Question about Standard (CRT) Televisions

1 Answer

How to take the back off the TV?

I have a big Sony that blinks 6 times..etc. I've been on enough forums to see that I can remove the D board...bla bla bla.......& there are several options for repair (send it off...or buy IC's off of ebay and fix myself.... I'm an engineer and can fix about anything).
I'm would like to start off right and don't see an obvious way to get the back off the TV except to start removing all the screws, etc.
How should this be done...should I lay the TV forward on it's screen?
Any advice would be helpful.

Posted by on

1 Answer

Re: How to take the back off the TV?

Yes you can take the back off and could probably do your tv a favour by blowing(carefully) the two inch layer of dust that sony tv's tend to gather,(if done regularly, it would stop these problems from happening in the first place)..... dont take the back off till you have allowed a 12 hour discharge period(thats unplugged) and if your an engineer then you can follow the screws that apply to the back and go over the top of the inlets.... then just tilt it forward when your ready to pull it off..... happy fixing....

Posted on Sep 22, 2008

Add Your Answer

0 characters

Uploading: 0%


Complete. Click "Add" to insert your video. Add


3 Points

Related Questions:

1 Answer

My television will not turn on. The light blinks 6 times over and over again and there is no picture or audio.

that chassis for sony is the DA4 chassis and they had a big problem with regulator failures in the main power supply. primary and secondary power regulators the location numbers are IC8002 and IC6501 i believe the part number from sony is MCZ3001DB you must get the part number that ends is (DB) or you will not reliably repair the tv. the sony part number is 6-705-810-01 they are going to cost around $20 each because they are the good parts. they are going to be about 20 pin ICs and you will just need to desolder old ones and resolder new. they will be on the board on the left looking from the back about middle of the board on the left hand side. good luck!!!

Jan 26, 2011 | Sony FD Trinitron WEGA KV-36HS510 36" TV

1 Answer

Will only turn on for about 3 second with no picture and then turns off. Standby light blinks 6 times

For the KV30HS420, 6 blinks, pause, 6 blinks, etc. means "LOW +B OCP/OVP (overcurrent/overvoltage)" and the probable cause locations listed are as follows:

1. +5 line is overloaded (A, B, M boards)
2. +5 line is shorted (A, B, M boards)
3. IC504 is faulty (A board)

hope this helps John

Jan 11, 2011 | Sony FD Trinitron WEGA KV-30HS420 30" TV

3 Answers

Sony Trinitron TV

read the answer on this page really helpfull

Apr 01, 2010 | Sony FD Trinitron WEGA KV-27FV17 27" TV

1 Answer

Light blinks 6 times, no picture, no sound

6 times blinks shows error of Low +B, OVP/ OCP
Replace IC6501 & IC8002 [ MCZ3001D ] on D board.
If you are handy with electronics stuff repair and can solder parts in circuit board then replace above said ICs or call local TV tech to do the job.

Sep 22, 2009 | Sony FD Trinitron WEGA KV-32FS120 32" TV

1 Answer

Exact same model, went out on the exact same date

sony blink code 6 blinks means that your tv has no horizontal,no rasta check c515 and 516 and the jungle ic IC 206,SEVEN BLINKS MEANS,high voltage shutdown,hig voltage exceed 33k and the set go in safety shutdown,check power supply regulation and horizontal circuits.if you are not a tech have one check and repair your set.

Jul 12, 2009 | Sony FD Trinitron WEGA KV-34HS420 34" TV

1 Answer

My TV (Sony Bravia LCD KLV-32S310A) goes of after 20 seconds when it is switched on. The standby indicator then flashes (red) six (6) times then there is a two seconds break followed by another six flashes...

6 times blink shows problem with back light inverter board.
TV requires back light inverter board replacement. If you have electronics repair experience and want to repair TV by yourself, let me know to guide you part purchase.

Apr 13, 2009 | Sony KV-35S42 35" TV

1 Answer

Sony FD Trinitron WEGA KV-34HS510 ... does not power up.

  • 6 times, Diagnosis: LOW B OCP/OVP (Overcurrent/over voltage). Possible causes: +5 line is overloaded. (A, B boards), +5 line is shorted. (A, B boards). Symptoms of the problem: No picture.This may help the solution or let no what is wrong!!
  • Jan 16, 2009 | Sony FD Trinitron WEGA KV-34HS510 34" TV

    1 Answer

    I have a sony 51 " rptv. the on screen image arcs on top and bottom towards the middle of the screen he sel diagnostics showed 1 timw akb and 1 hv. the timer blight has been blinking 4 times then stops any...

    4 times blink is error code for Vertical Deflection problem and you need to check +15 and -15 volt supplies on D board and IC8003 is suspected.
    Needless to say, check above in case you have enough knowledge and experience of big TV repair as high voltage shock risk is involved.
    Thank you.

    Dec 14, 2008 | Sony KP-46S25 TV

    1 Answer


    check for short HOT on the A board or IC1751 on the C board. if you do not know much about electronics please have someone qualified repair this, for your own safety. there are voltages in this set that can hurt you. 33,000 volts

    Jan 18, 2008 | Sony KV-36FS100 36" TV

    Not finding what you are looking for?
    Standard (CRT) Televisions Logo

    Related Topics:

    89 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top Standard (CRT) Televisions Experts

    The Knight
    The Knight

    Level 3 Expert

    66409 Answers

    matt martin
    matt martin

    Level 3 Expert

    1187 Answers

    Donald DCruz
    Donald DCruz

    Level 3 Expert

    17129 Answers

    Are you a Standard (CRT) Television Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides