Question about Heating & Cooling

Open Question

I have a Technikka single split aircon that shuts down on an E6 error. Cant find any info on this units error codes.

Posted by Anonymous on

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 400 Answers

SOURCE: WATER LEAKING FROM MY SPLIT TYPE LG AIRCON

1. Do not set the aircon too low temperature in overcast weather, this will cause ice ups and water dripping. Optimal comfort zone temperature is 24c.
2. You need to open the grill cover on the front of the aircon which unclips either end left and right with a finger pressure. You will find two filters which can slide out and should be cleaned. First tap them together to remove dust, then you can wash them with mild soap and cold water.
3. There is the third possibility that an insect has made a nest in the drainpipe. You should look on the outside of the building and locate a plastic drainpipe. You can either blow into this pipe with your mouth or get a blower. This will unblock any restriction in the drainpipe.
Goodluck and ratemeplease.

Posted on Mar 19, 2009

  • 1 Answer

SOURCE: the kohler steam unit keeps shutting down prematurely

I've been struggling with this exact error for the past week and fixed it last night. The Error 5 message was misleading in my case and actually was caused by the steam outlet inside the shower and, even after replacing the entire unit and getting the same error, i fixed it in two seconds. Since this was one of the posting i encountered during my frantic searches, i thought i would come back and share my blog posting on this error and my fix:
http://fixitben.blogspot.com/2010/01/kohler-k-1658-240v-steam-generator-and.html

Posted on Jan 05, 2010

  • 1 Answer

SOURCE: ERROR CODE CH5 AIRCON SPLIT LG

This error is a communication error between your indoor and outdoor unit. You can try turning the breaker off for a few minutes and restart the unit. However if that does not work its best suggested to have an authorized HVAC technician service the unit.

Posted on Mar 12, 2010

hvac1960
  • 2133 Answers

SOURCE: Error code E6 Pioneer Split

E-6 Outlet pipe sensor open/short circuit. Replace it.

Posted on Jan 01, 2011

hvac1960
  • 2133 Answers

SOURCE: indoor unit flashes 5 times. error code meaning?

E-5 -Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4

Posted on Jan 03, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

3 Answers

What is error e6


e6 error air conditioner Questions & Answers - Fixya

www.fixya.com > Forum > Tags
Find solutions to your e6 error air conditioner question. Get free help, tips & support from top experts on e6 error air conditioner related issues.

air conditioner e6 code Questions & Answers - Fixya

www.fixya.com > Forum > Tags
...one inverter 12k I have a DeLonghi one inverter and when I want to turn On the heater then the code error display E6 and the error code is Communication ...

1-Time Flash & E6 error troubleshooting, part 1 of 3 for ...

? 3:04
https://www.youtube.com/watch?v=sYNN1Rvc7r0
Dec 18, 2012 - Uploaded by MitsubishiHVAC
1-Time Flash & E6 error troubleshooting, part 1 of 3 for Mitsubishi Electric .... Ductless Air Conditioner ...

Jan 23, 2016 | Heating & Cooling

2 Answers

Error code e6 what does that mean air conditioner will not start


DeLonghi CF210 Portable Air Conditioner Error code e6 ...

www.fixya.com > ... > DeLonghi CF210 Portable Air Conditioner
DeLonghi CF210 Portable Air Conditioner, error code e6 related issues. Get free help, solutions & advice from top DeLonghi experts.

Error e6 displaying on single split model one - Fixya

www.fixya.com/.../t4492271-error_e6_displaying_single_split_model
Apr 5, 2010 - Question about DeLonghi CF210 Portable Air Conditioner ... then the code error display E6 and the error code is Communication malfunction.

DeLonghi fix e6 error Air Conditioners Questions & Answers ...

www.fixya.com > Forum > Tags > fix e6 error > Air Conditioners
DeLonghi air conditioners fix e6 error related questions and answers. ... DelonghiFX400eco error code I Have the above air con unit 18 months old the cooling ...

DeLonghi CF210 Portable Air Conditioner Error code e6 split


Jan 01, 2016 | DeLonghi Heating & Cooling

1 Answer

Why my unit keep shutting off after few seconds and then turbo light keep on flashing?


Operation =
Flashing Display Timer = Yes
Turbo =
LED Display = E1
Explanation and Checking points = Indoor unit room thermistor error - Open or Closed Circuit - Check and replace if required

Operation = Yes
Flashing Display Timer = Yes
Turbo =
LED Display = E2
Explanation and Checking points = Indoor unit pipe thermistor error - - Open or Closed Circuit - Check and replace if required


Operation =
Flashing Display Timer =
Turbo = Yes
LED Display = E3
Explanation and Checking points = Indoor unit fan motor malfunction - Check and replace if required


Operation =
Flashing Display Timer = Yes
Turbo = Yes
LED Display = E6
Explanation and Checking points = EPROM error - Check and replace PCB if required


Operation = Yes
Flashing Display Timer = Yes
Turbo = Yes
LED Display = Flashing
Explanation and Checking points = Option code error - Check and input new option code if required via wireless remote controller


Operation = Yes
Flashing Display Timer =
Turbo = Yes
LED Display =
Explanation and Checking points = Outdoor unit temperature sensor - Open or Closed Circuit - Check and replace if required

Jun 18, 2014 | Samsung AQV36JA Classic 36000 BTU Single...

1 Answer

Sharp Air Conditioner error E6


Checked out door unit is not block with dust.If yes then cleaned with water.

Apr 23, 2014 | Sharp Heating & Cooling

1 Answer

Display error code E6


E6 is a comms error try turning the power off at the isolator and reset everything. if it comes back you might have a lose interconnecting wire between the indoor unit and outdoor unit

Apr 15, 2014 | Mitsubishi Heating & Cooling

1 Answer

How to reset the error code on daikin aircon


more info needed. try fixing the problem then turn unit of at the main power wait for 10 mins then turn on? whats the error code?

Nov 06, 2010 | Cfm Daikin R410a Split System Air...

2 Answers

Indoor unit flashes 5 times. error code meaning?


E-5 -Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4

Apr 17, 2010 | LG LS-L1210CL Mini Split Air Conditioner

1 Answer

Error e6 displaying on single split model one inverter 12k


I have a DeLonghi one inverter and when I want to turn On the heater then the code error display E6 and the error code is Communication malfunction. So can you tell me how can I fix it

Apr 05, 2010 | DeLonghi CF210 Portable Air Conditioner

2 Answers

Getting an E6 error code mrslim


could someone please tell me what an e6 error code on a Mr. Slim mini split means?

Nov 06, 2008 | Mitsubishi Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

22 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2461 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...