Question about Honeywell Televison & Video

1 Answer

I have a Honeywell st9120u1011 11 fan timer Universal board and it is giving me code for 4 flashes on the light indicating the board locked out and you have any advice on what would be wrong with it

Posted by on


1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.


    An expert that got 20 achievements.


    An expert that got 10 achievements.

  • Honeywell Master
  • 74,999 Answers

Those blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit section inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power LED, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating procedure, to many popular brand TVs and other devices.
If blinks continue without any pause, the main board is faulty.

Posted on Dec 16, 2016


1 Suggested Answer

  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017


Add Your Answer

Uploading: 0%


Complete. Click "Add" to insert your video. Add



Related Questions:

1 Answer

Fujitsu Aircon model AST24PBA-W has green Timer light continuously flashing and red Operation light giving 5 flashes. Outside unit fan will not run. What does this code indicate has failed?

Most likely a faulty fan motor. You will need a tech to diagnose correctly as this uses a DC motor which has a circuit board inside so has very specific tests. Other possible faults for this code are compressor rotation error, CT abnormal or current trip all of which will need a tech to diagnose.

Nov 04, 2017 | Fujitsu Heating & Cooling

2 Answers

Wirred into system gas valve will not open

Possibility solenoid valve is not working u shud hear a click when it opens

Oct 05, 2013 | Honeywell ST9120U1011 Fan Timer Universal,...

1 Answer

FUJITSU Indoor Inverter ASTA09LCC/ASTA12LCC airconditioning - not cooling

If the operation button is flashing 8 times, the timer light should also flash 4 times in each sequence. This indicates a failure of the PFC circuit in the outdoor unit which basically means a faulty outdoor board and will have to be replaced.
If the operation light is flashing 8 times by itself, the indoor controller board may have a fault. You can normally test this by putting the mode on the remote to 'Fan' and checking that the controls otherwise work normally - louvers work as directed and fan speed changes correctly when selected on the remote.
Most likely the fault lies in the outdoor board but you should contact a tech to diagnose correctly.

Sep 24, 2017 | Fujitsu 18C1 Air Conditioner

1 Answer

Machine stopped mid cycle and green light flashing under green start button

Many modern washing machines display error codes if they detect a fault, but not all washing machines display a readable error code, some indicate an error by flashing, or lighting some of the lights.

Hotpoint, Indesit, Zanussi error codes

Hotpoint, Indesit washing machines and Zanussi washing machines are some common appliances that display coded error codes. On their more expensive models, they display readable error codes but basic models (without digital displays) use flashing lights to convey the error fault code.

If your washing machine malfunctions and you can see some of the lights flashing, or one or more option lights have lit up, then make a note of which lights are flashing and which option lights are lit. NOTE: the error code list engineers have only shows the option lights by number and not by name. Therefore you need to report the lights as LED 1 and 3, or 2 and 4 etc. and NOT "delay timer" and "extra rinse". Count the lights from the left (or from the top if in a column) and report as "led 1 and 3" etc.

No Option lights?

With basic washing machines that have no option indicator lights, count the number of flashes. For example, the door locked indicator may flash 7 times, pause, and flash another 7 times in a constant cycle which would indicate error code 7.

This information is vital, and needs mentioning when reporting a fault.

Jan 18, 2011 | Zanussi FJS1225W Front Load Washer

1 Answer

Indesit wd12 (old) timer just goes round without stopping. door light flashes 9 times, help!

Hi, this is the list of the Indesit wd12 error codes...
Error codes and their meaning..
f01 light 4, motor triac f02 light 3 motor, jammed/ tacho f03 lights 3&4 Ntc fault f04 light 2. pressure sw stuck on empty f05 lights 2&4, pressure sw stuck on full f06 lights 2&3, N/A? f07 lights 2&3&4 heater relay f08 light 1. heater relay f09 lights 1&4 eprom/setup error f10 lights 1&3, pressure switch not sensing f11 lights 1&3&4, pump/draining error f12 lights 1&2, communication error f13 lights 1&2&4, dryer ntc/ fan motor f14 lights 1&2&3, dryer heater f15 lights 1&2&3&4, dryer heater relay f16 N/A f17 light 4, door lock f18 light 3 comms error (3 phase motor) power board

Door flashing 9 times means 1&4 eprom/setup error

Dec 20, 2010 | Washing Machines

1 Answer

Gas valve opens and burner lights but the furnace blower does not start the blower will run in the on position. controlboard is a honeywell st9120c

Here is the specs for your board
Check the wiring to be sure you're getting all the inputs and proper timer settings.

It could be bad. (sometimes the fan relay goes bad)

Oct 28, 2010 | Honeywell Fan Timer Board St9120c 2010

1 Answer


Hi, you should be real close with the universal timer and the factory OEM. On the new control board, if you have 24 volts to the board, you should have 24 volts from R to ground or to Common. I know that on most all control boards the voltage in is 120volts as you will have terminals for L-1 and L-2 to run the high voltage controls from the board and all of the thermostat control terminals in a row, R,G,Y, W, C, and so on are 24 volts. 120 volts is stepped down to 24volts control and you say you have nothing out. Make sure you have 120volts in. You are calling this a timer board, is this a heat-pump defrost board with the 3 settings and pin to defrost the unit at 30,60,and 90 minute times? This is what it sounds like. If all was terminated per diagram, you would have the 24 volts required to fire this unit. These defrost timer boards require high voltage to them as well. Even though the board is a new board and you know for a fact that it is wired properly, it may be a defective board. I have seen this many times in my years as a tech. I have shorted new boards out by static electricity and by mis- wiring one. You can kill power and look at the back side of the board to see if this has happened. Sometimes you will find that they missed a solder point on the back side not completing a circuit through the board. To give you more ideas, I would need to see the diagram, or if you could send me the model, serial, and name of your unit. The board number would help also. Check out what I have said and get back to me on this. I will wait to hear.

Jun 06, 2010 | Heating & Cooling

Not finding what you are looking for?
Televison & Video Logo

Related Topics:

146 people viewed this question

Ask a Question

Usually answered in minutes!

Top Honeywell Televison & Video Experts

Brad Brown

Level 3 Expert

16802 Answers


Level 2 Expert

68 Answers

Ron Durham

Level 3 Expert

503 Answers

Are you a Honeywell Televison and Video Expert? Answer questions, earn points and help others