Question about Heating & Cooling

2 Answers

My KOLIN window type remote control AIRCON is building up ICE

WHEN I NOTICED THAT MY AIRCON WAS BUILDING UP SOME ICE, I HAD IT CLEANED AS IT IS ALREADY DUE, BY AN AUTHORIZED TECHNICIAN HOPING THAT THE PROBLEM WOULD BE SOLVED. HOWEVER, I FOUND OUT DAYS LATER, THAT ICE STILL BUILDS UP . THE AIRCON STILL COOLS UP MY ROOM,BUT NOT AS MUCH AS BEFORE. I WOULD KNOW THAT ICE IS BUILDING UP WHEN I COULD NOT FEEL THE BLOWER AS I GO NEAR THE AIRCON. I WOULD THEN PUT THE AIRCON TO FAN SETTING THUS MAKING THE TEMPERATURE RISE (HOT) CAUSING THE ICE TO MELT AND DROP. I WOULD THEN HEAR SOME CRANKING NOISE AS THE ICE POUNDS AGAINST THE SUCTIONING BLADE OF THE FAN MOTOR. THENAFTER,I WILL AGAIN PLACE THE SETTING TO COOL. THIS HAS BEEN GOING ON FOR ABOUT A MONTH AND FOR THE REASON THAT MY AIRCON STILL COOLS UP MY ROOM ,I HAVE NOT CONTACTED ANY AIRCON MECHANIC YET. PLEASE GIVE ME SOME TIPS AS TO THE POSSIBLE CAUSES OF THE PROBLEM THAT I MAY BE GUIDED IN FINDING THE SOLUTION BEFORE I HIRE A REPAIRMAN.THANK YOU AND MORE POWER.

JESS

Posted by on

Ad

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Guru:

    An expert who has written 7 tips or uploaded 3 video tips

  • Master
  • 587 Answers

If you already had the coils and filter cleaned and the blower is OK, that only leaves the refrigerant charge.
You are probably low on refrigerant.

Posted on Aug 25, 2009

Ad
  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

It has a undercharge or lack of refrigerant.

Posted on Apr 17, 2013

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 26 Answers

SOURCE: MY AIRCON IS BUILDING UP SOME ICE

Sounds like it's low on charge, dirty coil. Is this a ductless unit or window?

Posted on Jul 26, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I am asking for the code of kolin tv for chunglap remote controler thank you.


0281,0288,0285. Try these codes. If you wish to get more details; check the sites linked here. It has set-up code list & set-up procedure to many popular brand remote controls. Common set-up codes to check with TVs and other devices are given, in the order of the "device's brand name list" in alphabetical order. Pull up older posts. Surf the site with patience. Surf the sites by type in the brand name to your set, in its search box.
http://electronicshelponline.blogspot.com/
http://remotesearch.blogspot.com/
http://electro-medical.blogspot.com/
http://electrohelponline.blogspot.com/

Dec 09, 2014 | Olevia Kolin DLT2711M 27 in. LCD...

2 Answers

P7 error on screen


Try to Replace the sensor/ evaporator.

Aug 28, 2013 | Heating & Cooling

1 Answer

I have a Universal Remote Control model huayu rm-68e+ and lost my manual and i need it for my kolin tv can anyone know the code for my Kolin TV in these universal remote brand tnx


If you wish to get more details, check this site. http://electronicshelponline.blogspot.com/ Pull up older posts there. Setup code list and setup proceedings to many popular brand remote controls are given. Two digit, three digit, four digit and five digit setup code list to different models remote controls are given. If you search the site in Timeslide option, which can be selected from the drop down list at the top left of the display window, it will be easy to locate the related post. You can also do a search by type in the brand name and model number to your device into its search box at the top right of display window. Check this link too. http://electrohelponline.blogspot.com/.
Don't mind about the brand name of remote control. Look for codes to your TV brand, whether it is 3 digit, 4 digit or 5 digit; whatisover.

May 02, 2013 | Televison & Video

1 Answer

How to set taiyo aircon remote to daikin aircon


Set-up (Programming) procedure is too much to type in here, and is not practical and it will differ brand-to-brand remote controls. If you wish to get more; check the sites linked here. It has set-up code list & set-up procedure to many popular brand remote controls. One among it has general set-up codes to check with TVs and other devices are given, in the order of the 'device's brand name list' in alphabetical order. Pull up older posts. Search the sites by type in the brand name to your device in its search box at the top right part of the display window. It will help you to find the relative post easily.
http://remotesearch.blogspot.com/
http://electronicshelponline.blogspot.com/
http://electrohelponline.blogspot.com/

Mar 23, 2013 | Televison & Video

1 Answer

Hi i need to know what size window air con for a room 30sq meters cooling onjy and what model


Hello there.. :) your room 30 sq. meters needs 2 - 2hp window type aircon as computed. But you can consider the purpose of putting up the aircon and how many occupants will stay.. :0
For the model:
NATIONAL, 2HP, Model CW-1808VPH 2HP LG Window Type Aircon Manual 2HP Koppel Aircon w/ remote model: KWR-18R1
or check the internet for other models that you want.. :)

Feb 03, 2011 | Heating & Cooling

1 Answer

My window type aircon compressor run for 5 min,then stop for 4min,then run again for only 5 min even if the thermostat is set to the coolest setting and the the room temperature is higher than 30deg.C.it...


I have the same problem w/my CW-XC122VU. Other symptom is that the thermostat setting does not work in this "poltergeist" mode. After the problem went away by itself, then re-occurred, I notice it tracks the level of the water in the pan. A full pan of water will trigger poltergeist-mode, so I suspect some control or sensor is being shorted. The posted solutions ("transformer hum" or "broken on/off switch" are off the mark and generally unhelpful). We are not alone, though...the problem is observed in many Panasonic and Quasar window A/C units.

May 18, 2010 | Panasonic Heating & Cooling

1 Answer

MY AIRCON IS BUILDING UP SOME ICE


Sounds like it's low on charge, dirty coil. Is this a ductless unit or window?

Jul 26, 2009 | LG Heating & Cooling

3 Answers

WATER LEAKING FROM MY SPLIT TYPE LG AIRCON


1. Do not set the aircon too low temperature in overcast weather, this will cause ice ups and water dripping. Optimal comfort zone temperature is 24c.
2. You need to open the grill cover on the front of the aircon which unclips either end left and right with a finger pressure. You will find two filters which can slide out and should be cleaned. First tap them together to remove dust, then you can wash them with mild soap and cold water.
3. There is the third possibility that an insect has made a nest in the drainpipe. You should look on the outside of the building and locate a plastic drainpipe. You can either blow into this pipe with your mouth or get a blower. This will unblock any restriction in the drainpipe.
Goodluck and ratemeplease.

Mar 19, 2009 | LG LSC121PMA Split System Air Conditioner

1 Answer

Blueway air conditioner not fully cooling


Check the radiator for dirt, and check if the radiator fan is functioning. Do you notice any wetness or ice build up on the outside copper pipes. If so, suggest calling a refrig. tech. to add gas. The gas used is R22 on most aircons.

Feb 02, 2009 | Heating & Cooling

2 Answers

Kolin window type aircon shuts off by itself


This may be due to the size of the room. The master bedroom may be smaller than the living room? The unit is therefore reaching setpoint temperature and cycling (shutting off)? Or it could also be a faulty thermostat.

Jan 23, 2009 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

1,094 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2514 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions