Question about Heating & Cooling

1 Answer

My Mr heater (natural gas)runs about two minutes then clicks and goes out. Can restart but does the same thing

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • Heating & Co... Master
  • 75,235 Answers

Most likely you have a defective thermocouple

Posted on Dec 28, 2016

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Maxx heater lights all burners for aprox 20 sec blower fan starts flame goes out flame lights again for 20 sec never blows much heat ?


sounds like its not getting gas fast enough to keep burning,that happen to me and the gas line was to long of a run for enough gas keep coming. so I up the pipe runs real good the flame keeps burning, so you know you can only go 25 ft in half inch pipe then u lose your flame

Oct 24, 2014 | Mr. Heater Natural Gas Garage Heater -...

1 Answer

After running for a few minutes, my bottle top heaters start flaring and burning irregularly. The same thing happen when I hooked it up to another heater. Also when I turn the gas off it takes a lot of...


Are the propane tanks fitted with a pressure regulator?

The propane gas regulator is one of the most important parts of a propane gas system (or a compressed natural gas system as well).

The purpose of the regulator is to control the flow of gas and lower the pressure from the tank to the appliance(s) in the gas system.

The regulator not only acts as a control regarding the flow and distribution of propane (or CNS) but also as a safety barrier between the high pressure of the tank and the end use appliance(s).

Without it, you can cause serious damage to the appliance's gas valve and create a disaster- fire or explosion.

Nov 30, 2013 | Mr. Heater Model MH12TS - Single Tank-top...

1 Answer

New jandy LxI 400 natural gas pool heater makes a howlering sound which starts after it runs for about five minutes. The noise starts soft and continues to get louder. The noise is loud. Once I shut the...


Your bypass valve is bad. Probably because you did not pay attention to your water chemistry. It is located where the pipes enter the heater. You remove it from the side of the manifold that is outside the heater. It is not a difficult job. Just make sure your pump does not come on while the heater manifold is open!

Apr 16, 2011 | Jandy LXI 400 NATURAL GAS POOL HEATER -

1 Answer

I installed a Mr Heater 45,000btu heater in my garage, when I turn it on to fire, it fires for a moment, I get about a 3 inch flame for a moment and then it goes out. What do I need to do?


clean the flame sencor first check connections on flame sencor , check you have gas to heater check limits high and low jump then out one at a time see if it lights , or check pressure switch if fitted jump this out and check tubes to it

Jan 20, 2011 | Mr. Heater Natural Gas Garage Heater -...

1 Answer

Can the mr. heater mh80cv be converted to natural gas, and if so what do i need.thank you


Yes you can...but the manufacturer (Mr. Heater in Cleveland)stated you can find a MH80CV made for natural gas cheaper that than the cost of conversion. You can call them at 800-251-0001 if you need to hear it for yourself.

Jan 13, 2011 | Mr. Heater MH80CV

2 Answers

Mr. Heater Natural Gas Garage Heater - 45,000 BTU. Power 120 volt and 24 volt good. Thermostat calling for heat, but nothing happening??


Check for a fuse either in-line or on the circuit board. There should be 24 volts going to the thermostat. If not, you have either a bad transformer or a bad thermostat wire. Jump out the terminals that the thermostat wires are connected to. This should force the unit to fire. If not, bad circuit board.

Dec 23, 2009 | Mr. Heater Natural Gas Garage Heater -...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

27 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2458 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...