1 Answer

Fan is so low, no water in roof, cool but not cold

Modle # 57915.751 the air is cool but not cold, water never runs off camper, and the fan is so low you can hardly hear it run.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 398 Answers

Clean the coils with acid [foamagator] oil the fan motor. click the fan and pay close attn to see if it changes. the blower switch may be bad. if you here it change speeds , you may need to put freon in it....good luck sawdust46

Posted on Jul 25, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Why is my roof rv a/c leaking condensate water inside Pop Up


if everything has been cleaned properly, is trailer level. good luck!

Nov 04, 2015 | Heating & Cooling

2 Answers

My Dometic Rooftop 15000 BTU Model 459516.701CO will come on and run and then shut off it continues to cycle within minutes of shutting off it is controlled by a Dometic Comfort Control Center 2...


THE OUTSIDE FAN MOTOR MIGHT NOT BE WORKING CAUSING THE COMPRESSOR TO GET HOT AND TRIP THE INTERNAL OVERLOAD IN THE COMPRESSOR - IF THE UNIT IS LOW IN FREON SAME RESULTS - WHEN UNIT IS FIRST TURNED ON DOES IT BLOW COLD AIR OR DOES THE AIR NOR FEEL COOL - JUST COOL AIR COULD BE LOW FREON - COLD THEN WARMS UP IS FAN PROBLEM

Jun 30, 2014 | Dometic Rooftop RV Air Conditioner

1 Answer

I have a 2006 Gulfstream Cavalier 8'x 32' Fema Travel Trailer with a Dometic Duo Therm AC unit which I have recently replaced the fan motor on. Had the dealership bench test motor prior to lea


There is ice forming on the evaporator coils. This is either from a low freon charge or a leak in the seals or windows and doors. Could also be that the drains are not working and water is building up and freezing

Oct 10, 2012 | Dometic Heating & Cooling

1 Answer

Where is the drain?


There are grooves on both sides of ac unit on a camper and it drains down the roof to a little gutter that travels the water towards end of camper and drains. Most of the time down the side of camper, but if these Grove are stopped up it will not allow it to drain and cause it to overflow inside camper. If filter is very stopped up or evaporator coil is stopped up, fan not running, low on refrigerant, or having the thermostat set way to low can cause it to freeze up and when this water thaws out it is too much for the drain to handle and also ice could be sticking being the drain pan melting causing it to go in your camper. I would check filter and those drain grooves first.

Sep 17, 2012 | Coleman Mach 15 Air Conditioner

2 Answers

I have a jayco pop up camper with a Duo-Therm BriskAir roof top a/c. im having problem with it leaking water inside of the camper? Is there a drain hose? Or wat do u think is wrong?Thanks


Yes there are drain holes in base of upper unit (on roof), which may be plugged. Couple of questions though to see if we can better troubleshoot this for you.
-Do you remember seeing water (condensation) running off roof before when AC was used?
-Have you cleaned filter inside at ceiling lately?

May 17, 2011 | Dometic Rooftop RV Air Conditioner

1 Answer

We have a 77 kountry aire bumper camper with roof air, we went camping and the unit cooled the camper really good then it just didn't seem very cool after checking it found the compressor was not kicking...


yes left the fan running and it did not kick on, checked the fins when we found it was not cooling there was no frost, do not no if would start again after sitting for hours it was so hot we just packed up and came home will have to try that when we get it somewhere to plug it in

Jul 31, 2010 | Dometic Rooftop RV Air Conditioner

1 Answer

Fan runs but no cool air. I don't think compressor is kicking in. Thermostat is working because when I adjust temp to be below or equal to air temp, AC unit turns on. When air temp drops as trailer cools...


Have you cleaned the unit? The condenser coil? The filter? The evapartor coil? Sounds like an airflow problem. You need to clean these areas. You can clean the condensor coil with water hose and a coil brush you can get at the hardware store. Clean the evaparator with the same brush. YOU can use a hairbrush if you don't have anything else. But make sure you go up and down on the fins on the coils not sideways. You might check your blower fan for dirt also. Good luck I hope I helped you. Could also be low on charge but first try cleaning.

Jun 28, 2010 | Heating & Cooling

1 Answer

I have a 1.5 hp kelvinator wall mounted air cond.It has three button (cool,fan,and dry)If I want to get the room really cold what is the best button to push


Hi,
The best button to push for that is the cool button, then turn the thermostat all the way to cold.
The fan button will only move air around and will do no cooling.
The dry button is for dehumidification, in this mode the unit will run a low speed fan over the cooling coil to take the water out of the air.

So for cooling your best option is to push the cool button and crank down the thermostat...

Heatman101

Jan 11, 2010 | Heating & Cooling

1 Answer

High cool not working


Compressors on these units runs at only one speed. The change to high cool is only a change in blower speed moving air faster over the cooling coil. I would have the running capacitor for the fan motor checked. A bad capacitor can cause your type of problem. The other problem could be that the high speed winding in the fan motor is bad. Try it operation in the fan only position through the two speeds. If it works in the low and high speed for fan only your problem could be in the selector switch.

Jun 23, 2008 | Dometic Rooftop RV Air Conditioner

Not finding what you are looking for?
Dometic 57915531 Air Conditioner Logo

Related Topics:

208 people viewed this question

Ask a Question

Usually answered in minutes!

Top Dometic Heating & Cooling Experts

Bill Long

Level 3 Expert

587 Answers

Donni Steen

Level 3 Expert

659 Answers

mike cooper

Level 3 Expert

884 Answers

Are you a Dometic Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...