Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one.

Posted by on

2 Answers

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer
Re: Amana PTAC


Posted on Nov 27, 2007

  • Level 1:

    An expert who has achieved level 1.


    An expert that gotĀ 5 achievements.


    An expert whose answer gotĀ voted for 20 times.


    An expert who has answered 20 questions.

  • Contributor
  • 49 Answers
Re: Amana PTAC

Sounds like if this is a heat pump, maybe it tripped out on high pressure. Maybe just unplugging the system may reset the control boards. This maybe due to a dirty filter or dirty evaporator coil.

Posted on Nov 18, 2007

Add Your Answer

0 characters

Uploading: 0%


Complete. Click "Add" to insert your video. Add


3 Points

Related Questions:

1 Answer

My amana ptac is not heating....the code "np" is do I correct this...we just installed the unit and know little about operation. Thanks

I don't see this error code in the manual. I do see nP as an error code for Window Switch lockout. I just had this happen to me and they had me reset the control board.

Remove case, flick master switch to OFF for 10 seconds. Press Heat/Cool same time turn switch back on HOLD until off light comes on.

You should be fixed. Just had to do this for my unit. I was playing around with the settings and turned on the window switch option by accident.

Feb 02, 2013 | Amana In Wall Install Kit For Digismart...

3 Answers

I have an Amana ptac hotel type thru the wall unit. The unit won't turn on - it's plugged in. The gfi button is popped out. There is power to the wall plug. Any ideas?

If you reset the GFCI button and then when you go to turn it on the button pops again, then you have a short inside the units probably in the fan motor or the compressor..


May 14, 2011 | Amana PTH123B25AJ Heat Pump Air...

1 Answer

I have an Amana PTAC unit model no. PTH153B50AM. It will not heat, but the fan runs continuously in the heat mode. The unit has a label that says it has a manual reset for the heater, but no direction as...

First unplug the unit......Take the front cover off, take the wire screen off where the front fan is there is 4 or 5 screws that hold the plate that was under the screen. The electric heating elements are under that plate between the evaporator coil and the front blower wheel. It will lift straight up and give you access to the elements. In the electric heating element area there is a limit switch with a red or black button in the center of it push it to reset the limit it is on the right hand side by the controls. I wish I could find a picture to show you but I couldn't find one. It is not easy to get to... Hope this helps.

Feb 12, 2011 | Amana PTH153B50AM Air Conditioner

1 Answer

I have a AMANA PTh153B50AE (PTAC unit). The air conditioner works fine. It is when I turn on my heater and it does not get warm. It just blows cold air. I have looked at the board and it appears that...

I have the same problem, and I found the manual reset inside the unit. Turn the power off, and unplug the unit. Remove the outer cover of the unit ( inside cover ) , and remove the 2 screws holding the " wire mesh " in the front of the cover. Pull the wire mesh up and out of the way, then carefully pull out the heating element.
On the heating element, where the wires are connected, there is a manual reset button... Push the button in, till it resets...

My reset was on the upper left connection of the wires... just looks like a small push button, but the reset is recessed a bit.
Replace all covers and plug back in.. working fine..

Nov 12, 2010 | Amana PTH153B50AE Air Conditioner

1 Answer

Amana PTAC PTC093A35AA won't blow heat

The reset button is located behing a panel on the front of the unit that is labeled Heat Reset. If that label is gone then look around, it is a small hole, small enough for a paper clip to fit through.
That being said, I have 137 of these units in one of my hotels and have not had a single one needing to be reset. You probably are going to need a new control board kit. These can be purchased from Amana. They are $130. Make sure that you have pulled the heater coil out and inspected it first. Also, there was a recall years ago where Amana was supposed to contact and send out new voltage switches. These are the round black things that the Brown heater wires connect to on the upper and lower side of the heating coil. You should also try to replace those if you find the coil in good condition. I have had those resolve heating issues. Most of the heating issues were a result of a bad relay on the control board though.
Please remember to rate this fix.

Jan 23, 2009 | GE Zoneline AZ38H12DAD Split System Air...

5 Answers

Amana PTAC

I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you set on the control panel is within 2-1/4 degrees (or 4 degrees depending on your unit model. Otherwise, the unit locks out the compressor until the electric heat coil bring the indoor temperature up to that level - and then will switch the compressor back on for heat pump operation. So the problem is not the control panel or the compressor, it the electric heat coil. The coil has two manual limit switches on it that may be tripped and should be checked. The coil can be easily accessed by shutting down the power, removing 4 screws around the air outlet, pushing the screen up and sliding the panel out the top. The power wires can remain in place while the limit switches are reset. Hope it works.

Nov 02, 2008 | Amana PTH123B25AJ Heat Pump Air...

1 Answer

Charging a ptac

Either or, they both are the same ends but different routes..

Sep 08, 2008 | Amana PTH123B25AJ Heat Pump Air...

3 Answers

Amana ac/heating unit model PGD60C1152E

I need more info. Is this a split system, packaged, or ptac. Heat pump or electric heat strip?

Nov 18, 2007 | Amana Haier AP125HD Air Conditioner

3 Answers

Ptac fan keeps blowing

Try setting the fan control to "AUTO" this will cause it to cut out with the compressor.

May 02, 2007 | Amana PTH123B25AJ Heat Pump Air...

Not finding what you are looking for?
Amana PTH123B25AJ Heat Pump Air Conditioner Logo

629 people viewed this question

Ask a Question

Usually answered in minutes!

Top Amana Air Conditioners Experts


Level 2 Expert

55 Answers

D. E. Hev

Level 3 Expert

1059 Answers


Level 3 Expert

2963 Answers

Are you an Amana Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides