Question about Heating & Cooling

Open Question

Display in my gree split type aircon shows H6. The unit won't operate.

Posted by on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
rayname
  • 70 Answers

SOURCE: AC remote not working

www.gree-ac.com this is gree website you will need a model and serial number from unit I would contact them to see who your local suppliers are or online order remote m# and s# would also help if available

Posted on Jan 04, 2009

Ad
  • 400 Answers

SOURCE: WATER LEAKING FROM MY SPLIT TYPE LG AIRCON

1. Do not set the aircon too low temperature in overcast weather, this will cause ice ups and water dripping. Optimal comfort zone temperature is 24c.
2. You need to open the grill cover on the front of the aircon which unclips either end left and right with a finger pressure. You will find two filters which can slide out and should be cleaned. First tap them together to remove dust, then you can wash them with mild soap and cold water.
3. There is the third possibility that an insect has made a nest in the drainpipe. You should look on the outside of the building and locate a plastic drainpipe. You can either blow into this pipe with your mouth or get a blower. This will unblock any restriction in the drainpipe.
Goodluck and ratemeplease.

Posted on Mar 19, 2009

koolbreezes
  • 540 Answers

SOURCE: My fujitsu split type aircon is not working, the

Can you check the service manual for the diagnostic code?

Posted on Dec 22, 2009

hvac1960
  • 2133 Answers

SOURCE: indoor unit flashes 5 times. error code meaning?

E-5 -Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4

Posted on Jan 03, 2011

  • 1 Answer

SOURCE: my carrier split type non-inverter aircon always blinking

I got the same problem in Samsung aircon. The unit I purchsed died slowly. After that Samsung replaced it with the one have the same problem. They are swearing that the green light blinking problem as a normal function and refusing to fix. Their user manual says it is a problem. I think the affected consumers should join hands to take legal action against this scam.

Posted on Dec 20, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

When the indoor unit is on F4 fault error code display.please help to solve the problem.


f4 mean Air Conditioners Questions & Answers - Fixya

www.fixya.com > Forum > Tags > f4 mean
My gree split type ac error F4 what is problem Name of malfunction = Outdoor tube sensor open or short circuit Display of double eight code = F4 this means

Oct 29, 2015 | Heating & Cooling

1 Answer

Hi,I have a gree Airconditioner and its displaying H6 error,what should I do?


Google search your manufacturer make and model and the words error H6. You can find it in the search results, which will get you started.

Apr 01, 2015 | Heating & Cooling

2 Answers

VIDEOCON SPLIT AC SHOWS H6 & IS NOT WORKING


Videocon Air Conditioner Shows Error Of H6 Plz Tell Me The Solution.as urgent

Apr 16, 2013 | Heating & Cooling

1 Answer

My aircon is not blowing


Most liekly needs to have freeon added to the system, if that doesn't help its propely a problem with the electric motor on the blower.

Nov 07, 2012 | Gree 9000 Btu 23 Seer Ductless Mini Split...

1 Answer

Videocon Split AC, Model VBS53 showing H6 Error. Please Help


h6 problem create a machine showing a display?

Jul 01, 2011 | Heating & Cooling

2 Answers

Unit will heat only will not cool and how to repair


we have a split type gree aircon, with one (1) horsepower. it was just newly installed, around 6 months ago. we are just surprised that one when my wife turned it on, thru the use of its remote control, the indicator box on the aircon reads or flashes "F2". I detached the batteries of the remote control for severa hours and I also detached the power cord from the wall socket, but it was to no avail. it did not work. with "F2" on the indicator box, the aircon won't give cool air, it is just working like an ordinary fan. please help us.

May 17, 2011 | Mitsubishi Mr. Slim MXZ30TN Air...

2 Answers

My carrier split type non-inverter aircon always blinking


It indicates afault within the unit. Give Carrier a call and get it serviced.
Mat

Jul 01, 2009 | Carrier 36KCARMS Air Conditioner

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

41 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

2602 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...