Question about Refrigerators

Open Question

Orient Inverter AC throwing F1 error

This Orient Ultron Series model OS-19K7 WD IN-HC has been throwing F1 error code since its installation 3 years ago. Sometimes it gives this error after 10 minutes of run time while at other times it would operate for days and then give this error. The refrigerant pressure is tested to be accurate. When it displays F1, the indoor fan keeps running but the compressor and condenser fan stops. I can't find any troubleshooting documentation online. All advice is appreciated.

Posted by on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE:

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad
louislevel_2
  • 374 Answers

SOURCE: Samsung Ac compressor stops after 20 minutes and fan keep running

eventually,cycling process is doing done if the thermostat sense the configure temperayure set up it will trigger to stop your compressor motor as well as the blower fan,blower fan independenly to you compressor.if your thingking that your compressor is tripping off,check your operating current on one line using clamp ammeter and compare to the rated current that tag on
motor compressor body,if the current flow is higher than the rated current specified on compressor motor,well problem occured it will trip your compressor,because overload protector is becoming your thermostat.but if you got same current result it was cycling process.If tripping off maybe air is present in your system call qualified ac tech, to purge out air in system.

Posted on Mar 16, 2009

Ad
  • 1 Answer

SOURCE: DeLonghi Planus quick connect split heat pump.

I was told by a delonghi technician that it does this to defrost the unit.
Hope this helps.

Posted on Apr 22, 2009

Sea Breeze
  • 4655 Answers

SOURCE: My refrigerator (RB1855) runs excessively long.

There are about four different versions of your model. If you like I will send you the manual and we will work together as this refrigerator is very complex. Let me know, Thanks, Sea Breeze

Posted on Jul 11, 2009

  • 21 Answers

SOURCE: model#asu9cq error code

need model and make, and serial if you have it, its an error code, but without make, cant tell u!

Posted on Aug 06, 2009

  • 603 Answers

SOURCE: Compressor appears to kick in, runs for short time

It sounds like your unit may have a bad run capacitor or start capacitor and relay. Low voltage will also cause this problem. First you need to make sure that you have the full rated voltages at the unit, if you do, then, have the run and start capacitors checked out and the start relay.

Posted on Jun 01, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Did new installation of ACI24H1P INVERTER MIDWALL NOW it shows F1 error


I'm not finding that model but yes, unlikely, if two separate outdoor units that both are damaged. Either there simply isn't one and the configuration is not right or the connection is loose or sensor is not secure.

If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79

Aug 26, 2017 | Inverter Heating & Cooling

1 Answer

Orient ultron dc inverter shows F7 And no cooling at all throws hot air How to fix it?


Its low voltage problem
When voltage drops lower than 150
F-7 comes on my pel inverter ac

Jun 24, 2017 | Inverter Heating & Cooling

1 Answer

Fix f5 e 1


F1 - E0 EEPROM communication error 1. Disconnect power for at least 30 seconds.
2. Re-apply power and observe for at least one minute.
3. If code re-appears, replace control board (also called ERC or clock).

Note: Applies to all F1-E... codes except F1-E3. F1 - E1 EEPROM checksum error F1 - E2 UL A/D error(s) F1 - E4 Model ID error F1 - E5 Calibration shifted F1 - E6 Latch signal mismatch error F1 - E9 Stack overflow F1 - E3 Wiring harness cavity size does not match previously stored value The "Cavity Size Select" jumpers in the wiring harness indicate a cavity size different from that which the control was previously configured for. Check the jumpers in the harness to make sure they agree with the actual oven size.

Jun 05, 2015 | KitchenAid Architect II Superba EQ Series...

2 Answers

My orient split a.c shows Ec error in digital display


sir plz answer me my ac orien 1 ton showing EC error on display what is this i can't understand what is this plz reply

Jul 12, 2014 | Heating & Cooling

1 Answer

Gree air conditioner error codes HC


I have also use GRE ac inverter but today my ac on running sundunly show (HC )Main screen
Plz information this system
HC maens what's problem

Aug 19, 2013 | Heating & Cooling

1 Answer

My oven when turned on goes to F1 and the heat is like broil...only the top burner comes on????


Hello,Please use the chart to determine which stove you have. You will have to look at the model number. The first 3 numbers will be the series on the chart. In most cases an F1 error would require replacement of the electronic control. This part is commonly refered to as an EOC or ERC. However this type of repair is usually reserved for repair specialists.

KENMORE Range/Stove/Oven Fault Codes – 362 Series (General Electric)
F1 = Stuck Touch Pad Key - Replace Electronic Range Control (ERC).

KENMORE - 911 Series (General Electric/Roper)
F0-F1-FF = Failed transistor in Electronic Range Control (ERC).

KENMORE Range/Stove/Oven Fault Codes- 665 Series (Whirlpool)
F1-E0 EPROM Error - Electronic Range Control (ERC).
F1-E1 EPROM Error - Electronic Range Control (ERC).
F1-E2 U/L ERC Errors - Electronic Range Control (ERC).
F1-E3 Fuel Type Fail

Kill power 30 seconds-Cancel-Start/Enter-5 seconds-Should see “E” for electric-
“9” for gas-If code changes again-replace Electronic Range Control (ERC).

KENMORE - 790 Series Electronic Oven Control (Frigidaire)
F1 = Shorted Touch Pad = Electronic Range Control (EOC) Internal check sum error.
Runaway Temp = Replace Electronic Oven Control (EOC).

Kill power 30 seconds - if error returns - replace Electronic Oven Control (EOC).

Thanks

May 28, 2010 | Kenmore 40494 / 40495 / 40499 Electric...

1 Answer

66993 pizza oven microwave oven combo pizza oven not heating error code f1 microwave part works


Hello, please use the chart to determine which stove you have. You will have to look at the model number. The first 3 numbers will be the series on the chart. In most cases an F1 error would require replacement of the electronic control. This part is commonly refered to as an EOC or ERC. However this type of repair is usually reserved for repair specialists.

KENMORE Range/Stove/Oven Fault Codes – 362 Series (General Electric)
F1 = Stuck Touch Pad Key - Replace Electronic Range Control (ERC).

KENMORE - 911 Series (General Electric/Roper)
F0-F1-FF = Failed transistor in Electronic Range Control (ERC).

KENMORE Range/Stove/Oven Fault Codes- 665 Series (Whirlpool)
F1-E0 EPROM Error - Electronic Range Control (ERC).
F1-E1 EPROM Error - Electronic Range Control (ERC).
F1-E2 U/L ERC Errors - Electronic Range Control (ERC).
F1-E3 Fuel Type Fail

Kill power 30 seconds-Cancel-Start/Enter-5 seconds-Should see “E” for electric-
“9” for gas-If code changes again-replace Electronic Range Control (ERC).

KENMORE - 790 Series Electronic Oven Control (Frigidaire)
F1 = Shorted Touch Pad = Electronic Range Control (EOC) Internal check sum error.
Runaway Temp = Replace Electronic Oven Control (EOC).

Kill power 30 seconds - if error returns - replace Electronic Oven Control (EOC).

Thanks

Jul 20, 2009 | Kenmore 63662 / 63664 / 63669 Microwave...

1 Answer

My kenmore oven is beeping and will not stop. the display shows F-1.


Please use the chart to determine which stove you have. You will have to look at the model number. The first 3 numbers will be the series on the chart. In most cases an F1 error would require replacment of the electronic control. This part is commonly refered to as an EOC or ERC. However this type of repair is usually reserved for repair specialists.

KENMORE Range/Stove/Oven Fault Codes – 362 Series (General Electric)
F1 = Stuck Touch Pad Key - Replace Electronic Range Control (ERC).

KENMORE - 911 Series (General Electric/Roper)
F0-F1-FF = Failed transistor in Electronic Range Control (ERC).

KENMORE Range/Stove/Oven Fault Codes- 665 Series (Whirlpool)
F1-E0 EPROM Error - Electronic Range Control (ERC).
F1-E1 EPROM Error - Electronic Range Control (ERC).
F1-E2 U/L ERC Errors - Electronic Range Control (ERC).
F1-E3 Fuel Type Fail

Kill power 30 seconds-Cancel-Start/Enter-5 seconds-Should see “E” for electric-
“9” for gas-If code changes again-replace Electronic Range Control (ERC).

KENMORE - 790 Series Electronic Oven Control (Frigidaire)
F1 = Shorted Touch Pad = Electronic Range Control (EOC) Internal checksum error.
Runaway Temp = Replace Electronic Oven Control (EOC).

Kill power 30 seconds - if error returns - replace Electronic Oven Control (EOC).

Dec 16, 2008 | Ovens

4 Answers

My kenmore electronic stove is having a beep with code F1 on the


Please use the chart to determine which stove you have. You will have to look at the model number. The first 3 numbers will be the series on the chart. In most cases an F1 error would require replacment of the electronic control. This part is commonly refered to as an EOC or ERC. However this type of repair is usually reserved for repair specialists.

KENMORE Range/Stove/Oven Fault Codes – 362 Series (General Electric)
F1 = Stuck Touch Pad Key - Replace Electronic Range Control (ERC).

KENMORE - 911 Series (General Electric/Roper)
F0-F1-FF = Failed transistor in Electronic Range Control (ERC).

KENMORE Range/Stove/Oven Fault Codes- 665 Series (Whirlpool)
F1-E0 EPROM Error - Electronic Range Control (ERC).
F1-E1 EPROM Error - Electronic Range Control (ERC).
F1-E2 U/L ERC Errors - Electronic Range Control (ERC).
F1-E3 Fuel Type Fail

Kill power 30 seconds-Cancel-Start/Enter-5 seconds-Should see “E” for electric-
“9” for gas-If code changes again-replace Electronic Range Control (ERC).

KENMORE - 790 Series Electronic Oven Control (Frigidaire)
F1 = Shorted Touch Pad = Electronic Range Control (EOC) Internal checksum error.
Runaway Temp = Replace Electronic Oven Control (EOC).

Kill power 30 seconds - if error returns - replace Electronic Oven Control (EOC).

Dec 15, 2008 | Kenmore 40494 / 40495 / 40499 Electric...

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

41 people viewed this question

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

Marvin
Marvin

Level 3 Expert

84619 Answers

Brad Brown

Level 3 Expert

18060 Answers

Gil Shultz

Level 3 Expert

3388 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides