Tried unplugging and cleaning coils and compressor
Unplug for 24 hours and replug. After 2 hours of running, temps of fridge and freezer should be close to normal and water pan should be nearly full. If so, suspect your defrost heater as needing replacing, and note that unit will behave as-is for a few days and then your symptom will return, confirming the need for the new heater. Change the small inexpensive clip-on thermostat at the same time.