We have an Arctic freezer, 8 years old and the temperature alarm has been sounding for the last fe(w days. We have emptied it and wonder if it fixable. What is the diagnosis! We pulled it out and c

Model 75238-GA1 Product No 922045851 Serial 60305206 We have the corresponding Santo fridge so would love to get this freezer fixed. It started bleeping as temp rose to -12 degrees. We thought we had left the door open but this was not the case. We emptied it and took it out to clean all around the back thinking it might just be dusty. However the temp carried on alarming and although initially dropped to -22 with the turbo on it gradually warmed up. We have switched it off for now but hope you can help. We have the name of local engineer but want to know what the problem may be and if worth fixing. Later Electrolux model is 5cms taller and will not fit the space as sit under to small cupboards in our fitted kitchen.

Posted by on

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 1,169 Answers

It very well be just that the defrost element has quit working. I have numerous frigs where the only problem were these and the owners thought it was a compressor failure. When the defrost quits working the evaporator coil gradually freezes over preventing air flow; therefore, it no cools.

Posted on Nov 08, 2014

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 3,506 Answers

This will require some on site diagnosis as it could be a number of things. If it is a self defroster that circuit could be bad. Otherwsie it could have to do with the tmeprsature control circuit.

Posted on Nov 08, 2014

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 82 Answers

SOURCE: Temperature has dropped from a normal 18 degrees

The only thing that will make it cool to low is a thermostat. They wear out and get out of calibration. Check to be sure the temp sensor from the thermostat is tight on the mount. Its the little tube that connects to the evaporator that makes the thermostat work.

Posted on Jul 01, 2009

  • 2 Answers

SOURCE: My AEG Arctis freezer is not freezing at the

The freezer is probably in need of defrosting. This usually occurs when the freezer has been over packed. It needs to be able to ahve air flow through it, there are holes in the back of the freezer and a defrosting element at the top and they need to be clear in order to keep it frost free. It happend to me and we called an engineer out. solved it by using hair dryer to defrost it.

Posted on Apr 21, 2010

heatman101
  • 43501 Answers

SOURCE: Hi Arctis frost free freezer,almost 4 years

Hi,
As the weather is getting warmer for many people their freezer and/or refrigerator do not work right because of a dirty condenser coil...

Check out this tip that I wrote about that... it is a great place to start trouble shooting your unit...and something that you can do rather then calling a repair person to do a simple thing for you...

http://www.fixya.com/support/r4024657-refrigerator_condenser_coil_cleaning


http://www.fixya.com/support/r3885294-refrigerator_troubleshooting

http://www.fixya.com/support/r4023749-refrigerator_compressor_start_capacitor

heatman101

Posted on May 02, 2010

bobicehouse
  • 1524 Answers

SOURCE: why does my santo electronic fridge ice up

Check gasket on door. Air may be getting in.

Posted on Jul 14, 2010

  • 32 Answers

SOURCE: Temperature increases, even when door is not open.

Unit may be in a defrost mode

Posted on Sep 16, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Error message ,HA on display of Arctic Air AF49


http://www.arcticairco.com/docs/reach-in-owners-manual.pdf PAGE NO. 9

Maximum temperature alarm, Outputs unchanged. I think your board needs to be reseted, but dont do it by your self, look for help.

Regards,

May 25, 2015 | Artic Air Arctic Air AF49 Two Door Reach...

1 Answer

Kenmore upright freezer


order a new seal at the link I provided or ebay or your choice
also check the lid or door adjustmens and obtain specific help instructions at the link I provided
Appliance Repair Help Troubleshooting and Appliance Parts

Apr 08, 2017 | Kenmore Freezers

1 Answer

Temperature alarm sounding. freezer still running & it's only 7/8 years old.


Good Morning Bob, thank you for your post! Did the unit previously experience a power loss? If the temperature of food rises to an unsafe level, the buzzer will sound and the red light, if equipped, will also glow. First, deactivate the alarm to the unit by unplugging it or flipping the household circuit breaker. Wait approximately ten minutes and then turn on the unit. After deactivating the alarm and the unit has run approximately four hours, the red light/alarm should go off on its own. If the red light/alarm continues to stay on, the unit may possibly have a communication problem with the control board, temperature control or a wiring harness. If this is the case, I would recommend connecting with an experienced technician to determine the underlying cause.

Aug 09, 2013 | Frigidaire Commercial 19.53 cu. ft....

1 Answer

The freezer wont go to it's normal temperature and alarm keeps beeping!


either its not defrosting or its low on freon, is there frost anywhere in the freezer, such as the back wall?

Feb 04, 2013 | Freezers

1 Answer

I have arctic air commercial freezer m # F2CW11 s/n# WB338336 freon R134a what psig ? low side and high side when system on


Good day,
When running, the low side is usually about 2 to 4 lbs pressure. The high side is determined by the load and the temperature in the room or area. Minimum 125 lbs. maximum approx. 150 lbs.

Oct 28, 2010 | Arctic Air 22 cu. ft. Commercial Freezer...

1 Answer

I have a Whirlpool side by side fridge freezer (brand new only 2 days old) the alarm is going off and the two lines side by side on the freezer side are flashing?


The alarm is set off when the freezer is out of the differential range of the setpoint. In other words, the freezer is still too warm. If you press the alarm button, the sound will stop but the light will stay on. If the unit is working correctly and cooling properly, this light should go out once the cabinet temperature gets close to the setpoint temperature. Hope this helps you.

Mar 04, 2009 | Freezers

1 Answer

Frigidaire FFU20F9G (model FFU20F9GW3) temperature light is on


Several things could cause this. To check most things you will need to remove the back wall of the freezer to see the evaporator. It is possible the freezer is low on gas. If it is the coils will usually appear to be only half frosted or less. It is possible the defrost is bad ( I assume this is a frost free) In this case the coils will be totally clogged with ice and no air can circulate. If so you'll most likely have to replace the bi-metal... a circular looking part about the diameter of a quarter clipped onto the coil with 2 wires leading from it. This may also cause the fan to stop running from ice accumulation...or the fan itself could be bad which would also cause a partial meltdown. Unless the machine needs gas an appliance repair person will probably charge you around 100 bucks for most of these repairs..gassing it of course will be more and there is no guarantee how long the gas will stay in it as most leaks are difficult, if not impossible to locate. Hope that helps !

Dec 06, 2008 | Frigidaire 20.6 cu. ft. / 583 liter...

2 Answers

Frigidaire FFU20F9G (model FFU20F9GW3) temperature light is on


if the gasket is still sealing allaround the door then u shouldnt be losing any cold. try defrosting the freezer cleaning it out and firing it back up.

Dec 04, 2008 | Frigidaire 20.6 cu. ft. / 583 liter...

1 Answer

13 months old Kenmore compressor very hot.


lacdoi,
huuum At your service!

You said,
The warranty just ran out, Sears came out told me needs a control board ($210 for just labor to replace) not sure about part price. I though a new freezer is about twice his labor and parts, so I sent him away minus $65.
I did some troubleshooting today, pull the plug for 2 days. Plug it in, temp alarm goes on all the time. Turn alarm off, left the freezer running for 4hrs.
Not cold at all, some cool air. Fan is on, compressor is on (can hear humming noise and is vibrating). Compressor is very hot to the touch, could burn finger.
Should I call Sears again, wonder how much to fix all the problem? Or just give up, look for another brand new one (not Kenmore).

MY ADVICE:
Sounds like a big repair bill and multiple problems

How old is the appliance?

If the appliance is 10 years old or more you may not be advisable to put good money into bad!
New appliance are so much more efficient today that they can save you a lot of money in energy!!!!
Replace it.


You will be fine

Bless You huuum

Please give me the best rating for my fine advice before you sign off.
Thank you

Sep 17, 2008 | Kenmore 20.3 cu. ft. / 575 liter Upright...

1 Answer

Freezer will Not Go Below 8 degrees and Alarm keeps sounding


Our manual says it can take our freezer up to 48 hours to get back to the correct temperature. I found that to be the case when we loaded it fully for the first time.

Jun 15, 2008 | Frigidaire Freezers

Not finding what you are looking for?
AEG 10.35 cu. ft. / 293 liter Upright Freezer Arctis A75320GA Logo

186 people viewed this question

Ask a Question

Usually answered in minutes!

Top AEG Freezers Experts

Gil Shultz

Level 3 Expert

3368 Answers

Victor Nwachukwu
Victor Nwachukwu

Level 2 Expert

152 Answers

AJMAL KHAN

Level 2 Expert

382 Answers

Are you an AEG Freezer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...