Question about Toshiba Office Equipment & Supplies

1 Answer

How do i fix my toshiba studio 202s,double image result

Change uhr,drum,remove scanner and put to other unit, same problem result

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that hasĀ over 10 points.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 10 Answers

If you have replaced all that, check your drum cleaning blade and your erase lamps, these two items will contribute for Ghost images "double image". The erase lamps disperse the electrical charge so the blade can scrap the toner off the drum.

Posted on Jan 04, 2015

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 60 Answers

SOURCE: how do i fix my Toshiba studio 202s,double image problem

Drum cleaning blade may need replacing/servicing.

Posted on Dec 10, 2014

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Toshiba E-Studio 232 PhotoCopy Too Light, Why?


one simple way that may help you out , take out toner cartridge shake it to equalize toner powder , try it may work

Jul 25, 2014 | Toshiba E-Studio 232 Copier, 232 Digital...

1 Answer

Blinking panel indicator


toshiba e studio 181 control panel light blinking

Mar 13, 2014 | Toshiba e-Studio 181 Digital Copier

1 Answer

Increase the toner density toshiba copier e-studio 16


clean scanner drum unit change with good toner.

Sep 10, 2013 | Toshiba e-STUDIO 16 Printer

1 Answer

Paper prints in black


1.first clean the primery chargin unit on top of the drum(look like net).
2.clean the transfer unit.
3.if not ok change the drum.

Feb 27, 2013 | Toshiba E-Studio 232 Copier

1 Answer

Toshiba estudio 181 tonner waste


hi you have to just clean the whole mirrors in side machine and need to clean laser unit also may be its help full for you if after cleaning its good then OK if not just have to replace the drum cleaning blade and developer for good and batter results thanks

Jul 20, 2012 | Toshiba e-Studio 181 Digital Copier

1 Answer

Double imaging on toshiba 550 what is the most probable cause?


there could be two main reasons for double imaging
1) contaminated upper hot roller {replace}
2) worn drum cleaning blade {replace}

hope that has narrowed down your problem

Mar 31, 2011 | Toshiba E-STUDIO 550 Copier

2 Answers

C46 appeared on my toshiba e-studio 550 copier


C46 indicates Abnormal pressure roller thermistor during a ready state.

Perform following inspection:

1.. Clear the status counter.
Change the current status counter value (08-400) “3” or “8” to “0”.

If happen again, perform following inspection:

1. Check the pressure roller thermistor.
(1) Check if the connector is not disconnected.
(2) Check if the pressure roller thermistor closely touches the surface of the pressure roller.
(3) Check if the harness of the pressure roller thermistor is not open-circuited.

2. Check the LGC board.
(1) Check if the connector J334 is not disconnected.
(2) Check if the conductor pattern on the LGC board is not short- or open-circuited.
(3) Replace the LGC board.


Mar 05, 2009 | Toshiba E-STUDIO 550 Copier

1 Answer

Toshiba E-Studio 35 PM Kit Instructions


open front door and remove waste toner container, unplug connector and loose blue screw slide out developer unit removed top cover empty developer(100%). then open by-pass, duplex and jam access cover , remove two screws and slide out drum unit .remove charge corona. release latch on rearand remove bracket/bar( on top of drum),turn level counter clockwiseto release slide drum shaft out.remove two screw lift drum blade before install new drum & blade needdust some lubrication powder.after put everything back,hold down05 while turn onthen enter200,press start,let run about 3 minutes ,the value should bebetween 2.35-2.45 press set or interupt key same procedure doing 08then401 set to 0

Dec 15, 2008 | Toshiba e-Studio 35 Copier

Not finding what you are looking for?
Office Equipment & Supplies Logo

Related Topics:

77 people viewed this question

Ask a Question

Usually answered in minutes!

Top Toshiba Office Equipment & Supplies Experts

didi2005

Level 3 Expert

643 Answers

jasbo
jasbo

Level 3 Expert

2237 Answers

Branko Djurdjevic
Branko Djurdjevic

Level 2 Expert

103 Answers

Are you a Toshiba Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...