Question about Honeywell Televison & Video

1 Answer

I have a Honeywell st9120u1011 11 fan timer Universal board and it is giving me code for 4 flashes on the light indicating the board locked out and you have any advice on what would be wrong with it

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • Honeywell Master
  • 74,106 Answers

Those blinks [flashes] are fault indication (Error Codes). From the number of blinks occur at one time switch ON, you can get an idea about the faulty circuit section inside it. This will make repair easy. These are called blinking codes. Make sure about the exact number of blinking of the standby/power LED, by switching On & OFF the set, for at least two times. Count it carefully. If you wish to get some details, check the site linked here. It has details about blinking codes, and fault locating procedure, to many popular brand TVs and other devices.
http://electronicshelponline.blogspot.com/
If blinks continue without any pause, the main board is faulty.

Posted on Dec 16, 2016

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Wirred into system gas valve will not open


Possibility solenoid valve is not working u shud hear a click when it opens

Oct 05, 2013 | Honeywell ST9120U1011 Fan Timer Universal,...

1 Answer

Heil fan control board replace


http://www.allpartsheating.com/1014460.html

May 04, 2013 | Honeywell International Heil Quaker...

1 Answer

Machine stopped mid cycle and green light flashing under green start button


Many modern washing machines display error codes if they detect a fault, but not all washing machines display a readable error code, some indicate an error by flashing, or lighting some of the lights.

Hotpoint, Indesit, Zanussi error codes

Hotpoint, Indesit washing machines and Zanussi washing machines are some common appliances that display coded error codes. On their more expensive models, they display readable error codes but basic models (without digital displays) use flashing lights to convey the error fault code.

If your washing machine malfunctions and you can see some of the lights flashing, or one or more option lights have lit up, then make a note of which lights are flashing and which option lights are lit. NOTE: the error code list engineers have only shows the option lights by number and not by name. Therefore you need to report the lights as LED 1 and 3, or 2 and 4 etc. and NOT "delay timer" and "extra rinse". Count the lights from the left (or from the top if in a column) and report as "led 1 and 3" etc.

No Option lights?

With basic washing machines that have no option indicator lights, count the number of flashes. For example, the door locked indicator may flash 7 times, pause, and flash another 7 times in a constant cycle which would indicate error code 7.

This information is vital, and needs mentioning when reporting a fault.

Jan 18, 2011 | Zanussi FJS1225W Front Load Washer

1 Answer

Indesit wd12 (old) timer just goes round without stopping. door light flashes 9 times, help!


Hi, this is the list of the Indesit wd12 error codes...
Error codes and their meaning..
f01 light 4, motor triac f02 light 3 motor, jammed/ tacho f03 lights 3&4 Ntc fault f04 light 2. pressure sw stuck on empty f05 lights 2&4, pressure sw stuck on full f06 lights 2&3, N/A? f07 lights 2&3&4 heater relay f08 light 1. heater relay f09 lights 1&4 eprom/setup error f10 lights 1&3, pressure switch not sensing f11 lights 1&3&4, pump/draining error f12 lights 1&2, communication error f13 lights 1&2&4, dryer ntc/ fan motor f14 lights 1&2&3, dryer heater f15 lights 1&2&3&4, dryer heater relay f16 N/A f17 light 4, door lock f18 light 3 comms error (3 phase motor) power board

Door flashing 9 times means 1&4 eprom/setup error

Dec 20, 2010 | Washing Machines

1 Answer

Gas valve opens and burner lights but the furnace blower does not start the blower will run in the on position. controlboard is a honeywell st9120c


Here is the specs for your board
http://customer.honeywell.com/techlit/pdf/PackedLit/69-0781.pdf
Check the wiring to be sure you're getting all the inputs and proper timer settings.

It could be bad. (sometimes the fan relay goes bad)

Oct 28, 2010 | Honeywell Fan Timer Board St9120c 2010

1 Answer

TROUBLE REPLACING OEM TIMER - UNIVERSAL ELECTRONIC FAN TIMER


Hi, you should be real close with the universal timer and the factory OEM. On the new control board, if you have 24 volts to the board, you should have 24 volts from R to ground or to Common. I know that on most all control boards the voltage in is 120volts as you will have terminals for L-1 and L-2 to run the high voltage controls from the board and all of the thermostat control terminals in a row, R,G,Y, W, C, and so on are 24 volts. 120 volts is stepped down to 24volts control and you say you have nothing out. Make sure you have 120volts in. You are calling this a timer board, is this a heat-pump defrost board with the 3 settings and pin to defrost the unit at 30,60,and 90 minute times? This is what it sounds like. If all was terminated per diagram, you would have the 24 volts required to fire this unit. These defrost timer boards require high voltage to them as well. Even though the board is a new board and you know for a fact that it is wired properly, it may be a defective board. I have seen this many times in my years as a tech. I have shorted new boards out by static electricity and by mis- wiring one. You can kill power and look at the back side of the board to see if this has happened. Sometimes you will find that they missed a solder point on the back side not completing a circuit through the board. To give you more ideas, I would need to see the diagram, or if you could send me the model, serial, and name of your unit. The board number would help also. Check out what I have said and get back to me on this. I will wait to hear.
Shastalaker7

Jun 06, 2010 | Heating & Cooling

1 Answer

My Hotpoint Aquarius WF430 1300 doesn't complete its cycle, it stops after the wash & doesn't go on to the rinse & final spin. It seems to "freeze" after the wash is finished as the lights remain...


If your lights are flashing, use these codes to pinpoint the error.

These codes are reading from the top neon down.

F01....OFF, OFF, OFF, Flash, OFF.
F02....OFF, OFF, Flash, OFF, OFF.
F03....OFF, OFF, Flash, Flash, OFF.
F04....OFF, Flash, OFF, OFF, OFF.
F05....OFF, Flash, OFF, Flash, OFF.
F06....OFF, Flash, Flash, OFF, OFF.
F07....OFF, Flash, Flash, Flash, OFF.
F08....Flash, OFF, OFF, OFF, OFF.
F09....Flash, OFF, OFF, Flash, OFF.
F10....Flash, OFF, Flash, OFF, OFF.
F11....Flash, OFF, Flash, Flash, OFF.
F12....Flash, Flash, OFF, OFF, OFF.
F13....Flash, Flash, OFF, Flash, OFF.
F14....Flash, Flash, Flash, OFF, OFF.
F15....Flash, Flash, Flash, Flash, OFF.
f16....OFF, OFF, OFF, OFF, Flash.
F17....OFF, OFF, OFF, Flash, Flash.
F18....OFF, OFF, ON, OFF, OFF. Fault on control board, check Eeprom.
these are the codes and this is what they mean

f01 light 4, motor triac
f02 light 3 motor, jammed/ tacho
f03 lights 3&4 Ntc fault
f04 light 2. pressure sw stuck on empty
f05 lights 2&4, pressure sw stuck on full
f06 lights 2&3, N/A?
f07 lights 2&3&4 heater relay
f08 light 1. heater relay
f09 lights 1&4 eprom/setup error
f10 lights 1&3, pressure switch not sensing
f11 lights 1&3&4, pump/draining error
f12 lights 1&2, communication error
f13 lights 1&2&4, dryer ntc/ fan motor
f14 lights 1&2&3, dryer heater
f15 lights 1&2&3&4, dryer heater relay
f16 N/A
f17 light 4, door lock
f18 light 3 comms error (3 phase motor) power board

also try checking this manual
http://imagebank.indesitcompany.co.uk/brochures_online/pdf/Hotpoint/Laundry/WFseries_19504110305_Jan05_book.pdf

Mar 05, 2010 | Washing Machines

4 Answers

Flashing lights indesit wil103


you will need to unplug the machine at the mains, give it two minutes and the auto door lock will release your duvet, however start saving the pennies as your pcb is knackered and you'll be looking at about £200 to fix it

Oct 25, 2007 | Indesit W 123 Front Load Washer

Not finding what you are looking for?
Televison & Video Logo

Related Topics:

38 people viewed this question

Ask a Question

Usually answered in minutes!

Top Honeywell Televison & Video Experts

Ron Durham

Level 3 Expert

471 Answers

The Knight
The Knight

Level 3 Expert

74106 Answers

Tom Chichester

Level 3 Expert

34102 Answers

Are you a Honeywell Televison and Video Expert? Answer questions, earn points and help others