Question about Pool & Spa

2 Answers

How does one configure for 115 and 230 volts?

Missing wiring diagram. Jet pump duty, 1.5 HP. 230/115 volts options

Posted by on

Ad

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 1,631 Answers

What brand motor?
what model, code, catalog number?
there should be a diagram either on the side of the motor or in the back, on the cover that exposes the wire connections. Sometimes it is placed behind the rubber insulating gasket, so just carefully peel it away from the cover to possibly expose it. But... You can only change incoming voltage, IF it is a Dual Voltage capable motor? Some are only one or the other, and some are Dual voltage style.

Posted on Apr 09, 2015

Ad
  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 372 Answers

It varies. You will need to contact the mfr.

Posted on Apr 09, 2015

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Where do the wire leads connect to the switch?


Look on the id plate on the motor, and inside the cover on the back and inside the switch cover.

Jul 03, 2015 | Utilitech 1/2 HP Convertible Jet Pump...

1 Answer

Where can i find a wiring diagram


Even the company did not post that in direct response to an inquiry. That is a bad sign. So what wires are present on the unit?

Apr 14, 2014 | Utilitech 1-1/2 HP Irrigation Pump UTP15P1

1 Answer

Changeing 115volt to 230 volt


Most power Flo pumps run above ground pools and run on 115v only.You can look at the wiring diagram on the motor label to see if it is convertible, it will show wiring configurations and amps for both 115v and 230v. If not, it is a 115v motor only.

Sep 11, 2013 | Hayward Power Flo Lx 1 Hp Pool Pump Sp1580

1 Answer

I need wiring diagram for Gould Century Pump motor 1081 Part # 8-142776-20 1HP 230v/120v


www.bestbuypoolsupply.com/media/motormanual.pdf


This manual has the wiring diagrams both hi and lo voltage for
part # 8- 142776 -20 gould century 1081m 1 hp , pool pump motor 230/115 volts.... plus several similar motors

May 25, 2012 | Plumbing

1 Answer

I have a 3/4 hp Flotec 4022 pump. Prior to that I had a goulds 1 hp pump on the same 120 circuit with no issues. The Goulds pump housing started to go so I replaced it. Since replacing it with the Flotec I...


Hi Eglenni,

Here are the specs for your pump:

Thermoplastic Shallow Well Jet Pump 3/4 HP. This new revision of an "old hand" provides good pressure pumping from wells where the depth-to-water is 25' or less.

BODY CONSTRUCTION: Thermoplastic
HORSEPOWER: 3/4
MAXIMUM CAPACITY: 12 GPM
FLOW at 10' LIFT and 40 PSI: 9.7 GPM
MAX LIFT: 25'
MAXIMUM PRESSURE: 78 psi
PRESSURE SWITCH SETTING: 30/50
SUCTION PIPE SIZE: 1-1/4" NPT
DISCHARGE PIPE SIZE: 1" NPT
AMP DRAW (full load): 6.1 amps on 230v / 12.2 amps on 115v
VOLTAGE: 230v / 115v, 60 Hz
RECOMMENDED BREAKER: 15 amp on 230v / 20 amp on 115v
MAXIMUM WATER TEMPERATURE: 140 °F (60 °C)
=========================================
Note that this pump can be operated at 115 volts or 230 volts (A/C) It may have come wired for 230 volt use from the vendor.

Make sure the pump is piped correctly.


There should be a wiring diagram either on the pump or in the literature so you can check to see how the pump is wired.

MAKE SURE
you have the pump wired for 115 volt use in your case. Also make sure the wire size is #12 awg for the power wiring.
Make sure all connections are tight. If you have an amprobe (an instrument that measures electric current) you can check to see how many amps the pump is pulling when it runs.

You said your old pump was 1 HP. This Flotec pump is 3/4 horse so there could be some pump performance loss depending on the well depth and length of the piping runs.

Here's the link to the website for the pump. There are additional resources available on the website:

Thermoplastic Shallow Well Jet Pump 3 4 HP

Jul 05, 2017 | Northern Tool Electrical Supplies

1 Answer

Just replaced a Hayward 2hp pool motor with a OA Smith 2hp pool motor and when i turned it on it starts to switch between high and low and it shuts off. the motor makes a tic tic sound. What do you think...


Hello
No there is no switch in the motor.Correct voltage is done by hooking up incoming power to a combination of internal wires or contacts.

There should be a wiring diagram on the cover where the hookup is.Or on the outside case of the motor.
The high and low speed doesnt make sence to me.Check the rpm of the motor it should be one rpm continueous.
Unless this is a Hvac motor and not a pool pump motor.Possible you may have been sold the wrong motor.
Usually a pool pump is 115 volts 1 speed and 1 rpm continuos duty.Unless you specify 230 volts.

Aug 09, 2011 | AO Smith 2 HP 115/230V 56C Replacement...

1 Answer

How do I set the Waterway Champion Pump for 115 Volts? I have the same problem, just installed and it runs for a bit then shuts off. It was mentioned that the pump is usually set for 230, so how do I set...


The voltage is not optional. What voltage are you plugging the pump into?
If you are plugging it into 115, the pump must be set for 115.
If you are plugging it into 230, the pump must be set for 230.
Usually there is a wiring diagram on the label on the pump body or if you remove the end cover, there may be instructions there. There may even be a switch or terminal that states 115 volts and another that states 230 volts.
Gary

Jun 29, 2011 | Waterway Champion 1 1/2 Hp 230v Energy...

1 Answer

I need a wiring diagram for a farm duty 6k714k


It is generally located on the nameplate of the motor or inside the wiring housing where the outside power is brought in. These motors are usually convertible from 115 to 230 volt by merely switching a couple of wiring connections inside the wiring housing. If you can do so, 230 volt operation is much preferred due to the high speed start-up available and you can use wiring 1/2 the size required for 115 volt operation. Good luck!

Jun 05, 2010 | Dayton Audio Dayton 6K138 CapacitorStart

1 Answer

Looking for a diagram on a hayward pool pump electrical wiring model super 11


What specifically are you looking for (beside the fact you asked for a diagram)?

It should be setup for 220 Volts ... the only thing inside is a start cap.

Can you tell me more? I maintain 5 2 and 1 1.5 hp such pumps.

Oct 14, 2009 | Hayward Super Pump 1 1/2 - Hp for In...

1 Answer

Replacement pump for spa (Waterway Executive Euro 2 speed 2 hp


V1 would be low V2 would be high U1 would be line and then ground. A picture would be helpful to be sure.

Jul 05, 2009 | Waterway 5 Hp 230 Volt 2 Speed Side...

Not finding what you are looking for?
Pool & Spa Logo

Related Topics:

92 people viewed this question

Ask a Question

Usually answered in minutes!

Top Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1340 Answers

Bill Jordan

Level 2 Expert

372 Answers

David Spradling
David Spradling

Level 3 Expert

5075 Answers

Are you a Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides