FIXING ERROR

Posted on Aug 13, 2017

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 2 Answers

SOURCE: konica minolta bizhub 350

• The Fusing Roller Sub Thermistor does not
detect the required temperature within 30 sec.
after a warm-up cycle has begun; therefore, the
copier does not complete the warm-up cycle.
• The temperature of the Fusing Rollers does not
reach the required level even after the set period
of time has elapsed during a warm-up cycle.
1
Check that the H1[ fuser lamp] comes on when the Main Power
Switch is set to ON, and correct or replace as necessary.
- -
2
Check that the H2 comes on when the Main Power
Switch is set to ON, and correct or replace as necessary.
- -
3
Check the installation of the TH1 and the TH2, and
correct or clean as necessary.
- -
4
Check the operation of the TH1.
Remove CN80 (4P), and then check that the resistance
across CN80-2 and -3 on the Thermistor is
infinity.
- -
5
Check the operation of the TH2.
Remove CN81 (4P), and then check that the resistance
across CN81-2 and -3 on the Thermistor is
infinity.
- -
6
Check the continuity of the H1.
Correct or replace as necessary.
- -
7
Check the continuity of the H2.
Correct or replace as necessary.
- -
8 Change PU1 - -
9 Change PWB-A

Posted on Nov 19, 2007

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Konica minolta 206 call c3452 - Konica Minolta Office Equipment & Supplies


FIXING HEAT UP ERROR

RESET BY OFF AND ON BY HOLDING UTILITY BUTTON OR RESET BUTTON

May 15, 2017 | Konica Minolta Office Equipment & Supplies

2 Answers

Why is the machine showing all the time code c-3452


If you wish to get some details; check the site linked here. Pull up older posts......
http://electro-medical.blogspot.com/

Jul 02, 2016 | Konica Minolta bizhub C450P Laser Printer

1 Answer

How do I fix error message C3452?


It is most likely your fusing unit. Part number 9J06 R706 00 .

If you have had any power surges recently, meaning lightning struck your building and something else was hit. It could be the main board. You need to put a surge protector on this machine either way.

Oct 03, 2014 | Konica Minolta Office Equipment & Supplies

1 Answer

How to rest a C3452 error code on a minolta C300


try a trouble reset turn the machine off hold utility/counter power machine on select trouble reset reboot machine

Aug 17, 2014 | Konica Minolta Bizhub C300 All-In-One...

1 Answer

Error C3452


1. Turn OFF the main power switch.
2. Turn main power switch ON while pressing the Utility/Counter key.
3. Touch [Trouble Reset].
4. Check to make sure that [OK] is displayed and the it has been reset.
5. After turning off the main power switch, turn it on again more than 10 seconds after and check if the machine starts correctly

if the code comes back replace the fuser, continue to reset can cause fires.and that would ruin a perfectly good day

Jan 29, 2014 | Konica Minolta Bizhub C300 All-In-One...

1 Answer

Error c3452


error c3452 is fusing warm-up failure.
first do trouble reset.
second, check H1 or H2
third, check TH1 and TH2
four, change new fusing unit
five, change PU
six, change PWB-A

Sep 14, 2013 | Konica Minolta bizhub 350 All-In-One Laser...

2 Answers

How and where to solve /fix error code C-D301 on bixhub c250


here is the link
http://www.ebookbay.com/ebook/938/konica-minolta-bizhub-c250-sm
if you have any problem contact me.

Download

Dec 06, 2011 | Konica Minolta bizhub C250 All-In-One...

2 Answers

C3452


hi ali... the problem with your mfp is fixing uunit warm up failure... try to perform trouble reset... turn off the machine, then hold press the utility/ counter... konica minolta logo appears... press 3, type eight 0's then then tuoch "end" then touch "trouble reset"( note: dont touch other menu displayed on screen because you might get another problem.) then the machine will re-statr.....If there is an abort code, there its time for you to change the fixing unit.... ( if you know electronics try to check the heater lamp and thermostat using a multitester, check if there is a continuity inthe both ends...)

Apr 29, 2011 | Konica Minolta bizhub 350 All-In-One Laser...

3 Answers

Error code c 3452 on ineo 250+


develop ineo 250 machine error comes c3452
how i solve this

Nov 21, 2010 | Konica Minolta Office Equipment & Supplies

Not finding what you are looking for?
Office Equipment & Supplies Logo

Related Topics:

47 people viewed this question

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman  J Weimar Jr
Norman J Weimar Jr

Level 3 Expert

6161 Answers

Ben
Ben

Level 2 Expert

108 Answers

David Burkhart
David Burkhart

Level 2 Expert

210 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...