FPSH series is a power vented residential gas water heater.
1) The blower is plugged into 120Volt outlet. If blower has short, then it will trip breaker.
Blower could be Fasco model 7021-10195, or 7021-10770. Call AO Smith: 1-800-527-1953. They will need model number and serial number located on label on side of tank.
2) Before calling AO Smith, check outlet with circuit analyzer. Outlet must have correct polarity and must be grounded. Unplug cord to water heater and run continuity test from ground prong on electrical plug to manifold tube on gas valve.
3) Also if a fluorescent light fixture is on the same breaker, that can cause burner to short cycle.
4) Connect water heater to different outlet and see if problem continues.
5) AO SmIth has service manuals for the FPSH series that download to your computer:
http://www.hotwater.com/resources/product-literature/service-handbooks/
×