I got a dryer with no cord... I bought a cord and wired it in and nothing happens.

I matched the red, black, white and bare. But whats with the green floating around in the dryer not attached to anything. Im assuming this is the problem and why are there two reds?

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points


    An expert that got 10 achievements.


    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 447 Answers
Re: I got a dryer with no cord... I bought a cord and...

The green is the ground put it on the bare wire. not sure why there are 2 red unless someone replaced the terminal block and had a red replacement.

Posted on Nov 23, 2007

Add Your Answer

0 characters

Uploading: 0%


Complete. Click "Add" to insert your video. Add


3 Points

Related Questions:

1 Answer

4 prong cords

Either way, plug or dryer cord the white wire goes with the green wire, they are pretty much the same. On the dryer at the block where you are connecting the cord, look just above it and you'll see wires coming into it, the red and black are on the outside, I'm not sure which color on which side but the white and green go in the middle on top one another and the red and black match respectively.

May 17, 2012 | GE DBXR463EBWW Electric Dryer

1 Answer

Wiring conia ccd4501

There could be two situations for you. For the wall outlet, you may have a four prong plug or a three prong plug. For a three prong plug the outlet has three prongs and the terminals inside match up with these prongs. The two slanted prongs on the top are the hot terminals and the red and black wires get connected to these (order doesn't matter but keep the wires matched up with the terminals on the same sides). The white wire is connected to the "L" shaped prong, the third lower prong. The bare copper wire is just bent out of the way. At the dryer for the three prong there will be three terminals 2 hot and one neutral. Usually, your dryer cord will have the neutral as the middle wire, but pay attention if your cord wires are color coded (where white will be your neutral wire). At the dryer there is a terminal which is connected to the frame of the dryer by a piece of metal. This is your neutral, connect your neutral wire from your cord up to this. The other two wires get connected to the other two terminals (order doesn't matter but keep the wires matched up with the terminals on the same sides). For the four prong its very similar but there is a small change, that bare copper wire is now used. The terminals on the wall outlet will line up with the prongs. The two vertical terminals on the left and right are your red and black wires. The "L" shaped prong is your white wire. Now the fourth prong, the one shaped like a semi circle is the terminal you connect that bare copper wire up to that is your ground. At the dryer for the cord (If its a four prong cord your wires should definitely be color coded). The terminal that had a connection to the dryer frame now will no longer have one. The terminal thats connected to the frame you connect the green wire to. The terminal that was connected to the "green wire terminal' is now the neutral terminal and your white wire gets connected to it. The other two terminals are where your connect your last two wires.

May 10, 2010 | Dryers

3 Answers

I have a 3 wire dryer and need to convertto a 4

The following link explains how to correctly install a 220VAC appliance cord:

Match the corresponding colors at the terminal block, making sure the Neutral (White) and Ground (Green or Bare Copper) wires are NOT terminated together.

If you have any questions, please post back and let me know. I hope this helps you.

Feb 03, 2010 | Kenmore 62602 Electric Dryer

1 Answer

Dryer did not come with electrical cord so I bought one.

The following link explains how to correctly install a power cord on your dryer:

The main difference between the 3-wire and 4-wire configuraiton is how the Neutral (WHITE) wire and Ground (GREEN or BARE COPPER) wire are terminated on the terminal block in the back of the dryer:

- In a 3-wire configuration, these two wires are connected together via a ground strap at the terminal block.

Terminate the wires at the terminal block by matching the corresponding colors:

WHITE to WHITE (Neutral) 0VAC - Neutral should also have a ground strap attached that grounds it to the equipment cabinet or ground lug.

NOTE: Newer homes built after the year 2000 REQUIRE a 4-wire configuration to be in complaince with the National Electric Code. In addition, some newer appliances may not work correctly without a 4-wire power cord.

If you have any questions, please let me know. I hope this helps you

Dec 23, 2009 | Kenmore 62602 Electric Dryer

1 Answer

Need to reconnect dryer power cord. Black to

In most cases your black and red wires will be the hot wires and the bare(green) or white will be your ground and grounding wires.

Oct 15, 2009 | Maytag Atlantis MDE7400AY Electric Dryer

2 Answers

New house requires 4 prong plug for dryer...mine has 3...bought new cord...How to wire it?

The old three prong, the vertical prong is neutral (white wire), the two slanted are 220 volts. The new plug, the extra prong is ground (bare wire). Shut off the outlet at the breaker panel, and remove the outlet to examine the wiring to it. It should be as above--the 220 volt wires are red and black or black and black. The ground wire is bare or green insulated. Inside the dryer case, tie the green and white wires to the dryer case, and tie the two outside wires where they went with the old cord. Check with an electrician if you are unsure about this.

Jul 16, 2009 | Dryers

2 Answers

Replace a 3 wire power cord with a 4 wire power cord.

red on one end, black on the other, white in the middle, green to cabinet ground.

Jun 12, 2009 | Dryers

1 Answer

I needs help with installing eltetric cord in the back of dryer


Mar 20, 2009 | Kenmore 63012 Electric Dryer

1 Answer

Hooking up the four prong cord to the dryer

this is the rule of thumb,white always goes on the middle terminal ,the 2 outside terminal wires it does not matter which side they are on,if you can see the red and black wire on the terminal block then match them up,the green wire gets mounted to the cabinet,you should already have a green wire to the cabinet so remove the screw and put both wires there and your done,let me know how you do-mike

Oct 15, 2008 | Frigidaire FEQ332E Electric Dryer

1 Answer

Used maytag electric dryer installation question

First off, you should be wiring your power cord directly to the terminal block inside the dryer. If someone just cut off the cord that is terminated inside the dryer, and you are attempting to splice the new cord onto the old one.. you are making a mistake.. take the new cord and bond it directly to the terminal block inside the dryer. If you have a new 4-wire power cord, you are probably dealing with a red/black/white and green wire. ( assuming it is a four prong plug).. The black and red wires are the power lines themselves and should mate with the red and black wires inside the dryer. The green ( is frame ground) and is normally bonded to a stud near the terminal block or the dryer frame. The white is the neutral line and is normally tied to the terminal in the middle and between the red and black tie points.. In line splices should not be done on this appliance.. Hope this helps..

Sep 06, 2008 | Dryers

Not finding what you are looking for?
Roper REX3614KW Electric Dryer Logo

Related Topics:

48 people viewed this question

Ask a Question

Usually answered in minutes!

Top Roper Dryers Experts

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Tim Whalen

Level 3 Expert

3056 Answers

Richard Roth
Richard Roth

Level 3 Expert

9472 Answers

Are you a Roper Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides