Mine did this and after increasing water flow it stayed on. Service guy said it needs to see a good flow rate to stay on.??? Worked for mine,.

Posted on Aug 10, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How can i tell if my toyostove laser72 igniter is working properly after i have removed it from the unit


If the igniter is still out of the heater, it will get hot enough to burn you in just a couple of seconds if you turn the heater on. You can test the igniter with an ohmmeter. If you connect the ohmmeter to the 2 ends of the igniter you should get 10 - 17 ohms if it is good. With the igniter installed in the heater you can put a clamp on ammeter around just 1 of the leads for the igniter and should get between 2 - 5 amps if it is working. You can also feel the cap over the end of the igniter. Turn the heater on and the cap should start to get warm in 30 - 60 seconds but may take longer. Also, if the igniter is not working you will not see any flame after the 3 minute warm up the heater goes through. Of course this could also be caused by a lack of fuel. The quickest way is either the ohmmeter or ammeter and takes any guess work out it.

Dec 26, 2010 | Rinnai Toyostove Direct Vent Heater:...

1 Answer

I have a 2 year old rheem power vent water heater model # 42vp50fw. It suddenly stopped working. It will try to ignite. The igniter will glow and the call for gas will ignite the burner. After a few...


Hi,

The flame sensor is bad....and it is not sensing that the flame has lit....

Some models have a separate flame sensor and some use the ignitor to sense the flame...

If it has a separate sensor then clean it with a soft cloth... if it is the ignitor then the ignitor is bad...

heatman101

Nov 25, 2010 | Rheem 50 Gallon FVR NATGAS Water Heater...

1 Answer

Water heater runs for 40 seconds or so and stops, smell oil oder


Hello STOP!!!!! don't push the reset button any more.You have a ignition/spark problem.You will load the chamber with oil and will cause major problems when it lites off.Replace the ignition TRANSFORMER on the burner.Avalible for (beckett burner) at home depot/lowes.

Sep 20, 2010 | RTO Bock Water Heaters 51E 50 gal 152,000...

1 Answer

Fails to ignite - fan blows for 15 seconds, then 2


i had the same problem it turned out to be an old regulator valve on the gas meter wasnt allowing enough gas to reach the heater. i had to have the gas comapny come out. they changed it for free.

Jul 03, 2009 | Hayward H Series Pool & Spa Heater 400k...

1 Answer

Laars Teledyne Pool heater flames on for 2 seconds, shuts off


pull out flame sensor and clean with sand paper or emmoring cloth then try again should work (small black wire with sensor sitting above burners)

May 05, 2009 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Hayward Spa Heater ignites for 2 seconds and shuts off.


Sounds like this is a flame sensor issue. It is not detecting the flame.

Nov 06, 2008 | Hayward H Series Electronic Ignition...

Not finding what you are looking for?
Teledyne Laars Laars Lite 2 Pool Heater 325,000 Btu / Natural Gas  Logo

Related Topics:

183 people viewed this question

Ask a Question

Usually answered in minutes!

Top Teledyne Laars Pool & Spa Experts

paulcarew

Level 3 Expert

2458 Answers

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

Bill Jordan

Level 2 Expert

372 Answers

Are you a Teledyne Laars Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...