Question about Konica Minolta bizhub Office Equipment & Supplies

1 Answer

Bizhub 185 c2558 Error how to clean - bizhub Konica Minolta Office Equipment & Supplies

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    New Friend:

    An expert that has 1 follower.

    Cheetah:

    An expert who has answered 20 or more questions within one hour.

  • Expert
  • 79 Answers

Abnormal High Toner ration in developer.

Replace With new developer DV-116 , and use good quality toner.

Posted on Dec 25, 2016

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Bizhub c224e error code 2558


Konica-Minolta bizhub C224e Code: C2558

Description

Abnormally high toner density detected black TCR sensor
The TC ratio of the toner determined by the toner replenishment control is detected to be the predetermined value or over for consecutive times.

Remedy

1 Reinstall developing unit. 2 Reinstall toner cartridge. 3 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16, CN10 for proper connection and correct as necessary. 4 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary. 5 Replace the developing unit. 6 Replace FRB. 7 Replace PRCB.

http://www.printcopy.info/?l=en&mod=erc&brand=Konica-Minolta&model=bizhub%20C224e&code=C2558

Aug 22, 2016 | Konica Minolta bizhub Office Equipment &...

3 Answers

Konica minolta bizhub 215 giving error c2558


C2558
Abnormally high toner density detected TCR sensor board
- The T/C ratios detected by the TCR sensor board (TCRSB) are above the threshold for the detection of abnormally high T/C ratio for three successive times.
- The connector between MFPB to TCRSB is disconnected.

Error Codes Konica Minolta bizhub 215

Mar 07, 2015 | Konica Minolta Office Equipment & Supplies

1 Answer

Error code c2558 in konica Minolta bizhub 164


help me my konico minolta bizhub 184/164 error (C2558) my mail id ganaa_et24@yahoo.com

Sep 30, 2013 | Office Equipment & Supplies

1 Answer

How to solve konica minilta c224 machine c2558 error


SHAKE THE BLACK IU VERY WELL Clean Imaging Unit Contacts RUN GRADATION
UPDATE FIRMWARE
REPLACE BLACK IU

Jun 29, 2013 | Konica Minolta Bizhub C224 Color Copier...

1 Answer

Error code c2558 for konika bizhub 215


I have solution for this problem now. I tried alot to sought out this C2558 error in bizhub 215 & 195 but i got failed. But now i have a solution for this error after wasting my 2 days & searching data, youtube, website, manual, installation guide & more. Here is solution for this C2558 Error in Konica Minolta Bizhub 215 & 195 :- Step-1. You need to change your developer(a packet pouch of developer), if you have not done yet. if you have already changed your developer then jump to step2. (Note - for installing & refilling devloper into the cartridge check other guide on youtube for how to re-fill developer. Step-2. Be Carful there should be no Toner bottle. Don't get confused with tonner bottle & developer both are different. so remove tonner bottel from machine. Step-3. switch Off & re - switch on the machine . Step-4. when machine finish warming after that - Press UTILITY (tool) button. Then Enter service mode by pressing the buttons [Stop], [0] [0], [Stop], [0] [1]. (Note you should press this sequence in continous). The display shows the service mode.On the menu SERVICE WITH chioce press [OK].Use the buttons next to the display and select menu FUNCTION. Step-5. Press [OK]. Step-6. Use the buttons next to the display and select the menu AUTO ADJUST TCR. Step-7. Press [OK] and set ATDC. For about 2 min. the following message appears: TCR TCR AUTO ADJUST GAIN: ### where ### is the number Step-8. Turn the machine off the main switch. (finished if there is no error message , you can check print without tonner bottel. after that if there is no error message of c2258 then you can put bottle inside) If the machine displays an error message C2557 or C2558, check whether you have correctly connected terminal, which is detached when removing the developer. Installing the toner bottle :- Step-1. Before using the toner Shake the toner bottle. Step-2. Open the front door. Step3. Insert the toner bottle into about halfway with the label (Tape) on top of the toner bottle, and then slowly Just remove the label from the toner bottle. Step-4. Align the toner bottle to mark the arrow and push the bottle to the far end of the toner bottle. -----GOOD LUCK-----

Jan 15, 2013 | Konica Minolta bizhub C450P Laser Printer

1 Answer

CARA RESET M2 BIZHUB 164


bagaimana cara reset bizhub 164 error c2558 mohon penjelasannya

Jun 28, 2012 | Office Equipment & Supplies

1 Answer

Konical minolta bizhub 164 mahine service call c2558


machine trouble sevice call [c2558] wat a problam in konica minolta bizhub 164 printer

Jun 02, 2012 | Konica Minolta bizhub C250 All-In-One...

1 Answer

Minolta bizhub 164 error code C2558..how can I solve


I have solution for this problem now. I tried alot to sought out this C2558 error in bizhub 215 & 195 but i got failed. But now i have a solution for this error after wasting my 2 days & searching data, youtube, website, manual, installation guide & more. Here is solution for this C2558 Error in Konica Minolta Bizhub 215 & 195 :-

Step-1. You need to change your developer(a packet pouch of developer), if you have not done yet. if you have already changed your developer then jump to step2. (Note - for installing & refilling devloper into the cartridge check other guide on youtube for how to re-fill developer.

Step-2. Be Carful there should be no Toner bottle. Don't get confused with tonner bottle & developer both are different. so remove tonner bottel from machine.

Step-3. switch Off & re - switch on the machine .

Step-4. when machine finish warming after that - Press UTILITY (tool) button. Then Enter service mode by pressing the buttons [Stop], [0] [0], [Stop], [0] [1]. (Note you should press this sequence in continous). The display shows the service mode.On the menu SERVICE WITH chioce press [OK].Use the buttons next to the display and select menu FUNCTION.

Step-5. Press [OK].

Step-6. Use the buttons next to the display and select the menu AUTO ADJUST TCR.

Step-7. Press [OK] and set ATDC. For about 2 min. the following message appears: TCR TCR AUTO ADJUST GAIN: ### where ### is the number

Step-8. Turn the machine off the main switch.

THATS IT - YOU ARE DONE - FINISHED

DONE - ERROR REMOVED

(finished if there is no error message , you can check print without tonner bottel. after that if there is no error message of c2258 then you can put bottle inside)

If the machine displays an error message C2557 or C2558, check whether you have correctly connected terminal, which is detached when removing the developer.


Installing the toner bottle :-

Step-1. Before using the toner Shake the toner bottle.

Step-2. Open the front door.

Step3. Insert the toner bottle into about halfway with the label (Tape) on top of the toner bottle, and then slowly Just remove the label from the toner bottle.

Step-4. Align the toner bottle to mark the arrow and push the bottle to the far end of the toner bottle.
-----GOOD LUCK-----

Mar 06, 2012 | Office Equipment & Supplies

2 Answers

What is a service code c2558 mean on my copier?


C2558: Abnormally high toner density detected black TCR sensor
Reinstall imaging unit
Reinstall toner cartridge
Change imaging unit/K
Change PRCB

Sep 28, 2010 | Konica Minolta Bizhub c203 Copier

5 Answers

How do I clear error message C-2558 for the Konica Minolta bizhub C253


tis error means abnormal tonder density in the balck image unit take the blacke image unit out and shake it while holding it level and put it back in the machine to reset the error code leave the machine on and open then close the front door

Nov 12, 2009 | Konica Minolta bizhub C250 All-In-One...

Not finding what you are looking for?
Office Equipment & Supplies Logo

Related Topics:

225 people viewed this question

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman  J Weimar Jr
Norman J Weimar Jr

Level 3 Expert

6161 Answers

Ben
Ben

Level 2 Expert

108 Answers

David Burkhart
David Burkhart

Level 2 Expert

210 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...