Sounds like someone needs to change out the thermostat control on your model. What is the model and serial numbers?
APPLIANCE 911

Posted on Dec 04, 2016

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 1035 Answers

SOURCE: I got a true refrigeration sandwich prep table it ...

Look for doors not properly closing, poor air flow over coil or something blocking air flow, improper freon level.
http://www.truemfg.com/pdf/InstallManuals/TPP_TSSU_TUC_TWT/tuc_english.pdf
check out this web site as it has a manual for your equipment. it has lots of good info. Hope this helps. If you need more help, let me know.

Posted on Jun 13, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

True gets too cold


If it doesn't respond to the adjustment on the temperature control I would think it has an improper refrigerant charge. You need to remove the existing charge and weigh in the new charge. It has to be exact for the temp control to respond and sense properly. Some times when the refrigerator is slowly losing its charge from a leak you will have long running times and the refrigerator will get too cold and then suddenly wont cool at all. Check the condenser to make sure that its plenty clean. An overheated system will cause long run time. Temp controls don't generally fail and I would be slow to just change it without looking the system over good for leaks. You may have to call someone in to check it out. Hope this helps and good luck.

Jul 08, 2014 | True GDM-69 Refrigerator

1 Answer

Why is the unit freezing? It is a TRUE TSSU-60-16.


Turn down the temp and move produce item closer to the front. The air exits the evaporator at around 28 degrees. Possible you need a thermostat.

Feb 04, 2013 | True TSSU-60-16-DS-ST-ADA Dual Sided...

1 Answer

Do I have to use a TRUE thermostat on my T-72?


The True thermostat sits on the evaporator in a piece of tube attached to the coil. If it won't switch off at your required temp even at position 1 you can use an air temperature type thermostat in it's place. It will sit in the same place but the sensing end will coil up behind the fan. Get a bar fridge thermostat and it'll adjust to your needs.

May 18, 2012 | True GDM-72 Refrigerator

1 Answer

The True brand commercial refrigerator at my job is entirely too cold. How do I adjust the temp? Beer is exploding!


You will need to adjust the thermostat.
The thermostat will be hidden at the bottom back of the fridge near the compressor.
You may need a screw a flat blade driver driver to adjust the themostat

Apr 01, 2011 | True TSSU-48-12 Refrigerator Commercial

1 Answer

My True sandwich unit has been going up in temp slowly for the last month. It is set to the coldest setting, and is holding temp around 46 degrees now. It goes up around a degree a day. Any idea what...


first place to look would be the freon level. It sounds like there is a slow leak and freon level is going down. Start there and let me know if I can help any further.

Feb 14, 2011 | True Sandwich Unit - TSSU-48-10

1 Answer

I got a true refrigeration sandwich prep table it will get down to temp. But as soon as it gets down to about 38 it will start frosting up all the way back to the compressor and by the next day it has...


Look for doors not properly closing, poor air flow over coil or something blocking air flow, improper freon level.
http://www.truemfg.com/pdf/InstallManuals/TPP_TSSU_TUC_TWT/tuc_english.pdf
check out this web site as it has a manual for your equipment. it has lots of good info. Hope this helps. If you need more help, let me know.

May 19, 2010 | True 598-TSSU608ADA SandwichSalad Unit 155...

1 Answer

We have a GDM-26 commerical coke machine. Only


If any of your drinks are freezing you need to adjust your temp setting. The suggested setting is 5. changing the temp setting basically tells the refrigerator to stop cooling when the temp hits a low degree, and to start cooling when it hits a high degree. This keeps your drinks not to hot, not too cold, but just right. If this doesn't work I would change the cold control altogether, it might've went bad. If you have a few minutes, locate the condensor fan (bottom) and make sure it is periodically turning on and off like it should.

Jun 08, 2009 | True GDM-12 Refrigerator Commercial

2 Answers

Runs out of hot water


I wonder if you have this problem below caused by a drop in water pressure from someone flushing a toilet or a washing machine. I would call the company to remedy this issue.

17. What is a cold water sandwich effect? The term “cold water sandwich effect” is a term that is used to describe the introduction of cold water into the hot water supply line during frequent on/off operation of an instantaneous water heater. The cold water sandwich effect, when present, appears as a momentary drop in hot water temperature as it is discharged from a hot water supply outlet (i.e. shower, tub, or faucet). This phenomenon is present in the operation of all instantaneous, tankless style, water heaters, but is minimized with the high tech design of Rinnai water heaters.
The technology built into the Rinnai water heaters is designed to minimize the cold water sandwich effect. Rinnai water heaters are microprocessor controlled and when water flow through them ceases, they remain in a “ready to fire state” for approximately 1 minute. If water flow through a Rinnai water heater begins within the first minute following water flow stoppage, the water heater will fire back up within 1 to 2 seconds. This minimizes the cold water sandwich effect that would otherwise be experienced with a low tech tankless water heater. It should be noted that the cold water sandwich effect cannot be removed completely from tankless style water heaters. The safety standards developed to insure the safe operation of water heaters require a delay in the ignition sequence of all gas water heaters.
While the cold water sandwich effect cannot be completely eliminated from standard plumbing systems, it can be eliminated from plumbing systems that have a supply and return hot water circulating system. Rinnai has developed 2 methods to eliminate the cold water sandwich effect in residential hot water circulating systems.
The first (and preferred) method to remove the cold water sandwich from circulating systems utilizes a small electric tank water heater (powered up) that is used with a dual purpose. The small water heater acts as a mixing tank to eliminate the cold water sandwich effect from the Rinnai water heater and it uses its electric heating element to offset the heat losses from the hot water circulating system.
The second method to remove the cold water sandwich from circulating systems utilizes a small 2 to 6 gallon storage tank installed on the hot water outlet of the Rinnai water heater. This tank acts as a mixing tank to blend the cold water sandwich with hot water and eliminating its effect at fixtures.

Mar 11, 2009 | Rinnai Water Heaters

1 Answer

Sandwich bar


I had a similar problem, & found out that what was making the noise is the cardboard siding on the condensor(bottom of the cooler) I placed a "shim" between the cardboar and that took care of the noise.

Mar 29, 2008 | True Refrigerators

1 Answer

True Freezer Running Too Cold


thermostat is stuck closed, if not compressor relay is stuck closed, if not then the defrost timer is stuck closed. test the components in that order.

Mar 22, 2008 | True 12 cu. ft. / 340 liter Commercial...

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

50 people viewed this question

Ask a Question

Usually answered in minutes!

Top True Refrigerators Experts

Dennis Boxerman

Level 3 Expert

1035 Answers

John Tripp
John Tripp

Level 3 Expert

4654 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Are you a True Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...