Question about Rinnai Desa Vent-Free Infrared Gas Heater: Vent-Free Infrared Gas Heater(18,000 BTU)

3 Answers

Glo-Warm Wall Gas Wall-heater parts...

Hi! I own a Glo-Warm "Blue-Flame" Natural Gas Wall Heater... I need a {new control knob} & {ignitor switch}...The control knob won't release the pilot switch when lit, to ignite the blue flame from pilot to make it slide to low heat???...
The problem is, I can't find what I need on your web-site search ?
My Glo-Warm says it's a SIT 630 Eurosit #0630 & the Model number is: 0630-545 ??
There's also a few other numbers too that are: #9945 & #1921906, #3008 ??? I have no idea what they mean ?
Can you help me out with this order ?
Best regards, Mike...

Posted by on

  • 1 more comment 
  • ntrdmfn Dec 02, 2007

    Pilot light will light when I hold the knob down in pilot light position but as soon as I release the knob the pilot light goes out. I have cleaned the heater thoroughly.

  • Anonymous Jan 03, 2008

    Switched the thermostat to a different heater.

  • joeymollo
    joeymollo May 07, 2013

    Replaced thermocouple. Pilot stil won't stay lit



3 Answers

  • Level 1:

    An expert who has achieved level 1.


    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

We had a problem keeping the pilot light to stay on, and this site recommended that it could possibly be the thermocoupler that was causing our problems also. We ordered the thermocouple, put it on,hooked it back up and it worked great! Thank you so much.
ordered thermocouple from

Posted on Feb 24, 2009

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points


    An expert that got 10 achievements.


    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 625 Answers

Try this site. I don't know what numbers will work but they have parts for dyna glo.

Posted on Dec 09, 2007

  • Level 1:

    An expert who has achieved level 1.

    New Friend:

    An expert that has 1 follower.

  • Contributor
  • 4 Answers

Thanks for the info... I had the same problem. I have a RMC-LC10LPT indoor propane heater and the pilot light wouldn't stay lit. The part number for the thermocouple is on the old part bracket. My part # is LPG8420 and the part that replaces it is 104286-01.

Posted on Apr 02, 2013

1 Suggested Answer

  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%


Complete. Click "Add" to insert your video. Add



Related Questions:

2 Answers

Glo warm heater

the regulator IS not only the issue, but it's a major safety benefit,..the pilot flame is non adunstable..get a cheap regulator(like the ones for the outdoor bbq's)

Mar 16, 2008 | Heating & Cooling

1 Answer

I have a dyna glo RMC 40 NGT vent less wall heater that I would like to convert to propane, I need to know which conversion kit to buy, and where. Thank you.

dyna glo natural gas heater Questions & Answers - Fixya > Forum > Tags
dyna glo ventless rmc50 ngt can this heater be changed from natural gas to propaneuse, ... Dyna Glo Natural Gas conversion to LP Gas I have a Dyna-Glo natural gas space ... Question about D-E36 Infra-Red Wall Mounted Panel Heater ... dyna glo heater model #RMC-40GT I believe on your particular model , that you ...

Parts for Dyna Glo, Thermoheat and Dyna Glo Pro Heaters
Shop Dyna Glo, Thermoheat, Dura Heat, Workhorse LP and oil fired htrs ... Circuit Board 2201181 Dyna Glo & Thermoheat 150k Nat Gas Htr RMC-FA150NGDGD ... This spark plug (ignitor) is used on Dyna Glo and Thermoheat 40K btu LP.

Propane Wall Heaters - > ... > Heaters

WalmartDyna-Glo IR18NMDG-1 18,000 BTU Natural Gas - Infrared Vent Free Wall Heater. $170. ... Dyna-Glo 40K Liquid Propane 360-Degree Tank Top Heater. $88.00 ... Dyna-Glo Deluxe RMC-FA125DGD Portable Gas Powered Forced Air Heater.

1352062 Dyna Glo Natural Gas conversion to LP Gas

Jan 12, 2016 | Heating & Cooling

1 Answer

New blue flame heater, everything is hooked up, gas is going to unit, I have a natural gas hookup, in the correct port, knob is turned and locked into the NG position but unit wont light. There is gas...

do you have the pilot light burning if not then you have to get in burning first
Put knob in pilot position push down and hold for at least 30 seconds or longer then if there is an igniter push and release it push and release till pilot light comes on .Continue to hold pilot light button down for another 10 seconds or so, release pilot button and turn button to on or up a number or set T stat
Main flame should come on and burn

Oct 13, 2013 | Procom Heating & Cooling

1 Answer

Jandy LG250N pilot won't stay on after releasing switch on gas valve. Main switch on unit is off. I am able to keep pilot flame on for one minute by depressing switch but pilot always goes out after...

Thank you for posting your question here on

No, the pilot generator or the pilot head itself is the issue. You need a good, solid blue flame across the generator to get enough power to hold the switch open when you let go of the knob. If the pilot flame is week or not aimed across the generator it will not stay lit.

If it is but the generator is old and weak, it will go out as well. If you can see the pilot flame and it is a nice blue color, replace the generator. If it is not, disassemble the pilot and either clean it out or replace it.

If this answer does not fix your problem, please comment with additional details prior to rating the answer. You may also contact me thru our website at Positive feedback is appreciated once your problem is solved!


Aug 06, 2011 | Jandy Lite 2 Natural Gas Pilot Light...

1 Answer


can you turn flames down with the control knob ,if not you need control gas valve,that if burning right gas for heater you got. Check the data plate.If not right gas your heater your living very dangerous.

Jan 22, 2011 | Vanguard International Blue Flame - Large...

1 Answer

Can I convert my natural gas glo-warm wall heater to propane?

Converting gas appliances normally entails the replacement of a jet that controls the flow of gas and in most cases, the manufacturer will (or will not) have replacement jets available. If they do, it should not be costly or difficult since they are often only screwed on.

May 14, 2010 | Desa International Blower Glow Warm Wall...

1 Answer

How do i adjust the flame on ,my glo-warm propane heater?

if there is any adjustment it will be on the gas valve itself under the front of the unit....should have a little door that pulls should see a knob that says "Higher....Lower" something like that....if the knob only says "ON , Off and Pilot" there is no adjustment

Oct 19, 2009 | Dyna-Glo D-E37 Wall Mounted Panel Heater

1 Answer

Pilotlight will not light, getting spark, but no propane.

make sure you have the gas valve knob on turned to pilot while pressing that down while pushing the spark it should light or it is tripped on a safety like rollout switch or oxygen depletion sensor if equipped which all ventless heaters are

May 12, 2009 | Dyna-Glo D-E37 Wall Mounted Panel Heater

Not finding what you are looking for?
Heating & Cooling Logo

6,926 people viewed this question

Ask a Question

Usually answered in minutes!

Top Rinnai Heating & Cooling Experts

Paul Carew

Level 3 Expert

3150 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

vance jones

Level 2 Expert

120 Answers

Are you a Rinnai Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides