Question about Ruud UBHC Air Conditioner

Open Question

WHAT IS THE COOLING CAPACITY

MODEL NO.uhbc-21AOONFA

Posted by on

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

What seer and tonnage is a Bryant condenser unit model # 561CJ048 and serial # 4598E06708?


According to the specifications here: http://dms.hvacpartners.com/docs/1009/public/01/pds561c.18.10.pdf , all Bryant 561C air conditioners are 10 SEER. The 048 model has a 4 ton nominal cooling capacity.

I hope this helps.

Cindy Wells

May 04, 2017 | Bryant Heating & Cooling

1 Answer

Hi, my samsung 1hp manual aircon model AWO9P1B, for 2 years it usually drips, but for a month now it does not drip anymore. Its cooling capacity diminish a bit. Is this normal? thanks.


Cooling capacity to dimish is not normal. Have you preformed any service on the unit such as cleaning the coils etc... Its possible that the unit has developed a leak and lost some of the refrigerant.

May 01, 2011 | Heating & Cooling

2 Answers

My model is AEV05KB and recently I see water on the cooling pipes sometimes it drips and sometimes it forms snowlike formations and also if I put the cover on the snow completely coveres the parts inside...


It sounds like the unit is too small for the area being cooled. You should figure the square footage of the area and use this th figure what you need.

Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} Using the square footage and the chart below, determine the correct cooling capacity. Cooling capacity is measured in British thermal units (BTUs) per hour.Area To Be Cooled (square feet) Capacity Needed (BTUs per hour)
100 up to 150 5,000
150 up to 250 6,000
250 up to 300 7,000
300 up to 350 8,000
350 up to 400 9,000
400 up to 450 10,000
450 up to 550 12,000
550 up to 700 14,000
700 up to 1,000 18,000
1,000 up to 1,200 21,000
1,200 up to 1,400 23,000
1,400 up to 1,500 24,000
1,500 up to 2,000 30,000
2,000 up to 2,500 34,000


Make any adjustments for the following circumstances:
If the room is heavily shaded, reduce capacity by 10 percent.
If the room is very sunny, increase capacity by 10 percent.
If more than two people regularly occupy the room, add 600 BTUs for each additional person.
If the unit is used in a kitchen, increase capacity by 4,000 BTUs.
Consider where you install the unit. If you are mounting an air conditioner near the corner of a room, look for a unit that can send the airflow in the right direction.

Jun 17, 2010 | Heating & Cooling

1 Answer

I have a ruud rcha 36a2g heat pump from 2004. What is the seer rating and tonnage of it? Also inscribed uhbc-17jo6nfh


Hi,
The unit is a 3 ton or around 36,000 BTU
It also is around a 10 SEER could be a abit more depending on the maych up of the coil and airhandler or furnace combination...

Heatman101

Apr 15, 2010 | Ruud Matching Split Air Conditioner

1 Answer

Is a model py1pnb036090abaa Payne gas pack large enoug


3 ton cooling capacity 90,000 btu heat capacity. In Vermont it would be enough if the home was a 4 or 5 star home. Remember it is only 80% efficient so you will only net 72,000 btu output.

Mar 09, 2010 | Heating & Cooling

2 Answers

What is the capacity of the cooling system.


long wheel base (with 3rd row seating ) holds 15.2qts.
short wheel base holds 13.9 qts.

Feb 25, 2010 | 2004 Chevrolet TrailBlazer

1 Answer

What is the cooling capacity of a 3 ton air conditioner


Hi, the cooling capacity for 3 tons of cooling is 36,000 B.T.U.'s, For every ton of cooling, you have 12,000 B.T.U's of cooling. I hope this is what you needed to know.
Good Luck,
Shastalaker7

Nov 04, 2009 | Carrier BCA101R Air Conditioner

1 Answer

Replacing the fan motor on RUUD model # UHBC-21J14SFC


remove control make sure make diagram where motor wires go on board. some models have 2 screws to pull out entire blower assemebly

Feb 18, 2009 | Ruud UBHC Air Conditioner

Not finding what you are looking for?
Ruud UBHC Air Conditioner Logo

Related Topics:

54 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ruud Heating & Cooling Experts

Donni Steen

Level 3 Expert

659 Answers

Bill Long

Level 3 Expert

587 Answers

Tim Whalen

Level 3 Expert

3074 Answers

Are you a Ruud Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions