SC364
Description: TD sensor error black PCU
possible cause:
• TD sensor harness disconnected, loose, defective
• A drawer connector (located on the rear of a development unit) disconnected, loose, defective
• TD sensor defective, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD sensor is defective