Question about Comfort Zone Heating & Cooling

Open Question

I have a comfort zone ceramic oscillating heater model number cz499r run for 1 minute and shuts off and will not turn back on LCD is blank

Posted by on

5 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

shastalaker7
  • 1515 Answers

SOURCE: cz 446 comfort zone ceramic heater shuts off

Hi, the problem you are having is the thermostat control, and dimming the lights is a indication of the neutral side of the control if faulty.It is drawing enough amps to make you're home lights blink, so I would stop using it now and if you are inclined to replace this control yourself I would. If this is something you would not care to take on, I would get an estimate for repair at a appliance repair store, compared to replacing the unit with a different one.I am sorry to tell you this, but it will only get worse and what I have recommend is for you're safety.
Sincerely,
Shastalaker7
PS Please keep me informed of the situation, as I would love to be of any help you may need.

Posted on Dec 05, 2009

  • 13 Answers

SOURCE: my comfort zone heater is cz499r with remote, I

I have had this problem before on some of those units. The fan control switch is faulty. You have to open the unit and locate the switch. One of the side panels covers it along with a shut off thermal switch and the ends to the heating elements. Use a multimeter to test both thermal switches one should be closed one should be open . The one that is open is the fan control switch, REPLACE IT with the exact match. I have bought them from Grainger for about $20. Don't hesitate to replace it. Test the fan by connecting both leads from that switch and energize the unit. Does the fan kick on? if not the fan is the issue, if the fan kicks on then replace the thermal switch. Be sure to get the switch that is normally open.

Posted on Dec 26, 2011

  • 157 Answers

SOURCE: My comfort zone heater will come on then

Possible failure in the control board has occurred or the tip over cut off switch is bad.

Posted on Dec 19, 2014

  • 946 Answers

SOURCE: I have an All-Pro 115,000 btu kerosene heater,model number, R115d(T)I can turn it on but it will only run for about 3 minutes, it shuts off and a big cloud of black smoke appears,

Is the fuel tank cap vent clear? Are you sure there's no water in fuel tank? don-ohio

Posted on Jan 05, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Comfort zone infrared heater runs for a few minutes a then completely shuts off


if unit runs ok for 3 to five minutes then completely shuts all power lamps off , then its hi temp limit sensor (safety) has been tripped , this usually goes out due to failure of main temp control , in point of fact contacts in temp switch literally weld them self's together and cant separate to allow heater to control temp

Oct 15, 2016 | Comfort Zone CZ1500WC Infra-Red...

1 Answer

Rattle


Usually it's the fan or fan motor, or the rotating motor making the noise. Usually you can pull it off or clean it...AND the bearings, which could be crudded up.

Dec 04, 2013 | Comfort Zone Cz488 Ceramic Oscillating...

1 Answer

I have a Comfort Zone cz20110 and I need help. The heater will turn on and blow out heat, but the display screen is blank. It was not blank when we first plugged it in however and I know there's a way...


i have a digital quartz infrared heater comfort zone cz20110. does the fan keep running all the time and when it reaches the temp to your room why doesn't it it shut off.

Jan 02, 2013 | Heating & Cooling

1 Answer

Why does my comfort zone infrared heater shut off after I turn it on? What modes does it have?


What is wrong with my Comfort Furnace heater if i have it turned off and it still keeps blowing ,Yet if i plug it back in it still comes on and i can turn it way down with it down on 55 and it will not shut of like it use to?

Oct 08, 2012 | Comfort Zone CZ1500WC Infra-Red...

1 Answer

Comfort Zone heater model: CZ2011C. Shuts completely off in two minutes


FYI...I have a customer that brought his Comfort Zone CZ2011C to me for service. It does exactly the same thing, just powers off after a few minutes of operation. I contacted the company and receive no help at all telling me that repair parts are unavailable. Really??? Absolutely the worst company I have ever dealt with in over 29 yrs of appliance repair....

Dec 25, 2011 | Comfort Zone CZ1500WC Infra-Red...

2 Answers

My comfort zone heater is cz499r with remote, I posted a comment earlier about my heater smoking and not turning on, my return date ended jan. 15 is there anything i can do? I got the heater from big lots!


What you have is a very dangerous situation. It may not be a newness smell. It may be the plastic melting. Many of the Comfort Zone heaters were recalled in December 2010. Search Google for Comfort Zone Heater Recall to see if your specific model was included


Big Lots has some great pricing and deals, but some of their electric appliances are Factory Refurbished Units. If that is the case, it is required that the box it came in must indicate that.

Jan 27, 2011 | Heating & Cooling

1 Answer

Cz 446 comfort zone ceramic heater shuts off


Hi, the problem you are having is the thermostat control, and dimming the lights is a indication of the neutral side of the control if faulty.It is drawing enough amps to make you're home lights blink, so I would stop using it now and if you are inclined to replace this control yourself I would. If this is something you would not care to take on, I would get an estimate for repair at a appliance repair store, compared to replacing the unit with a different one.I am sorry to tell you this, but it will only get worse and what I have recommend is for you're safety.
Sincerely,
Shastalaker7
PS Please keep me informed of the situation, as I would love to be of any help you may need.

Dec 05, 2009 | Honeywell HZ-338 Ceramic Compact Heater

1 Answer

I have a lasko tower ceramic heater that keeps shutting down.


mine does the same thing every year. I just clean out the dust from the vents on the back of the heater so the heater can breath otherwise it could get too hot and the safety fetcher kick in and makes the heater stop working.

Oct 19, 2009 | Tower Lasko 30 Inch Ceramic Oscillating...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

29 people viewed this question

Ask a Question

Usually answered in minutes!

Top Comfort Zone Heating & Cooling Experts

yadayada
yadayada

Level 3 Expert

75807 Answers

paulcarew

Level 3 Expert

2461 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Are you a Comfort Zone Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...