 | Hobart Lx30h Commercial Dishwasher

1 Answer

Hobart lx30h rinse additive is running all the

The main cause is the "anti flood" device at the bottom of the washer that detects a water leak "hose leak" etc. This device made up of a polystireen float and micro switch is a safety device and when activated puts the washer in pump out mode only. You need to look at the base of the washer and see if water leak has caused this. Rectify the cause "normaly hose or clamp" and this should clear the

Mar 21, 2010 | Hobart 29 in. AM15-1 Free-Standing...

1 Answer

Hobart dishwasher model LX30H displays -5 on

by the way you're describing the problem, i would have to say there is something wrong with your control board. part#473173 can be bought @ any hobart office in your area. dont forget to vote

Feb 07, 2010 | Hobart 24 in. LXIH-3 Built-in Dishwasher

1 Answer


the p2 err. is on open or shorted rinse thermistor which is located on the back of the mach next to the vac. brkr. as for draining ck the drain valve for debris, and the end of the drain hose where it connects to the building drain

Dec 25, 2009 | Hobart 24 in. LXIH-3 Built-in Dishwasher

1 Answer

Lx30h hobart dw. booster will not turn on. element good,hi-limit is good, changed temp probe, still no power to contactor

The booster heat control circuit is controlled by the relay board. Visually check for loose or burnt relay contacts...
You will see the booster LED light when it calls for heat. Some newer machines have a second high limit on the right hand side of the booster tank.
It may be your control board is configured for low temp with no booster. When you power up, the display should say LX30H. If not
Pull open the upper drawer, place a magnet over the door interlock switch.

CAUTION, 220 volt power is present. be carefull what you touch.

on control board, short J5-1 and J5-2, then power up. You are in factory setup. press select on the control board to see each option on the front panel., press up arrow on control board to step up through options for each step. when done, press the off button on front panel. remove short and start up normally. With the magnet in place, AND THE DOOR CLOSED, run the machine and observe the relay board status lights.
If you want to adjust the temp set points, with the machine off, press and hold the hidden key behind the front panel logo, and press select on the control board.. Or on power up, hold the wask key..Same to adjust options as above. Press off to exit.

Jul 04, 2009 | Hobart 24 in. LXIC-5 Built-in Dishwasher

1 Answer

Hobart dishwasher model LX30H; displays wrench and E4.

Water is not to top sensor in alotted time.
Top sensor is in right rear corner, and is the upper of the two. Check the connector to the probe on the outside at the back. (sometimes gets wet fro vacuum breaker leaking when dirty or low flow pressure. Machine needs 20 psi flow rate

Dec 11, 2008 | Hobart 24 in. LXIH-3 Built-in Dishwasher

Not finding what you are looking for?
Hobart 24 in. LXIH-3 Built-in Dishwasher Logo

685 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hobart Dishwashers Experts


Level 1 Expert

36 Answers


Level 3 Expert

57192 Answers


Level 2 Expert

55 Answers

Are you a Hobart Dishwasher Expert? Answer questions, earn points and help others