Question about LG DLG5932W Gas Dryer

1 Answer

Does not always heat - LG DLG5932W Gas Dryer

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 6,784 Answers

Note: Normal drying time for a dryer is about 45 minutes (some may take up to an hour).

1. Venting
Make sure the dryer vent hose, as well as the rest of the vent duct, is not clogged.

Unless regular maintenance is performed, chances are there is a lot of lint accumulated inside the dryer. This might affect the drying time and could be a fire hazard. Make sure to have your dryer cleaned regularly. Because this might involve taking most of the dryer apart, it is recommended to have a qualified appliance repairman perform this task.

2. Thermostat
There are a couple of cycling thermostats inside the dryer. If one of them breaks down, it might affect the dryer's performance. Replace the defective thermostat.

Posted on Jul 25, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

When em heat is on my outside unit runs but when not on em heat it doesn't. Which setting is best to use?


Has this always been this way? When the emergency heat is on the outside unit shouldn't run. When in normal heat, no emergency heat, the outside unit should be running unless the temperature is below the balance point ( usually around 35 degrees). If this has always been this way and the outside temperature is above 40 degrees you might have your 1st stage and 2nd stage wires switched.

Nov 27, 2016 | Heating & Cooling

1 Answer

What can i check to see why my maytag bravos dryer isnt drying?


[Always disconnect the dryer from any power source before checking.] Dryer heating circuits have several parts in the series circuit that must all work (kind of like a string of Christmas tree lights) so you'll want to check each one in that series. These likely include the motor switch, timer switch, temperature selector switch, temperature controls/thermostats (usually three of these) and all connecting wiring plus the heating element. Of course, one should always make certain the dryer is receiving 220 volts power supply from the wall outlet before starting to troubleshoot the dryer. Most dryers operate with 110 volts, only using the 220 volts for the heater circuit. A dryer getting only 110 volts could run, but not heat. This doesn't happen often, but is always worth checking.

Aug 20, 2014 | Maytag Dryers

1 Answer

I am trying to install the new tx900ts in my house and i do not understand the wiring on it i have a old trane thermastat that has different wiring codes


PLEASE GIVE ME A RATING AND VOTE YOU NEED TO FIGURE YOUR WIRES WRITE IT ALL DOWN AT UNITS AND THE OLD STAT
common is different by installer so you gotta look at the units or you will blow out your transformer this wire will be blue or brown
24v always red
compressor always yellow
fan always green
reversing valve always orange
heat w1 always white
emergency heat will be either brown or black dependinting on installer if its a heat pump this it what you have but if its a gas system its much easier
red- 24 volt with a jumper already on the new stat
white- heat w terminal
yellow- cool y termina
fan green- g terminal
and common is optional with batteries so its not needed
if you need further help email pendletonheatandair@hotmail.com

Sep 20, 2010 | Heating & Cooling

1 Answer

Aux heat always comes on in heating (Ruud heat pump)


what type of system is it, if it's it Rheem the o/b needs to be set for B, if not check the freon charge, or thermostat, there will be a point where the aux. heat comes on when you turn it up, poss. only 4 degrees, is it a mercury stat or digital ?

Feb 01, 2010 | Ruud UAMB Air Conditioner

1 Answer

Dryer doesn't always run a full cycle or heat


the moisture sensor is probably bad

Oct 21, 2009 | Kenmore Dryers

1 Answer

Brivis Buffalo 85 ducted heating unit, fan is always on


On the unit outside there is a button that says "push man. pull auto" if it is set to push man then the fan will go constantly.

Sep 22, 2009 | Heating & Cooling

1 Answer

Ge profile harmony electric dryer doesn't always heat.


Remove back of dryer and take out the elament shield and replace element don't over strech it start at one side and work it around thank you for useing fixya rate me

Jul 16, 2009 | GE Profile Harmony DPGT750EC Electric...

1 Answer

Always in high heat


I am assuming this is an electric dryer.

1) Thermostat may have failed.
2) Element may have broken at one point and shorted to ground.

Please reply your specific model number and I can help further.

Jan 19, 2009 | Whirlpool LER5636P Electric Dryer

Not finding what you are looking for?
LG DLG5932W Gas Dryer Logo

Related Topics:

96 people viewed this question

Ask a Question

Usually answered in minutes!