Question about Teledyne Laars Laars Lite 2 Pool Heater 325,000 Btu / Natural Gas

1 Answer

My laars swimming pool pilot light keeps going out and it makes a clicking noise when it fires up and the pilot light goes out? it has been going on and off alot recently but can work for weeks on end then goes out, sometimes it only lasts days. any ideas would be greatly recieved. Regards Daniel Wiseman

Posted by on

  • dan_wiseman Jul 21, 2009

    hi yeah i checked those, and put some wd40 on them. I have replaced the pilot light this morning again and it seems to be working now, although it wasn't quite right so i made it fit! We will see in the coming days/weeks to see if it will work!

  • dan_wiseman Jul 21, 2009

    we still have a problem, it seems fine when it lights up. I can switch it off, turn the themostate down and cut the flow out and it will fire up again everytime, but after a few hours/days/weeks it just shuts off! It just doesnt seem to make any sense, ive tried everything, could the piliot just be getting blown out? is it worth replacing the pilot itself?

×

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 139 Answers

Check power pile conections on gas control valve.it is the 2 wires that come from pilot asembly.if they are loose or have rust or oxidation this can affect pilot and cause intermittent outage. let me know

Posted on Jul 21, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How turn on pilot on teledyne laars series 2


turn gas valve to pilot hold down for 1 minute keep holdibg and light pilot hold for 2 minutes then turn to on

May 27, 2014 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

My laar hot shot natural gas pool heater pilot says lit but wont fire any more replaced pilot generator pilot that whole unit nice pilot but wont fire


problem isnt with the pilot generator. you have either an open safety withing circuit, lose wiring connection, or tstat issue

Aug 17, 2013 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Laars lite 2 pilot


make sure gas pressure is correct if ok see if the silver tube has a cobweb also make sure all connections are good

Sep 04, 2012 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Teledyne laars xe pool and spa heater


look inside on panel directions if not turn to pilot setting hold down button light under where small silver line goes under while holding down button when lit keep holding for about a minute then turn to on should stay lit if wont stay lit need new pilot generator

Jun 09, 2012 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

I have a laars swimming pool heater, there is gas coming into the valve unit but it will not pass the valve block to light the pilot light.


Disconnect the pilot tube from the valve and pass a thin wire through it to make sure it is not blocked. Spiders have been known to nest in tubes off-season. If the tube is clear and the gas still won't flow through then the valve block probably needs to be replaced. If the high temperature limit has been tripped the valve will have to be replaced as high limit safety does not reset.

Aug 13, 2009 | Teledyne Laars Laars Lite 2 Pool Heater...

2 Answers

Pilot lights but burner will not fire


what burner where on the oven or the cooktop, if its the oven it may need new gas valve w\ thermocoupler

Jul 07, 2009 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Pilot light on but heater will not start


check the high-limit switches. Under the inlet/outlet header. if either is open it will not allow you to fire up. my 150 degree switch was corroded and after jump9ng out, bam it worked.

May 25, 2009 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Lighting the pool heater


You will need to buy a new thermo couple 8.00 part from ace it is the little copper line close to piolet flame,it sences the piolet and allows the gas to open and feed,it is wore out,burned out,replace.

Mar 30, 2009 | Teledyne Laars Laars Lite 2 Pool Heater...

Not finding what you are looking for?
Teledyne Laars Laars Lite 2 Pool Heater 325,000 Btu / Natural Gas  Logo

571 people viewed this question

Ask a Question

Usually answered in minutes!

Top Teledyne Laars Pool & Spa Experts

Paul Carew

Level 3 Expert

2597 Answers

Jay Finke
Jay Finke

Level 3 Expert

1363 Answers

Bill Jordan

Level 2 Expert

372 Answers

Are you a Teledyne Laars Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...