Warning and standby indicator of JVC D-ILA Projector model DLA-X70RBE flashing simultaneously.

The warning and standby indicator lights are flashing simultaneously. The warning indicator flashes twice and the standby indicator flashes once. I have already unplugged the power cord for longer than an hour to reset the projector. There is nothing blocking the air vents and filters are clean.

Posted by on

Ad

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • JVC Master
  • 11,573 Answers

Johan, Below are links to your model where you can access,manual,instructions and get support.
Press the helpful button and follow me on fixya for more tips and info.

4K shift ILA Projector DLA X70R Introduction

Replacing lamp on JVC Series Projectors



JVC DLA X3 Warning light issues

Posted on Feb 11, 2016

Ad
  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Master:

    An expert who has achieved Level 3.

  • Master
  • 206 Answers

I don't see your model number on JVC's website
this is the closest model I found which has a LCD display. Does yours have a display and can you verify the model number is correct.
This is the closest to your model number I could find.
shift3 ILA Projector DLA X700R Overview
usually this indicates you need to replace your lamp.

could also be the sensor that makes sure the lamp is properly installed.
Replacement Lamp for ILA Projectors PK L2312UG Features 4K

Posted on Feb 11, 2016

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have JVC D-ILA projector and we just had thunderstorm and now it won't come back on


I had the same trouble with telephone answering machines - every thunderstorm and I would need a new one...

Lightning strikes and near misses and power outages can create mains borne voltage spikes and surges that frequently damage sensitive electronics. These days almost everything is a computer or contains a computer that uses extremely sensitive CMOS chips.

Electronics manufacturers don't make things better than they need to be for obvious reasons and so it is up to the user to protect appliances from damaging surges by using the most expensive of these with a surge protector and by using an area protector.

Since the penny dropped and I invested in a surge protector I haven't needed to replace my answering machine...

Aug 26, 2016 | JVC DLA-RS4800U Projector DLA-RS4800U

1 Answer

The indicator of temperature is red, the indicator of the bulb is off and the fan after 3 o 5 minutes


PowerLite 7800p Multimedia Projector - Epson

www.epson.com/cgi-bin/Store/support/supDetail.jsp?...oid...

EpsonPowerLite 7800p Multimedia Projector. Support ... Indicator Light, Status, Description... Temperature, Red, The projector is overheating, which turns the lamp off ...

PowerLite 735c Multimedia Projector - Epson

www.epson.com/cgi-bin/Store/support/supDetail.jsp?...oid...

EpsonPowerLite 735c Multimedia Projector ... Indicator Light, Status, Description ...Lamp/Temperature, Red, The projector is overheating, which turns the lamp off ...

Maintenance Indicators - ManualsLib

www.manualslib.com > ... > Notevision PG-F212X > Operation manual
The warning lights (power indicator, lamp indicator and temperature warning... ... Redon. Normal (Standby). Green on. Normal (Power on). Red blinks. Abnormal ... Sharpmultimedia projector model xg-mb67x-l operation manual (71 pages).

Dec 14, 2015 | Office Equipment & Supplies

1 Answer

How to re-programme new car batteries in car key ?


1. Turn the ignition switch from Position 0 to ON 6 times within 10 seconds.
2. Then turn ignition switch to OFF position. Leave key in ignition switch.
3. After 2 seconds, the system will enter programming mode and will flash the warning lights twice.
4. Press and HOLD the unlock button on the Plip.
5. While pressing the unlock button, press the lock button 3 times.
6. Release the unlock button.
7. The warning lights will flash once to indicate successful programming.
8. Repeat procedure 4 to 7 for up to 4 plip key's.
9. When completed turn ignition ON, and the warning lights will flash 2 times.
10. Remove key, and check all plip key's for operation.
NOTE : The programming mode will stop when either the ignition is switch ON, 4 plip keys have been programmed or no input signal either from the switch or plip keys has been received for 120 seconds.

Nov 08, 2014 | Cars & Trucks

1 Answer

Jvc x3 projector orange lamp light flashes wont power up


1,Check the fans ,if the fan is running
2,Inductor (Sensing element),near the Color Wheel. Use a cotton swab moistened with alcohol to wipe the Inductor.
Have a good day!
We supply original projector parts: lamp, bulb, Lcd, Lens, DMD,
motherboard, powersupply ... with high quality and competitive price.
Jerry China
Tel: +86 131788 67858
E-mail: lampdeng@hotmail.com
Skype: lampdeng.com
YM: lampdeng@yahoo.com
http://facebook.com/lampdeng
http://www.lampdeng.com



Nov 02, 2013 | JVC Dla X3 3d Projector

1 Answer

Jvc dlax30bu


when i plug in power x30 jvc dila is red light on and lamp light on and the waning light r 6 time flash again and again

Feb 25, 2013 | JVC "DLA-X30 D-ILA 3D Projector"

1 Answer

JVC DLA-RS1U Projector turns off


I have a similar problem. JVC Project (DLA-RS1) shuts off after about 30 min to 1 hour of use. Everything turns off - bulb, fan, even the little light on the projector near the buttons. After 10-15 min the red light comes back on and you can start the projector.

I have seen this happen when I had installed a knock-off bulb. I believe the bulb runs a little hotter and the projector over heats. Now I am seeing it happen even with a JVC bulb.

I am in the process of taking the cover off the projector to see if anything is blocking the air flow (like a piece of broken bulb, which did break a while back). If a problem doesn't show up there I am going to check the fan to see if it is turning at full speed (maybe replace with a beefier fan?).

Does anyone have instruction on dis-assembly?

Apr 17, 2012 | JVC DLA-RS1U Projector

1 Answer

My data projector eiki LC-Xb23 goes off without warning and the warning light is flashing


If the power light & warning light both flash red, this indicates that the projector is overheating. Once the projector has cooled down the warning light would continue to flash red and the power light would be solid red.

You should clean the air filters.

The filters are located on the underside. Disconnect all cables and invert. remove the 2 air filters located at the front and rear by pullingthe latches. They are both rectangular in shape.

Being very careful not to damage them, you should rinse the dust out and leave them to dry fully before replacing them in the projector.

This should cure the problem.

Feb 17, 2011 | Eiki LC-XB23 XGA LCD Projector Multimedia...

1 Answer

Power indicator /red/ and warning led/red/ are lighting after ea 15 sec. a lamp never start and fans goes in OFF mode. I checked power supply lines S5V,S-5V,S16V on the Main Board . I checked unit lamp...


If power indicator light red and warning indicator red flashing than according to user manual :-
The projector has been cooled down enough and the temperature returns to normal. When turning ON the projector the WARNING indicator stops flashing. CHECK AND CLEAN THE AIR FILTER.
Experience:- 1. if the temperature is very low than temperature sensor maybe misbehave.
2. If anyone fan not working
so please you check fans.
(If lamp or lamp ballast unit faulty than after a time period the lamp indicator light ON not a warning indicator. I experience many times if any fan in projector are broken or jamed the temperature light if present otherwise warning light ON or flashing)

Jan 20, 2011 | Sanyo PLV-Z4 Multimedia Projectors

1 Answer

My display keeps shutting off five minutes after starting to watch TV- the sound continues, but the screen is black and the red warning light flashes


Hi,

Please check the sequence in which your warning light flashes.

I will tell you what might be the problem according to the fashing of warning light,
If,

Flashing repeatedly --- Improper voltage supply
Flashing once --- Malfunctioning of fan
Flashing twice ---excessive temperature
Flashing 3 time or more--other problem

When flashing occurs please remove the power cord from receptacle and inform your dealer about the flashing sequence.

Thanx

Jul 02, 2010 | Fujitsu Plasmavision 42" TV

1 Answer

Tv desn't turn on,power light just flashes ten times and then stops and then again


Error Indication Information
Error No. Error Information ERROR DESCRIPTION LAMP LED OSD LAMP OFF
(Note 3) (Note 4)
POWER LED TEMP LED
Note:
1.When any of the above errors has occurred, the LED will flash as shown above every 5 seconds.
2.When two or more errors have occurred at the same time, the LED will light up or flash as shown above, and then
change to another every 5 seconds in turn.
3.Warning OSD appears when the Air Filter is clogged 90%, accumulated operation time of the Lamp reaches 5000 hours,
or accumulated operation time of the Air Filter reaches 400 hours.
4.LAMP OFF: The LED will flash right after the Lamp goes off.
5.IC2301 is mounted on LCD Main C.B.A. which is included in the Projection Unit.
6.IC6001 is mounted on TV Main C.B.A.
Clogged air filter
more than 90%
15)
16)
17)
18)
1)
2)
3)
4)
5)
6)
7)
11)
8)
9)
10)
12)
13)
14)
- flashes 5 times -
every 5 seconds
IC2301(pin82) detects the clogged air filter, then indicates the
error when the air filter is clogged 90%.
Front Fan stop or
Lamp Fan stop
flashes orange
once every
5 seconds
- -
IC2301(pin12) detects the Front FAN stop or Lamp
FAN stop, then indicates the error when the Front FAN
or Lamp FAN is stopped.
Lamp Cover open
Temperature Sensor
short or open
flashes orange
twice every
5 seconds
flashes orange
3 times every
5 seconds
flashes green for
140 seconds.
flashing red for
60 seconds.
light up red.
flashes once
every 5 seconds
flashes once
every 5 seconds
flashes red for
10 minutes
flashes once
every 5 seconds
-
-
-
-
Abnormal
Temperature
flashes twice
every 5 seconds
flashes twice
every 5 seconds
- -
Request for Lamp
Replacement - - lights up
Power Ballast Error
(abnormal
Lamp voltage)
- -
flashes 3 times
every 5 seconds
Power Ballast Error
(abnormal
temperature)
- -
flashes 4 times
every 5 seconds
Power Ballast Error
(other causes) - -
- -
Request for Filter
Cleaning -
Abnormal Voltage
on 16 V line of
LCD Main C.B.A.
-
flashes twice
every 5 seconds
flashes twice
every 5 seconds
Abnormal Voltage
on 14 V line of
LCD Main C.B.A.
-
flashes 3 times
every 5 seconds
flashes 3 times
every 5 seconds
Abnormal Voltage
on 7 V line of
LCD Main C.B.A.
-
flashes 4 times
every 5 seconds
flashes 4 times
every 5 seconds
IC2301(pin76) detects the Lamp Cover Unit condition
(open or close), then indicates the error when the
Lamp Cover Unit is open.
IC6001(pin85) detects the Duct FAN stop, then
indicates the error when the Duct FAN is stopped.
IC2301(pin74 and 75) detects open or short of the Temperature
Sensor (R2911) on Front Thermistor C.B.A., then indicates the
error when Temperature Sensor is open or shorted.
(The error is not detected for 1 minute after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Front FAN by the Temperature Sensor (R2911) on Front
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 43 C (109 F).
(The error is not detected for 1 minute after Lamp ON.)
IC6001(pin86 and 87) detects open or short of the
Temperature Sensor (R2901) on Lamp Thermistor C.B.A.,
then indicates the error when Temperature Sensor is open or
shorted.
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin74 and 75) detects the temperature attached near
the Lamp by the Temperature Sensor (R2901) on Lamp
Thermistor C.B.A., then indicates the error when the
temperature becomes more than 60 C (140 F).
(The error is not detected for 4 minutes after Lamp ON.)
IC2301(pin11) detects the error of LCD Power C.B.A.,
then indicates the error when the temperature fuse
(117 C)(243 F) in LCD Power C.B.A. is open.
IC2301(pin11) detects the error of LCD Power C.B.A. and Lamp,
then indicates the error when an inner malfunction of LCD Power
C.B.A. occurs, the Lamp voltage becomes more than 130V or
less than 30V, Lamp current becomes more than 5A, or the Lamp
is cracked.
IC2301(pin11) detects the error of the Lamp, then indicates the
error when the Lamp is short-circuit.
IC2301(pin48) detects +16V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +13V.
IC2301(pin47) detects +14V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +11V.
IC2301(pin45) detects +7V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +5.7V.
IC2301(pin44) detects +3.3V line voltage on LCD Main
C.B.A., then indicates the error when the voltage
becomes less than +2.5V.
flashes 3 times
every 5 seconds
flashes 4 times
every 5 seconds
Abnormal Voltage
on 3.3 V line of
LCD Main C.B.A.
-
-
-
- flashes 5 times
every 5 seconds
Forced cooling
The failure of Lamp
light up
-
Temperature Sensor
short or open
-
-
Abnormal
Temperature
Duct Fan stop -
When accumulated operation time of the the Lamp reaches
5000 hours, OSD (replacing the Lamp) appears on the screen.
Note: The Lamp time is stored in EEPROM (IC2305).
When accumulated operation time of the Air Filter reaches 400
hours, OSD (cleaning the Air Filter) appears on the screen.
Note: The Filter time is stored in EEPROM (IC2305).
During forced cooling, this indication is indicated.
IC2301 (pin11) detects the failure of light up processing of
the Lamp, then the POWER LED is changed as follows.
1) POWER LED flashes green for 140 seconds (while turning on).
2) POWER LED flashes red for 60 seconds (while cooling).
3) POWER LED lights up red (standby).
Note: If the Lamp will not light after attempting turning on the
power 2 or 3 times, the Lamp, the LCD Power C.B.A. or the
LCD Main C.B.A. may be defective.
Error Symptom Problem Possible Solutio

May 30, 2010 | Panasonic Viera TH-50PX80U Plasma TV

Not finding what you are looking for?
Televison & Video Logo

Related Topics:

123 people viewed this question

Ask a Question

Usually answered in minutes!

Top JVC Televison & Video Experts

The Knight
The Knight

Level 3 Expert

74198 Answers

Jaime Hernandez

Level 3 Expert

2318 Answers

Henry  Thomas
Henry Thomas

Level 3 Expert

1074 Answers

Are you a JVC Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...