In 90% CRT TV circuit, the filament voltage is taken from one among the winding of EHT transformer. The rest, it is taken from the main power supply regulator [SMPS] board. With Sony brand TVs, it is taken from the EHT winding itself. Refer any circuit manual to Sony, to make it understand. If you wish to get some details; check the site linked here. Pull up older posts. Surf the site with patience. http://electronicshelponline.blogspot.com/

Posted on Nov 24, 2014

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Habit-Forming:

    Visited the website for 3 consecutive days.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 79 Answers

Filament winding is one of the few manufacturing processes which allow a high level of automation and process control needed to ensure the required production volume and quality control.
For more details: http://www.cnctechnics.com/

Posted on Jan 22, 2016

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a sony KV-H21M80 telivison proplem is sound come no picture


Check whether the filament of the picture tube glows. If not, check all the solder terminals to CRT base socket. Check the serial resistor connected to the supply voltage to filament. . Check the continuity of filament with a multi-meter.If you are not familiar with electronics, do not attempt to repair! Whether you suffer fatal electrical shock! Instead, contact the nearest service center!

Jan 17, 2013 | Televison & Video

2 Answers

Turn tv on no picture everything else works. turn it off & on a few times maybe more and it comes on and stays on. what could be the problem thanks mike L


Hello,
If everything else works - there is sound and high voltage (static on the screen) - but there is no picture (including no on-screen menus), this limits the likely area of problems is the video output circuitry or CRT filament connections. Check for bad soldering on the CRT ports and around the flyback transformer.

This source of bad connections can result in a variety of erratic symptoms. Check for bad solder connections on the CRT port.

May 28, 2010 | Proview PA-32JK1A 32 in. LCD Television

1 Answer

No filement on rca f36669 pix tube


I assume you have either looked into the rear cover, or removed it. The worst case scenario is an open heater (filament) in the crt itself although this is not real common. If you can use an ohmmeter/continuity tester you can see on the crt pc board which pins are the filaments. Pull the socket off and check for low resistance between these two crt pins if low then odds are the filament is ok. The next thing is to check the solder at the filament connections on the crt board as often you will find "ring cracks" around them and they need re-soldering. The filament circuit is supplied from the IHVT (flyback). Generally with the socket unplugged from the tube you should find low resistance across these two connections also. You read back through the transformer winding if it is ok. If it tests open you may have an open fuse resistor or a bad solder connection at the flyback. The filament (heater) terminals are usually labeled on the main board at the transformer.

Nov 18, 2009 | RCA Televison & Video

1 Answer

Turn on tv, sounds from circuit board but nothing at all on scree


Power supply,horizontal output,fbt transformer or lastly picture tube all this matter can make your ic board got sound

Mar 24, 2009 | Zenith Z27X74W 27" TV

1 Answer

No display


1, cheak the output voltages. filament voltage.
Horizontal transistor.
2. if filament voltage is not comming ,change the filament supply diode, capacitor.

3. incrize the brightnes ( LOT Screen )
4, dry points in neck board.

Dec 15, 2008 | LG Studioworks 563N 15" CRT Monitor

1 Answer

Sound but NO picture


Hello ashleewith2e,

This sounds like a high voltage problem or a picture tube issue (burnt out filament). I would first determine if you had high voltage at the anode of the TV by using a high voltage probe. If you do not have high voltage then I would suspect the voltage doubler, the IHVT (Integrated High Voltage Transformer) or the Horizontal Output Transistor (I doubt this only because you don't have a power supply failure and I would expect this in a modern TV since the high voltage supply is tied to the low voltage supply), the more likely suspect is the voltage doubler. Second possibility I would check is the CRT socket board and CRT filament. Unplug the TV and with a multimeter set to read resistance check to see if the filament pins read a low resistance if so the filament is good. Plug the TV back in and turn it on and check the voltage on the CRT board and compare them to the schematic values. These two tests should localize the issue. Now, If you have a background in electronics, this should be no problem to do, however if you do not have a background in electronics, I would suggest that you have a qualified TV technician troubleshoot and repair this TV set.

I hope this helps,

Thank you,

Shuttle83

http://www.electron-age-technologies-llc.com

Dec 01, 2008 | Sony FD Trinitron WEGA KV-36FS120 36" TV

1 Answer

Monitor No display


1. Power is comming or not.

2.Check Horizontal Transistor.

3. Disply cable. 1,2,3, pins & 13, 14 pins continuty.

4. Filament supply , drypoints in neck board.

5. filament supply diode, capacitor.

Oct 23, 2008 | Samsung SyncMaster 551 15" CRT Monitor

1 Answer

Black picture but the sound works


1. i think filament voltage problem. please cheak the power supply output.

2. dry points on the neck board.

3. filament voltage diode or capacitor bad.

Oct 14, 2008 | Quasar SP-2723 27" TV

1 Answer

RCA 32" TV - Model #32F531T - Faded to black


Isolate filament voltage from CRT,i.e. unplug Crt socket from pix tube.Measure filament voltage on CRT PCB.If present,suspect bad pix tube.If missing,solder any/all connects in filament circuit,meaning CRT board first then main PCB.

Aug 08, 2007 | RCA 32F531T 32" TV

Not finding what you are looking for?
Sony FD Trinitron WEGA KV-27FS100 27" TV Logo

Related Topics:

78 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sony Televison & Video Experts

kakima

Level 3 Expert

102366 Answers

The Knight
The Knight

Level 3 Expert

73698 Answers

Jerry Greenberg
Jerry Greenberg

Level 3 Expert

1667 Answers

Are you a Sony Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...