Circuit breaker for airconditioner keeps tripping we have central air

Posted by on

Ad

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that hasĀ over 10 points.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 7 Answers

If the circuit breaker trips right away then I would suspect a dead short somewhere. If the unit runs a little then I would check the contactor at the unit. Turn off the breaker and activate the contactor a couple of times. The contacts could be a little sticky. Hope this helps.

Posted on Jul 23, 2009

Ad
  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that hasĀ over 10 points.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 18 Answers

You really need a service guy sorry

Posted on Jul 18, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How do i fix my central air conditioner from tripping the circuit breaker?


tripping circuit breakers indicate shorts in the system or overload from a compressor failure
call in a technician to properly diagnose the problem and get a quote

Jun 01, 2016 | Heating & Cooling

1 Answer

We have a 1999 "Thermal


DO NOT install a 20 amp breaker, you can cause a fire. The breaker is rated for the WIRES, and unless you change out the wires, the 15 amp wires will overheat and can cause a fire.
Typically, A/C units need dedicated power, with nothing else on that circuit.
One step that you may try is a new 15 amp breaker. Once a breaker starts tripping, is starts tripping earlier....
You may wind up running a new circuit for the A/C, if you do, size it for the A/C.

Jul 18, 2011 | Heating & Cooling

1 Answer

Breaker keeps tripping on outside air conditioner unit


The compressor is probably drawing to many amps. Breaker could be weak also.. Need to check the amp draw on the compressor.

If the breaker is hot when it blows, the compressor is probably going bad.

Jul 27, 2010 | Ruud Central System Air Conditioner

1 Answer

SL24J30 KILLING CIRCUIT BREAKER


Hi,

Here is a tip that I wrote that will help you ti find out why the circuitbreaker is tripping.

Circuit Breaker Keeps Tripping
heatman101

Jun 24, 2010 | Friedrich SL24J30 Air Conditioner

1 Answer

The furnace part of my central air is wired to a seperate breaker but keeps tripping the breaker and making a spark in the breaker box.


Usually a Central Unit is wired seperate, the Air handler inside and the
Cooling unit outside. It appears that the breaker is bad, is it a Single Pole Breaker?

Another possibility is that the indoor blower motor might be bad.

Jan 10, 2010 | Heating & Cooling

1 Answer

Air conditioner trips circuit only in the evening?


first off, it's illegal to release freon into the atmosphere. the epa could charge you $32,500, so keep it under your hat. second, if it's getting too cold where the evaporator coils are icing up, it's too lille freon, not too much. as for the breaker tripping, your compressor might be wearing out. if it's pulling too much current, the motor is failing and the compressor needs replacing. and do not do it yourself unless you're certified by the epa to move freon and have the proper equipment to recollect the used freon.

Jul 29, 2009 | Heating & Cooling

1 Answer

Central AC unit replaced breaker trips after running 20min


Unit is drawing two may amps for the breaker. Could be compressor sticking.

Jul 22, 2009 | Weather King 10AJA6001AH Air Conditioner

1 Answer

Central air conditioner keeps tripping breaker


first when you reset the breaker stand off to the side circuit breakers can explode i've seen it happen sevral things will cause this 1 a shorted compressor. bad start components or contactor if compressor is pulling locked rotor amps you need a compressor a stuck compressor can some times be un stuck. you need a cotractor. Tom

Jun 18, 2009 | Heating & Cooling

1 Answer

Air conditioner pop and then blew refriderant or something


Inspect the capacitor for failure. if it is not swollen or leaky then the compressor might be gone.264f733.jpg

Jan 08, 2009 | Kenmore Room Air Conditioner

Not finding what you are looking for?
Blue Sea Sea 3082 Dc 10 Position Toggle Branch Circuit Breaker Panel Logo

Related Topics:

139 people viewed this question

Ask a Question

Usually answered in minutes!

Top Blue Sea Boating Experts

Steve
Steve

Level 3 Expert

693 Answers

ray gallant

Level 3 Expert

45225 Answers

Fabrice Wolters

Level 2 Expert

320 Answers

Are you a Blue Sea Boating Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...