There are Five Main reasons that this will happen
1 - A bad run capacitor (silver or metal capacitor)
It’s either shorted, grounded or open.
If it’s shorted a lot of times it will bulge out, (sometimes slightly)
2 - A bad start kit ( plastic capacitor and Relay connected to it )
The capacitor is either shorted or open
The relay either has an open coil between terminals #1 and #5
Or the relay is stuck.
Any time you change the capacitor or relay you should change
the other, especially if they are over a year old.
3 - A loose, burnt or disconnected wire
4 - Wired wrong
5 Compressor is locked up
After a lengthy period of inactivity, we came to use the dehumidifier and noticed that the LED...
(More)
After a lengthy period of inactivity, we came to use the dehumidifier and noticed that the LED screen was no longer lit. As a result we cannot see the settings.
I have been emptying the tank few times a day, because I had no convenient drain in basement. Now, I...
(More)
I have been emptying the tank few times a day, because I had no convenient drain in basement. Now, I have a drain and can connect garden hose to the back of machine...but I have misplaced my remote and manual. What must I do to make it work? Thx.
Model DDR6588EE - called Danby and they will not tell me what part I need or how I can order it due...
(More)
Model DDR6588EE - called Danby and they will not tell me what part I need or how I can order it due to liability associated with electrical work needed. Authorized service people will charge at least $120 (all-in) to diagnose what sensor it is, order sensor and repair it...bottom line is that i think i need to get a new one (NOT A DANBY)... if anyone else has any ideas on a solution, please let me know...
My unit is collecting moisture VERY WELL! BUT it blows warm air only which makes it very hot in our...
(More)
My unit is collecting moisture VERY WELL! BUT it blows warm air only which makes it very hot in our apartment - anyway I can get it to stop blowing warm air from the top??