Question about Maytag M7DH45B2A Dehumidifier

Open Question

Power is on and all the light are showing but the fan not running.

Posted by Anonymous on

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Followed turn on instructions in manual.CO display 2 days. continually. Unit gets Very warm & fan runs if turned off. Have to unplug to stop. Unit used approx.3 mo in '14 & just restartd this week.


could you be mistaking the room humidity indicator for the time? reason I ask is on these one display units this happens more frequently than Id care it too , the one display shows both time and room humidity also set point humidity , the only way one can tell is on some models there is a tiny light that shows up next to labeled function , easy to miss It , also if your machine is sort of new (last few years) it has been decided that it's more efficient to let the circulation fan run all the time , regardless of room humidity . this makes it a little annoying (noise) but they do cycle the compressor to regulate the room humidity

May 28, 2015 | Dehumidifiers

1 Answer

"bucket full" indicator on - running a hose


Since you have had 2 seemingly unrelated symptoms it is almost sure you have had a power board failure. If you post back with the complete model number we will try to check everything and see what we can come up with.
Thanks/Mike

Oct 25, 2007 | Kenmore 54701 Dehumidifier

1 Answer

It seems the unit fan runs but the condenser doesn't work. When first turned on the fan runs and the display shows 85%, with the setting at 55%, and four hours later the fan is still running but there's...




Hi,


There are many reasons why a dehumidifier will not work or collect water.


Here is a tip that I wrote to help people to figure out what is going wrong with their dehumidifier

Dehumidifier is running but no water is in bucket

heatman101

Jan 16, 2011 | Frigidaire FDF50S Dehumidifier

2 Answers

Fan will not come on.


The fan has to run if the compressor is running as the fan assists in removing the heat from the condenser coil. Can you spin the fan by hand? If there is full power(120 volts) to the fan and it isn't running then the fan motor is bad. Also, if the fan motor has a run capacitor this could keep the fan from running(if the capacitor is defective) so look for this first.

Nov 15, 2009 | LG LHD45EL Dehumidifier

1 Answer

Kenmore Dehumidifier Isn't Running


It sounds like you have power to the unit but a component is failing to start the system get an AC tech to check it.

Jun 08, 2009 | Kenmore 54501 Dehumidifier

1 Answer

Dehumidifier not collecting moisture


Normal 0 When you push the power button, the blower fan comes on. In a few minutes you should hear a second "click"--that is your compressor starting. Do you hear that second click?

Jan 31, 2009 | Kenmore 54501 Dehumidifier

Not finding what you are looking for?
Maytag M7DH45B2A Dehumidifier Logo

Related Topics:

177 people viewed this question

Ask a Question

Usually answered in minutes!

Top Maytag Dehumidifiers Experts

Michael Van Der...
Michael Van Der...

Level 2 Expert

66 Answers

Bill Long

Level 3 Expert

587 Answers

Steve

Level 3 Expert

3287 Answers

Are you a Maytag Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...