Question about Filter Heating & Cooling

1 Answer

Y does reset come on controller after 30mins running just after cleaning ra filter

Posted by Anonymous on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Top Expert:

    An expert who has finished #1 on the weekly Top 10 Fixya Experts Leaderboard.

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

  • Filter Master
  • 10,875 Answers

Reset it so it knows when to tell you to clean the filter

Posted on Apr 16, 2015

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

Tip

How to Reset Your Air Conditioner Filter Light


<span style="font-weight: bold;">Cabin Air Conditioner:</span><br /> <ol> <li>Press and hold down the Off button for 4 seconds.</li></ol><span style="font-weight: bold;">Carrier Air Conditioner:</span><br /> <ol> <li>Press the Reset Filter button to reset the timer that calculates the next air filter change after you have inspected / cleaned the indoor return air filter.</li></ol><span style="font-weight: bold;">Daikan Air Conditioner:</span><br /> <ol> <li>Press the Filter Clean Reset button to reset the CLEAN FILTER INDICATOR after you have inspected / cleaned the indoor return air filter.</li></ol><span style="font-weight: bold;">Frigidaire Air Conditioner:</span><br /> <ol> <li>To reset after cleaning the filter, press the "Filter Reset" button and the light will go off.</li></ol><span style="font-weight: bold;">GE Air Conditioner:</span><br /> <ol> <li>Turn the air conditioner OFF and unplug it.</li> <li>The air conditioner must be unplugged for the automatic filter clean timer to reset. Clean the filter.</li> <li>After cleaning, replace the filter and plug the air conditioner back in.</li></ol><span style="font-weight: bold;">Honeywell Air Conditioner:</span> <ol> <li>Press and hold the i button until the timer is displayed, followed by pressing the Up Arrow button (next to the Wake button)</li> <li>Press the Run Program button.</li></ol><span style="font-weight: bold;">Kenmore Air Conditioner:</span><br /> <ol> <li>To reset the filter indicator, press and hold the filter reset button for 3 seconds.</li></ol><span style="font-weight: bold;">Lexus Air Conditioner:</span><br /> <ol> <li>Without having foot on the brake, press the Start button twice to get to the IG-ON position.</li> <li>Then press and hold the "hard" OFF button next to the "hard" Auto button. Hold the OFF button for approx 5 seconds and you hear several beeps.</li></ol>or<br /> <ol> <li>Turn the engine switch to IG-ON mode.</li> <li>Push and hold the A/C OFF button for more than 4 seconds.</li></ol><span style="font-weight: bold;">Lexus 2008 Air Conditioner:</span> <ol> <li>Push the "INFO" button & touch "Maintenance".</li> <li>Touch the desired button Delete All: To cancel all conditions which have been input or Reset All: To reset the item which has satisfied a condition. If "ON" is selected, the system gives maintenance information with the "Information" screen when the system is turned on. If "OFF" is selected, the "Information" screen is disabled.</li> <li>Input the Notice of Date: The next maintenance date must be input.</li> <li>Now input the Notice of Distance: The driving distance until the next maintenance check.</li> <li>Delete: To cancel the date and distance conditions.</li> <li>Reset: To reset the date and distance conditions.</li> <li>Touch "OK" The screen returns to the "Maintenance screen.</li></ol><span style="font-weight: bold;">Lincoln LS 2001 Air Conditioner:</span><br /> <ol> <li>Press and hold the setup button above the radio until it says system check. NOTE: All the doors must be closed.</li> <li>Watch the system check when it goes to A/C filter hit the reset button.</li> <li>Hold down the reset button to confirm.</li></ol><span style="font-weight: bold;">Lincoln LS 2003 Air Conditioner:</span><br /> <ol> <li>Press the STATUS control to access the System Check function, the message center will display A/C FILTER XX% RESET FOR NEW.</li> <li>Press and hold the RESET control to set to 100%.</li></ol><span style="font-weight: bold;">Lincoln LS 2005 Air Conditioner:</span><br /> <ol> <li>Insert the key and turn the ignition to "Run" or "On." It is not necessary to start the engine.</li> <li>Press the "Status" button above the radio until the system display changes to "AC Filter."</li> <li>Press and hold "Reset" above the radio. The system will beep and the "AC Filter" display resets to "100%."</li></ol><span style="font-weight: bold;">Maytag Air Conditioner:</span><br /> <ol> <li>Press the "Fan" button 2 times, then press the "Mode" button 1 time and it will reset.</li></ol><span style="font-weight: bold;">Whirlpool Air Conditioner:</span><br /> <ol> <li>Push in the filter reset on the remote using a straightened out paper clip or similar.</li></ol>or<br /> <ol> <li>On the control panel, press and hold the Mode and the Up Temp Arrow buttons for 6 seconds.</li></ol>or<br /> <ol> <li>After having cleaned the filter just press the reset button located on the indoor unit behind the front panel to interrupt the flashing of the filter monitor indicator.</li></ol>

on Jun 17, 2011 | Heating & Cooling

1 Answer

I have an older meade LX2000 EMC 10


The main problems encountered with the mechanics of the telescope centre around the mechanical swarf, grease compound, the liberal use of grease and the quality of machining of the main DEC and RA gears.
1. Remove the motors from the telescope. Be careful when removing either motor as there is a compression spring between the motor mounting frame and the worm shaft assembly.
The RA motor is located under the telescope body, removing the 4 screws and 2 Allen bolts will allow the bottom cover to be removed, thereby allowing access the the 2 Allen bolts holding the motor in place. Unplug the motor from the main PCB before removal.
The DEC motor is in the the fork arm containing the clutch and fine DEC adjustment control. (Never to be used with power applied to the scope). Remove the 3 small Allen screws holding the plastic cover plate in place and the DEC clutch knob to allow access to the motor. Remove the RJ45 connector located inside the telescope fork arm. Then remove the motor by unscrewing the 2 Allen bolts holding the motor in place.
2. Remove all grease from the motor worms, especially around the RA motor's magnetic pulse detector and the permanent magnet built into the worm shaft.
3. Remove all grease from the main DEC and RA gears, making sure to clean into the gear teeth.
4. Lightly re-grease with a Molybdenum Disulphide based grease (Castrol MS3 is great for this application if you can get it)
5. Assemble in reverse order. But before doing so, carry out the electrical adjustment above then, (a) relocate the the RA and DEC control PCB's in the vertical plane thereby gaining access to their respective backlash Allen screws. Adjust for 20thou max clearance when in final position. Note:- the DEC adjustment screw has to be replaced for a longer unit complete with a thin bolthead as this adjustment has to be carried out with a spanner....there is no room for an Allen key adjustment here.
6. A drop of Loctite must be applied after adjustment.
7. The final part of the process is to run in the gearing. Apply 12 volts to the motor wires, either at their respective plugs or to the motor direct. Allow to run for 2 to 3 hours in each direction by reversing the battery polarity to bed the teeth engagement. Remember to release the clutches.

Dec 28, 2011 | Optics

1 Answer

Frigid 30 in walloven broiler and oven coils not heating after running self cleaning cycle


Just had this problem, and the solution was manual reset thermal disc located on back of oven. Press red button to reset.

Oct 22, 2011 | Frigidaire FEB30S5GC 30" Single Electric...

1 Answer

The projector over heats in 30mins


Make sure all of the airways are clean and the filters.
Is the light old? If it is it may produce too much heat.

Jan 06, 2011 | Epson EMP 835 Multimedia Projector

1 Answer

After running self clean the display shows E1 and F5 and the door will not unlock. How do I unlock the door and reset the display?


The only real thing you can try is to unplug the unit or turn breaker off for about 30mins too see if it resets the board. The E1 F5 is a door lock error so hopefully pulling power from it awhile will work.

Oct 13, 2010 | KitchenAid KERC506 Electric Kitchen Range

1 Answer

RA will not track on Orion Atlas mount


Are you sure it's not actually working (tracking)-- can you hear the motor running?

I would contact Orion and make sure you have a manual for the hand-controller-- it may have a setting that turns tracking on or off.
http://www.telescope.com/control/main/

Nov 14, 2008 | Orion Atlas Mount GoTo Upgrade Kit...

1 Answer

2005 52in Panasonic rear projection


Try either cleaning the filter.......or check the bulb.....it may need to be replaced.

Oct 26, 2008 | Televison & Video

2 Answers

Frigidaire Gallery Self Cleaning Oven


F1 code on frigidaire is bad EOC (clock) Try shutting breaker off 20-30mins see if it resets itself.

Jul 12, 2008 | Kitchen Ranges

1 Answer

Clean Filter Signal continues to appear even after the filter is cleaned.


you have to reset the filter in the controls or it will continue. i cleaned it everyday for a week until i got fed up and went into the last setting (by the lamp hour reset) and reset it. good luck

Dec 06, 2007 | NEC VT470 Multimedia Projector

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

24 people viewed this question

Ask a Question

Usually answered in minutes!

Top Filter Heating & Cooling Experts

yadayada
yadayada

Level 3 Expert

75016 Answers

Coss

Level 3 Expert

1056 Answers

MightyMikeJr

Level 3 Expert

388 Answers

Are you a Filter Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...