Dehumidifier - hot compressor / coils not cold

Cleaned coils. Fan does work. Coils do not get cold.
Checked the thermostat, overflow - all ok using volt/ohm meter.
Any suggestions or additional checks I might do to isolate problem would be greatly appreciated.
Thanks!

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Guru:

    An expert who has written 7 tips or uploaded 3 video tips

  • Master
  • 587 Answers

If the compressor's running and it's getting hot and the coil isn't getting cold, then you are probably low on refrigerant or your txv or metering device isn't working.

Posted on Aug 25, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a 2 yr old dehumidifier and it runs, it just won't pull out the moisture out of the air.


There are 5 basic, but solvable reasons for what you described. Please pay particular attention to numbers 1 & 2.

1. The humidity extraction level is set to HIGH. Lower it to 32-35%. If you have an analog unit
(No LED screen), set the humidity extraction knob on Maximum.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

I hope this helped you and thanks for choosing FixYa

Sep 13, 2011 | Kenmore 938060 Humidifier

1 Answer

DEHUMIDIFIER IS RUNNING BUT NOT COLLECTING WATER


There are 5 basic, but solvable reasons for what you described. Please pay particular attention to numbers 1 & 2.

1. The humidity extraction level is set to HIGH. Lower it to 32-35%.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder
level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

Hope this helps you to troubleshoot & solve the problem. Thanks for choosing FixYa.

Jul 28, 2011 | Whirlpool AD25BBR 25 Pint Per Day...

1 Answer

Our Kenmore 50pt dehumidifer is less than 2 years old, only used for 1 summer, tried to use it last week, it starts/runs but does not withdraw any water, please help. Thanks kindly


There are 5 basic, yet solvable reason for what you described. Please pay particular attention to numbers 1 & 2.

1. The humidity extraction level is set to HIGH. Lower it to 32-35%. If you unit is manual control,
turn the control knob to Maximum.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter. Filter should be cleaned once every 2 weeks.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder
level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

I hope this helped you to troubleshoot and solve the problem. Please let me know. Thanks.

Jun 29, 2011 | Humidifiers

1 Answer

Whirlpool accudry dehumidifier doesnt work, the fan runs, but i think theres something wrong with the compressor, it clicks (on and off it seems) every bout 5 seconds. what could the problem be?






Hi,


There are many reasons why a dehumidifier will not work or collect water.


Here is a tip that I wrote to help people to figure out what is going wrong with their dehumidifier

Dehumidifier is running but no water is in bucket

heatman101


=-=-=-=-=-=-=-=-=-=-=-=-=-=-

Sep 14, 2010 | Whirlpool AD25BBR 25 Pint Per Day...

1 Answer

Dehumidifier not collecting water


do the lines from the compressor to the evaporator freeze up or ice up anywhere,if so it could be low on refrigerant,also check the start capacitor in the compressor power circuit,if its bad the compressor won't run

Apr 04, 2010 | Whirlpool AD25BBR 25 Pint Per Day...

1 Answer

Does not dehumidify


Hello. I am here to help. Let me begin by saying that a dehumidifier only needs to be operated if the humidity in your home is too high. If the humidity is low, the humidifier will have to work really hard to try and remove water from it.

Here is an overview of how the dehumidifier is supposed to work:

When the unit runs, the circulating fan and compressor also run. The fan continually draws room air over the evaporator coils, which are cold, and then over the condenser coils, which are warm. Because the evaporator coils are cold, the moisture in the room collects on them--just as the outside of a glass of icy liquid "sweats" on a warm, humid day. When the moisture on the coils increases, it drips off of the coils into the collection container.

The air then flows over the warm condenser coils and out into the room. This process removes water from the air and, because of the heat from the fan motor and compressor motor, the exiting air is somewhat warmer, as well as dryer.

May 20, 2009 | Whirlpool AD40U Humidifier

1 Answer

Motor runs, but does not collect any water in yank


Make sure any air filters are clean. Check to be sure the evaporator and condenser coils are very clean. Also could the humidity level in your home just be very low right now and just no moisture to remove? If all of this fails it could be a compressor problem or a refrigerant level issue. If this is the case determine if it is worth the expense to repair.
Good luck

Mar 28, 2009 | Whirlpool AD25BBR 25 Pint Per Day...

11 Answers

The humidifer on the Sunpentown SH-1500 heater


what country are you in... winter time is low humidity to begin with.

Robert

Jan 06, 2009 | Sunpentown 1500W Heater Fan Humidifier...

Not finding what you are looking for?
Whirlpool AD50USR 50 Pint Per Day Ultra Low Temp Basement Dehumidifier w/ AccuDry Sensing System &EN... Humidifier Logo

1,495 people viewed this question

Ask a Question

Usually answered in minutes!

Top Whirlpool Humidifiers Experts

Mack Baxter

Level 3 Expert

383 Answers

Dennis

Level 2 Expert

231 Answers

yadayada
yadayada

Level 3 Expert

76630 Answers

Are you a Whirlpool Humidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...