First I think you should start by looking at the ignition system.
To find the fault please follow these steps:

  1. Removed the spark plug from the engine and re-attach to the Ignition HT Lead. Hold the end of the spark plug tip to a metal section of the engine, and turn over the engine (you might need a friend to help if your generator does not have electric start). If all is working correctly, you should see a strong spark, and the engine should run smoothly.
  2. If you do not get a spark, you next need to check oil level is at correctly level (to the very top as if about to flow out) and repeat step 1.
  3. If you still have no spark or it stops running within a few minutes of starting, disconnect the oil sensor wire (you will find it on the front coming from your engine just to the top left of the oil filler cap) and try step 1 again.
  4. Still not getting a spark? Then you need to replace your ignition coil. You can order one from us from our website on this page: http://www.generatorguru.com/sp-gg350/?sort=featured
If you are getting a spark, but still having trouble starting the Generator, there is most likely a fuel problem too. We can assist you with the next set of fault-finding tests if you need some help. Let us know how it goes. :)
http://www.generatorguru.com/ask-the-guru/

Posted on Dec 12, 2016

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I need a rectifier or avr for generac 3500 xl genarator


Ebay and various places including the maker..

  • VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR-GENERATORS ... www.ebay.com/sch/sis.html?_nkw=VOLTAGE-REGULATOR-3000-3500-WATT... VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR ... New listing 3500 Watt Generator AVR Automatic ... 3500W Generator AVR Automatic Voltage Rectifier ...
  • 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator ... https://sites.google.com/site/kltthtyz0i04cd/3500-w-3500-watt... Generac Guardian 22kW Standby Generator NG ... Previously Pay for Shop 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator Rectifier 3.5KW Generator AVR ...
  • How to test your Electricity Generator's AVR, Brushes and ... www.youtube.com/watch?v=tC_LrrZcx38
    • BY GENERATOR GURU
    • 9 MIN
    • 454K VIEWS
    2011-10-21 · Video embedded · When your electricity Generator stops producing power, ... How to test your Electricity Generator's AVR, ... Generac iQ: The Quietest Generator ...
  • Generac Power Systems - Home www.generac.com Generac manufactures the widest range of power products in the marketplace including portable, RV, residential, commercial and industrial generators.
  • Generac Guardian Generator Voltage Regulator Rectifier ... www.ebay.com/sch/sis.html?_nkw=Generac+Guardian+Generator+Voltage... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator ...
  • Automatic Voltage Regulator (AVR) for Generators portable.generatorguide.net/avr.html How automatic voltage regulator (AVR) works in portable generators: ... here you can see a reverse engineered Generac regulator that uses SCRs and UJT.
  • Diagnosing A Generator That Has No Power Output. - YouTube Youtube
    • BY THEDIYGUYDOTNET
    • 3 MIN
    • 150K VIEWS
    2012-11-12 · Video embedded · Diagnosing A Generator That Has No Power Output. ... How to test your Electricity Generator's AVR, ... Generac Portable Generator ...
  • GENERATOR Diagram & Parts List for Model 3500xl Generac ... www.searspartsdirect.com > ... > 3500XL GENERAC Generator-Parts GENERATOR Diagram and Parts List for GENERAC Generator-Parts model # 3500XL ... Generator rectifier Part #: ... Generator voltage regulator Part #: ...


  • Jun 28, 2016 | Generac Electrical Supplies

    1 Answer

    My Oman generator overheats and shuts down if I plug my battery charger in and have my air conditioning on and or coffee maker


    to start with with an air conditioner running (2000 +watts ) plus a coffee machine (1500 watts ) you are looking at 3500 + watts of power used from the generator
    the genset has to be of a minimum of 4500 watts to run full time with out over heating
    never mind what the rating says on the side, that rating is surge rated and the duty cycle is around 500 watts less than that figure
    So if your gen set is 3500 watts the power is at surge power and that will overheat the genset
    Of course you haven't mentioned the rating of the set , but overloading is the main reason for over heating

    Jun 06, 2016 | Electrical Supplies

    2 Answers

    I have a nikota 3500 watt generator and I am not getting any power from the generator. Motor runs fine just no power. Is there anything I can check.


    All Power America APG3535CN, 2800 Running Watts/3500 ...

    www.amazon.com/...Power...Generator/.../B000U0OJ...

    Amazon.com, Inc.I then call All Power and am told to give them one more day to get this worked out ....There is no styrofoam enclosure or crate to protect it, the generator is simply ...

    NIKOTA 3500 WATT GENERATOR - YouTube

    ? 0:58
    https://www.youtube.com/watch?v=NEeu9Y-0_KM
    Aug 27, 2011 - Uploaded by mamasboypowersports
    NIKOTA 3500 WATT GENERATOR. ... Diagnosing A GeneratorThat Has No Power Output. - Duration: 3:03. TheDIYGuyDOTnet 117,263 views.

    I have a nikota 3500 watt generator and I am not getting any ...

    www.fixya.com/support/t26062098-nikota_3500_watt_generator_am_not
    2 hours ago - I have a nikota 3500 watt generator and I am not getting any power from the generator. Motor runs fine just no power. Is there anything I can ...

    Generator outputs low variable voltage, ideas for troubleshooting ...

    www.smokstak.com > ... > Generators & Motors General Discussion

    Jan 20, 2016 | Electrical Supplies

    1 Answer

    Champion 3500 watt generator shuts down after 1 min. Not low on oil!


    You have a carburetor problem. Stuck float or clogged filter. Gas cannot get into the carb as fast as it is used. Letting it sit for a few minutes will allow the bowl to fill.

    Aug 02, 2012 | Champion 3500/4000 Watt Portable Generator

    1 Answer

    How do I connect 2 1850 watt coleman generators together to have at least 3500 watts to run my camping trailer?


    It wont work. Electricity does not work like that. you can't double the power just by doubling the watts or amps. there is a lot and lots of other things involved.
    I would rewire you camper so that half is run be one generator and the other half by the other generator... SO lights and fridge on one and plugs and heater on the other maybe...

    Aug 13, 2010 | Electronics - Others

    1 Answer

    Had to tickle the throttle on my yamaha 3500 watt


    You should have automatic or manual choke control. Try to find it and open it during start. After that you can close it if stable work is achieved.

    May 30, 2010 | Yamaha 4500 Watt Electric Start Generator...

    2 Answers

    Coleman 7300 rooftop air conditionor wont operate


    When they sit allot - sometimes the fan will stick.. Take the cover off,, turn it on and see if the fan is stuck.. Spin it by hand to free it up..

    Jul 09, 2009 | Dometic Rooftop RV Air Conditioner

    Not finding what you are looking for?
    Electrical Supplies Logo

    Related Topics:

    25 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top Electrical Supplies Experts

    Steve

    Level 3 Expert

    3287 Answers

    Gene Haynes

    Level 3 Expert

    5089 Answers

    Brad Brown

    Level 3 Expert

    15451 Answers

    Are you an Electrical Supply Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides

    Loading...