Generac 400oexl model 01645 generator, runs fine, no voltage

It starts and run fine but no voltage and the low idle dosn`t work anymore. Where should I start to look for problems, no manuals I can find have diagnosing procedures

Posted by on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
CarlGehrke
  • 169 Answers

SOURCE: Generac Guardian 17.5KW Generator dies

If this is one of the big "taco cart" portables you need to check that the vent on the gas cap is open when you're running the engine. In the center of the gage on the gas cap is a little knurled knob, turn it counter clockwise (lefty loosey), about a half turn or so and run the generator.
If that doesn't solve your problem add to it here, otherwise please give me a rating I'm trying to build a little credibility here and could use the help.
Carl

Posted on Dec 02, 2008

Ad
mydogisk
  • 50 Answers

SOURCE: Guardian generac 10kw model 5502 does not output correct voltage

the instructions says the voltage regulator is automatic/digital. when you check the voltage is there any load on the generator? if applying load to the generator doesn't help, you can manually change the motor speed where the governor connects to the carborator, but it may change the frequency, but the regulator may fix it

Posted on Apr 13, 2009

mamicheddy
  • 79 Answers

SOURCE: no electrical output

It is possible that your voltage regulator is shot but before purchasing the volt regulator try flashing the fields first and make sure the brushes and rings are clean.

Posted on May 12, 2009

  • 17 Answers

SOURCE: Can't find manual for generac mega force generator

plain 30 wt is fine.

Posted on Jun 28, 2009

sal_kh_sab
  • 98 Answers

SOURCE: ust 3000 generator-only idles-no voltage output

chek brushes...if they seemed ok then replace AVR card

Posted on Oct 11, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I need a rectifier or avr for generac 3500 xl genarator


Ebay and various places including the maker..

  • VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR-GENERATORS ... www.ebay.com/sch/sis.html?_nkw=VOLTAGE-REGULATOR-3000-3500-WATT... VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR ... New listing 3500 Watt Generator AVR Automatic ... 3500W Generator AVR Automatic Voltage Rectifier ...
  • 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator ... https://sites.google.com/site/kltthtyz0i04cd/3500-w-3500-watt... Generac Guardian 22kW Standby Generator NG ... Previously Pay for Shop 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator Rectifier 3.5KW Generator AVR ...
  • How to test your Electricity Generator's AVR, Brushes and ... www.youtube.com/watch?v=tC_LrrZcx38
    • BY GENERATOR GURU
    • 9 MIN
    • 454K VIEWS
    2011-10-21 · Video embedded · When your electricity Generator stops producing power, ... How to test your Electricity Generator's AVR, ... Generac iQ: The Quietest Generator ...
  • Generac Power Systems - Home www.generac.com Generac manufactures the widest range of power products in the marketplace including portable, RV, residential, commercial and industrial generators.
  • Generac Guardian Generator Voltage Regulator Rectifier ... www.ebay.com/sch/sis.html?_nkw=Generac+Guardian+Generator+Voltage... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator ...
  • Automatic Voltage Regulator (AVR) for Generators portable.generatorguide.net/avr.html How automatic voltage regulator (AVR) works in portable generators: ... here you can see a reverse engineered Generac regulator that uses SCRs and UJT.
  • Diagnosing A Generator That Has No Power Output. - YouTube Youtube
    • BY THEDIYGUYDOTNET
    • 3 MIN
    • 150K VIEWS
    2012-11-12 · Video embedded · Diagnosing A Generator That Has No Power Output. ... How to test your Electricity Generator's AVR, ... Generac Portable Generator ...
  • GENERATOR Diagram & Parts List for Model 3500xl Generac ... www.searspartsdirect.com > ... > 3500XL GENERAC Generator-Parts GENERATOR Diagram and Parts List for GENERAC Generator-Parts model # 3500XL ... Generator rectifier Part #: ... Generator voltage regulator Part #: ...


  • Jun 28, 2016 | Generac Electrical Supplies

    1 Answer

    Generac troubleshooting


    please send me more info about this generator I need a model number is this a natural gas or propane I have a neighbor that just had one installed I might be able to get some info from him to help you

    Aug 30, 2014 | Generac 17 Kw Air-Cooled Standby Generator...

    1 Answer

    Low voltage out 79.2 volts


    Randy, connect up your volt meter and try manually reving up the engine. Even a few hundred RPM can make a big difference in the generator output.

    If that resolves the problem, then you need to adjust the high speed settings on the motor.

    Mar 03, 2014 | Electrical Supplies

    1 Answer

    Generac portable generator over voltage even with new control board and regulator


    is engine running at 3600 to 3700 rpm at full load. most small engines run at this speed.you can buy a small tach on ebay TINY TACH.. you have to know what the engine speed is

    Mar 04, 2013 | Electrical Supplies

    1 Answer

    Need Users manual for Generac 4000 EXL generator


    Hi and welcome to FixYa, I am Kelly
    Below is a list of all the manuals an owner should have:

    For the 4000 EXL Your actual model number is 01645.
    Operators manual:
    http://www.generac-portables.com/document/index.cfm?doc=1645_0EN11CS_LO.pdf

    Wiring Diagram:
    http://www.generac-portables.com/document/index.cfm?doc=1645_0WDS_LO.pdf


    Parts List:
    http://www.generac-portables.com/document/index.cfm?doc=1645_0PARTSLISTCCS_LO.pdf

    Thanks for choosing FixYa,
    Kelly

    May 18, 2011 | Garden

    1 Answer

    Generac 4000xl high idle, idle control not working.


    check to see if somthing is blocking the movement of the govenor linkage

    Oct 26, 2009 | Electrical Supplies

    2 Answers

    20KW Guardian Generac does not produce 12 volts to run engine


    The problem is that the printed circuit board inside the generator draws a little current from the battery even when the generator is not running. Over the course of a few days this can make the battery weak enough to be unable to get recharged by the built in running charger which results in not enough power to run the electronic governor on the generator. Usually the spark plugs will work even with a fairly low battery.

    Most of the Generac generators come with a built in trickle charger that runs off of the transfer switch load terminals. If your built in charger isn't doing the job it's either broken or you have the wrong sort of battery installed in the generator.

    Regards,
    Carl

    Jan 11, 2009 | Electrical Supplies

    Not finding what you are looking for?
    Generac Guardian 065795 -  battery charger rectifier Logo

    Related Topics:

    809 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top Generac Guardian Electrical Supplies Experts

    jdthefixer

    Level 3 Expert

    744 Answers

    yadayada
    yadayada

    Level 3 Expert

    76164 Answers

    epangan29

    Level 2 Expert

    112 Answers

    Are you a Generac Guardian Electrical Supply Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides

    Loading...