Question about Whirlpool Water Heaters

1 Answer

I have brand new Whirlpool gas water heater and forgot to put on air filter. Have tried to light the pilot light and it will not stay lit. Can you tell me if the air filter could cause this

Posted by Anonymous on

  • Sorry to see you're having problems! Can you contact me directly so I can help? www.whirlpoolwaterheaters.com/help/answers/dc Thanks! ~ Chris American Water Heater, authorized licensee for Whirlpool Water Heaters

×

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Master:

    An expert who has achieved Level 3.

  • Master
  • 395 Answers

Not unless the system has a fault switch whereby the switch requires a filter to activate the heater. Generally Not.
As a rule, your GAS company will come to your residence FREE of charge to check the heater and start it for you.

Posted on Apr 02, 2015

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
pgh_pa_guy
  • 2992 Answers

SOURCE: pilot light won't stay lit after release of gas valve.tried few t

Most likely it's time to replace the thermocouple, the safety device that makes sure the pilot is lit. New thermocouples are cheap and you can find them at most hardware stores and the big-box places (Home Depot, etc.)

Here is a site with basic information to get you going.

Posted on Apr 08, 2009

  • 2 Answers

SOURCE: Rheem 40 gallon gas hot water heater, pilot light

To make a short story long (I need to include all details, sry)…

I got up one morning and realized that we did not have hot water. I re-lit the pilot light and as soon as the burner went out from heating the water up, the pilot light would go out. After reading several posts regarding this issue, it seemed apparent that the thermo-coupler was the problem. Since I am a little bit handy around the house and very tight when it comes to opening my wallet, I bought the device from Lowe’s ($8.98) that was recommended by my online advisors and after a few googles, figured out how to change it. No help. The pilot light still goes out.

I gave up and went to Home Depot to purchase and schedule the installation of a new hot water heater.

STICKER SHOCK

A new Direct Vent type water heater costs around $800 with an additional $450 for “special” installation. Add a few fees to that and the grand total came to about $1450.

I felt like I had no choice since my wife and 2 daughters refused to live their life without hot water and I had no clue about how to fix the dam thing.

The plumber assigned to the installation stopped by to evaluate the site conditions and quickly noted to me that the 8 year old water heater tank was in good condition and that the gas controller was probably faulty, which could be purchased online from the manufacturer. I quickly cancelled the Home Depot order and purchased the controller for about $120 after shipping and tax. Immediately after the installation it seemed that the problem had been solved. A few days later the pilot light went out.

I called the plumber and explained the situation and he recommended that I purchase another controller because the one that was shipped to me was probably bad. I searched around town and found a plumbing supply company that had the correct model in stock. Two days later the pilot light was out. I cleaned up the controller and returned it to the store and asked the plumber to please schedule a visit to repair this dam thing.

When the plumber arrived, he hooked up a gauge in several locations and confirmed that the correct amount of gas (cfm) was being delivered to the controller, pilot light and burner. He then proceeded to remove the fire box to make sure that the igniter, thermo-coupler and pilot tip were set properly. He inspected the pilot light tip and said that he found the problem. Using about a 1/64” tip drill (can be purchased at a welding supply store), he cleaned the tiny hole that releases gas to the pilot light. I felt a sigh of relief because I was certain that the problem had been solved. $65 dollars (plumber’s fee for an hour of work) and 4 days later the pilot light went out.

I called the plumber and he said that the controller that I purchased online must be bad. Too embarrassed to return to the first plumbing supply store, I found another one in a different town that had the correct model in stock. Three days after changing the controller the pilot light went out. I returned the controller and a six pack later I decided to do some extensive googling.

The key term here is “DIRECT VENT”. This seems to be a very common problem with direct vent water heaters and I was about to find out the reason for this phenomenon. I read a post by an individual who wrote that if the vent becomes detached that the inflow of air can become contaminated and extinguish the pilot light. I decided that before I spent any more money on a plumber that I was going to take the vent apart and find out what makes it tick.

My direct vent system has 2 parts to the venting, an inner pipe (3” nominal diameter) that serves as the exhaust and the outer pipe (5” nominal diameter) that serves as the internal flow of air which supplies the pilot light and burner with oxygen. On the outside of the house a vent hood helps to segregate the two by extending the exhaust about 3” beyond the intake. I looked into the hood at the end of the pipes and discovered that the internal pipe which consisted of a 2 piece slip joint had come loose from the elbow that sets on top of the water heater. This slip joint pipe was not attached at any point with screws or clamps and was loosely setting over the elbow on one end and into the hood on the other end, allowing it to detach. Apparently, when atmospheric conditions were right, the burner idled down from heating up the water and extinguished the pilot light because the intake was saturated with CO2 from the connection failure.

I purchased a section of 3” pipe that was long enough to be installed in one piece. I connected it to the elbow using a stainless steel hose clamp. I had to disassemble the pipe 3 times to make adjustments to the length and position before I got it right, but I should not have any more problems with the pilot light.

The problem here is time. It takes a lot of time to get this right. When the plumbing contractors installed this unit during the construction of the house, there was no one around to make sure that they got it right. It is probably common to use a 2 piece slip joint type connection, but I feel like it should be attached with screws or clamps. In my opinion it is not rigid enough and can detach easily, especially if it is not installed properly. A one piece connection that is attached at one end with a hose clamp and then held in place at the other end by the hood is fool proof.

Posted on Sep 27, 2009

john224
  • 1378 Answers

SOURCE: Natural gas hot water heater not stying lit

Probably a bad solenoid in the gas valve. Higher voltage of a new thermocouple keeps it open longer but it still fails over a period of time. Look into a new gas valve for the water heater.

Posted on Dec 17, 2009

kel1guy2002
  • 3740 Answers

SOURCE: pilot light on water heater wont stay lit

The thermocouple has failed. It is the temp probe that goes from the pilot lite burner area to the control valve. Go to your local plumbng repair shop and buy one. Most appliance parts stores have them also. Take the old one with you and they will hook you up with an exact replacement. They are not that hard to change. Usually a nut or 2 screws in the temp bulb area at the burner end and a nut that threads into the control valve.
Make sure before you install the new one that the area where it mates to the gas valve is clean. Should be about a 20 min job including clean up with replacement parts in hand.

Posted on Jan 23, 2010

Testimonial: "exactly what I wanted yo know. thank you"

  • 1 Answer

SOURCE: Pilot won't stay lit in Reliance 606 gas water heater

The Reliance 606 has an enclosed thermal couple. Before you try taking that assembly apart take a wire brush to the bottom opening directly under the burner. There is a metal filter on the very bottom of the water heater. It could be that the filter has gotten filled with dust or animal hair. It took a serviceman 2 days to figure this out for me. The water heater has to have good airflow through that filter to work well.

Posted on Sep 29, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Whirpool water heater unable to lit


Whirlpool water heaters are made by American-AOSmith.
Approximate age of water heater is unknown, and type of gas control valve is unknown.

Clean air intake located bottom of heater, using a feather duster.
Get more fresh air to the water heater and see if that solves problem.
http://waterheatertimer.org/images/State-select-air-intake-400.jpg

If you have piezo igniter, then check if it is putting off spark.

If there is no gas at the pilot, then gas control valve is probably bad.
http://waterheatertimer.org/pdf/How-to-replace-water-heater-gas-valve.pdf

If pilot will light but not stay lit, then change thermocouple.
Watch videos on utube to lean how to replace thermocouple.

For pilot light problems: Read information on following link:
http://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.html#pilot

Jul 27, 2012 | Water Heaters

1 Answer

Lowe's hot water heater pilot light will not stay


Hi,

If it is one of the new ones with the fancy gas control and the blinking light... does the light blink?? or not??
If it is blinking then the pilot should stay lit...
If it will not blink then the sensor is bad or not in the right place...

Or... the gas control is bad... this is happening alot...

If it is brand new... take it back...

heatman101

Sep 05, 2011 | Whirlpool Water Heaters

1 Answer

Pilot light won't stay lit on new water heater


1) Get more air to the water heater and see if problem continues.
2) Read the following pdf-s for things that might apply to your situation.
http://waterheatertimer.org/images/Negative-pressure.jpg
http://waterheatertimer.org/pdf/Attic-Ventilation-and-Pilot-Outage-in-Gas%20Water-Heaters.pdf
http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf

3) Read pdfs above first, and then Add a comment with missing information below, for possible do-it-yourself help.
Does this water heater have a blower?
Is gas valve electronic? Or does gas valve have a dial?
If gas valve is electronic, have you checked outlet with circuit analyzer?
Did pilot light work correctly for a while? If so how long?
Where is water heater located? Hot attic? Closet? Garage? Is area dirty and dusty? Has air intake been cleaned?
What color is pilot flame? Clear blue or yellow-or-orange?
Have you inspected inside of combustion chamber for dripping water?

Aug 28, 2011 | American Standard 40 G Natural Gas Water...

2 Answers

I have an old whirlpool gas water heater and the pilot will not stay lit.


Suspects include bad thermocouple, thermocouple slipped down and not in pilot flame, dirty combustion parts and pilot tube, dirty air intake, backdraft caused by other vent fans pulling air down water heater vent, water dripping down vent because of poor venting, air in gas line, low gas pressure, bad gas control valve, hot attic environment, tight house not allowing enough air:

Replace thermocouple:
http://www.youtube.com/watch?v=v0aBPsNg6vo
http://www.youtube.com/watch?v=xGQngzqrIEE&NR=1
Troubleshoot pilot:
http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf
Clean combustion parts.
http://waterheatertimer.org/How-to-install-gas-water-heater.html#clean

Aug 24, 2011 | Water Heaters

1 Answer

Reliance 606 natural gas water heater - model #640YORT - water does not stay hot. pilot has to be clicked to heat and then u can use hot water til tank empty and it will not continue to heat water.


If I understand correctly, the pilot light is not staying lit.
You light the pilot and water in the tank reaches temperature.
Once hot water is gone, then pilot light has to be lit again.

Gas pressure is good, and gas is flowing.
Thermostat is working at high end because it cuts off heating.
Vent is working because tank heats up.
Air intake is working.

Gas control thermostat might not be reading low temperature. Replace gas control valve.
Pilot tube might be dirty. Clean burner parts and combustion chamber, and air intake, and vent.
Backdraft might be blowing out pilot. Check for constant updraft by running water heater 5 minutes, and then light match under vent hood and see if smoke goes up.
Very hot air can put out pilot, especially when water heater located in attic. Add ventilation.
Improper vent might have water dripping back down into combustion chamber and putting out pilot light and rusting out the parts. Inspect for rusted parts and water.
http://waterheatertimer.org/How-to-install-gas-water-heater.html#troubleshoot
http://waterheatertimer.org/pdf/Pilot-light-will-not-stay-lit.pdf

Aug 09, 2011 | Reliance Natural Gas Water Heater Control

2 Answers

Pilot light will not stay lit.


More than likely the thermal couple is defective. The thermal couple is a safety device that shuts the gas off if the pilot goes out. If it is defective the pilot light will not stay lit. The thermal couple is the device that the small copper line goes to. It is mounted beside the pilot flame and the flame much touch the TC for it to work. If the flame is not touching the TC bend it until it is in the flame. If it is touching the TC then replace it.

Jul 28, 2011 | Whirlpool Water Heaters

1 Answer

Pilot light won't stay lit in gas water heater


If this heater was manufactured after 2003 it has a FVIR filter. It is usually located on the bottom of the heater and this is where it draws air into the combustion chamber. Check to see if it is clogged with dust or lint.
because the heater probably has a sensor, it is not getting enough air and shutting off. hope this helped.

Mar 17, 2010 | Rheem 40 Gallon FVR NATGAS Low WATER...

1 Answer

Burner on new Whirlpool gass water heater will not stay lit


One of the proper ways to light a gas water heater, is to turn the black knob to Pilot, put a match to the end of the pilot light, while holding the match there, push the red reset button down and hold the match & the reset button down for one full minute. Then, release the reset button and turn the black knob to On. This should keep the pilot light on.

Jan 21, 2009 | Water Heaters

Not finding what you are looking for?
Water Heaters Logo

Related Topics:

55 people viewed this question

Ask a Question

Usually answered in minutes!

Top Whirlpool Water Heaters Experts

Donni Steen

Level 3 Expert

659 Answers

80stech

Level 2 Expert

100 Answers

jdthefixer

Level 3 Expert

744 Answers

Are you a Whirlpool Water Heater Expert? Answer questions, earn points and help others