1 Answer

My MQ3-35 Grundfos pump will run for a few seconds after I turn it on, but then it shuts down and will no longer turn on automatically. Is there a pressure sensing switch that may need to be replaced?

The pump keeps my system pressured and usually turn on a few seconds after opening a tap in the house.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • Plumbing Master
  • 45,653 Answers

The pressure switch appears faulty
have it checked /replaced

Posted on Apr 25, 2017

Testimonial: "Thanks Bill."

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Grundfos water pump MQ3-45B. Will stop after frequent use. I have to turn it off and on to reset it. Control panel?


I would first check to see if any valves are partially closed, increasing the run time of your pump and causing over heating. Next I would check for any possible obstructions to water flow.

Grundfos pumps are designed to shut down when they are at risk of overheating and burning out which requires a manual reset. This can also be caused by insufficient water in the system, so you may want to bleed out any air that may be in it.

May 03, 2015 | Grundfos Plumbing

1 Answer

Grundfos MQ 35 won't run


Sounds like the discharge is plugged. You can get the manual at: http://rainwatercollection.com/download/Grundfos-Manual.pdf

Jan 24, 2014 | Plumbing

1 Answer

I have a problem with mq booster pump every 10 seconds kicks back and kicks on i am check the showers no leaks everything is ok please tell what can be a problem


Grundfos said the problem of on off every few seconds was air in the line. Then

later admitted it was the control unit. After replacing two units in 2 yrs I replaced

it with a standerd pump pressure switch.....Runs fine

Nov 17, 2011 | Grundfos MQ3-35 3/4 HP Pressure Booster...

1 Answer

Grundfos JPF4A pump. takes a long time to get up to prime then once it kicks in after running water it gets to 50 shuts of but drop pressure instantaneously and kicks back in again. The constant on off...


The check valve is bad. When the system builds up pressure and shuts off the check valve prevents water from dropping back down the well line. When the check valve goes bad water drops back down the well line and siphons water back out of the well tank causing the switch to kick on and off constantly. The check valve will between on the well line coming from the drop pipe. It may be making a constant rattling noise as pump is running. Replace the check valve and you should be fine. Also check the pressure in bladder tank it should be 2psi below the "cut-in" pressure for the switch.
RJ

May 22, 2011 | Grundfos Plumbing

1 Answer

I have a grundfos mq 35 pump to boost pressure in my hot and cold system. due to loss of water recently pump ran dry and shut down. when water returned the system was restarted and pump reset. we now get...


There was possibly some damage done to the pump while it was operating dry and it in now not able to deliver the required flow of water. Pumps wear very quickly when allowed to run dry, even for a short time.

Jan 02, 2011 | Grundfos JPS4 1 HP Pressure Booster Pump

3 Answers

Grundfos Pump Wont Stop Running


Close the outlet valve then turn electrical switch on manual for a few seconds until any air is pushed out then open the valve and return electrical switch to automatic.

Aug 07, 2009 | Grundfos JPS4 1 HP Pressure Booster Pump

2 Answers

My Grundfos JPS4 1 HP Pressure Booster Pump keeps coming on for a


SOUNDS LIKE YOU HAVE A LEAK DOWNSTREAM PROBABLY UNDERGROUND. THE PUMP HAS NO REASON TO COME ON EXCEPT TO BUILD THE PRESSURE BACK UP. HOPEFULLY YOU HAVE A GAUGE IN THE DISCHARGE LINE YOU CAN WATCH IT DROP AFTER THE SYSTEM SHUTS OFF. HOPE THIS HELPS, JODY

Apr 27, 2009 | Grundfos JPS4 1 HP Pressure Booster Pump

Not finding what you are looking for?
Plumbing Logo

Related Topics:

44 people viewed this question

Ask a Question

Usually answered in minutes!

Top Plumbing Experts

Donni Steen

Level 3 Expert

659 Answers

Brad Brown

Level 3 Expert

16210 Answers

Tom Chichester

Level 3 Expert

36514 Answers

Are you a Plumbing Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...